Energy Monitoring Components: KW2M Eco-Power Meter

Model List

Found 5 matches. Display 1 - 5 matches.
Part No.sort descendingData Sheet[[General specifications]]Supply voltage range[[General specifications]]Rated frequency[[General specifications]]Nominal power consumption[[General specifications]]Inrush current[[General specifications]]Allowable momentary power-off time[[General specifications]]Ambient temperature[[General specifications]]Ambient humidity[[General specifications]]Breakdown voltage(initial)[[General specifications]]Insulation resistance(initial)[[General specifications]]Vibration resistanceParts Inventory
   Column active Filter
Close

Filter by [[General specifications]]Supply voltage range

Column active Filter
Close

Filter by [[General specifications]]Rated frequency

Column active Filter
Close

Filter by [[General specifications]]Nominal power consumption

Column active Filter
Close

Filter by [[General specifications]]Inrush current

Column active Filter
Close

Filter by [[General specifications]]Allowable momentary power-off time

Column active Filter
Close

Filter by [[General specifications]]Ambient temperature

Column active Filter
Close

Filter by [[General specifications]]Ambient humidity

Column active Filter
Close

Filter by [[General specifications]]Breakdown voltage(initial)

Column active Filter
Close

Filter by [[General specifications]]Insulation resistance(initial)

Column active Filter
Close

Filter by [[General specifications]]Vibration resistance

 
design engineersPanasonicAKW263100A
100 to 240V AC50/60 Hz15 VA (240V AC)30 A or less (240V AC at 25℃)10 msOperation: -10 to +50 ℃ 14 to 122 ℉
Storage: -25 to +70 ℃ -13 to 158 ℉
30 to 85% RH (at 20℃ 68℉) with non-condensingBetween the isolated circuits: 2,000 V/1 min
・ Enclosure - All terminals
・ Between primary and secondary insulated circuits (Double insulation is supported)
(1) Power supply terminals - other terminals
(2) Voltage input terminal - other terminals
Between the isolated circuits: 100 MΩ or more10 to 150Hz (7.5 minutes/cycle), Single amplitude: 0.75 mm 0.030 in (1 h on 3 axes)
10 to 55Hz (1 minute/cycle), Single amplitude: 0.375 mm 0.015 in (1 h on 3 axes)
design engineersPanasonicAKW272100A
100 to 240V AC50/60 Hz15 VA (240V AC)30 A or less (240V AC at 25℃)10 msOperation: -10 to +50 ℃ 14 to 122 ℉
Storage: -25 to +70 ℃ -13 to 158 ℉
30 to 85% RH (at 20℃ 68℉) with non-condensingBetween the isolated circuits: 2,000 V/1 min
・ Enclosure - All terminals
・ Between primary and secondary insulated circuits (Double insulation is supported)
(1) Power supply terminals - other terminals
(2) Voltage input terminal - other terminals
Between the isolated circuits: 100 MΩ or more10 to 150Hz (7.5 minutes/cycle), Single amplitude: 0.75 mm 0.030 in (1 h on 3 axes)
10 to 55Hz (1 minute/cycle), Single amplitude: 0.375 mm 0.015 in (1 h on 3 axes)
design engineersPanasonicAKW274240A
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicAKW264100A
100 to 240V AC50/60 Hz15 VA(240 V AC)30 A or less (240 V AC at 25 ℃)10ms・Operation : -10 to +50 ℃ 14 to 122 ℉
・Storage : -25 to +70 ℃ -13 to 158 ℉
30 to 85% RH (at 20 ℃ 68 ℉) with non-condensing・Between the isolated circuits : 2,000 V/1 min
• Enclosure - All terminals
• Between primary and secondary insulated circuits (Double insulation is supported)
(1) Power supply terminals - other terminals
(2) Voltage input terminal - other terminals
Between the isolated circuits : 100 MΩ or more・10 to 150 Hz (7.5 minutes/cycle)
Single amplitude : 0.75 mm 0.030 in (1 h on 3 axes)
・10 to 55 Hz (1 minute/cycle)
Single amplitude : 0.375 mm 0.015 in (1 h on 3 axes)
design engineersPanasonicAKW273230A
n/an/an/an/an/an/an/an/an/an/a