Human Machine Interface (HMI): GT703

Model List

Found 16 matches. Display 1 - 15 matches.
Part No.sort descendingData SheetCE marking directive compliancePower supplyCommunication portOperating voltage rangePower consumptionPower supply unit isolation methodAmbient temperatureAmbient humidityStorage temperatureStorage humidityParts Inventory
   Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Power supply

Column active Filter
Close

Filter by Communication port

Column active Filter
Close

Filter by Operating voltage range

Column active Filter
Close

Filter by Power consumption

Column active Filter
Close

Filter by Power supply unit isolation method

Column active Filter
Close

Filter by Ambient temperature

Column active Filter
Close

Filter by Ambient humidity

Column active Filter
Close

Filter by Storage temperature

Column active Filter
Close

Filter by Storage humidity

 
design engineersPanasonicAIG703WMN1B2
EMC Directive, RoHS Directive24 V DCRS-232C21.6 ~ 26.4 V DC2.4 W or lessTransformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WMNMS5
EMC Directive, RoHS Directive5V DCRS-422/RS-4854.5 ~ 5.5 V DC2 W or less
(※): Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WGN1B2
EMC Directive, RoHS Directive24 V DCRS-232C21.6 ~ 26.4 V DC2.4 W or lessTransformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WGNMS2
EMC Directive, RoHS Directive24 V DCRS-422/RS-48521.6 ~ 26.4 V DC2.4 W or lessTransformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WMN1S2
EMC Directive, RoHS Directive24 V DCRS-232C21.6 ~ 26.4 V DC2.4 W or lessTransformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WMNMS2
EMC Directive, RoHS Directive24 V DCRS-422/RS-48521.6 ~ 26.4 V DC2.4 W or lessTransformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WGN1S5
EMC Directive, RoHS Directive5V DCRS-232C4.5 ~ 5.5 V DC2 W or less
(※): Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WGNMB2
EMC Directive, RoHS Directive24 V DCRS-422/RS-48521.6 ~ 26.4 V DC2.4 W or lessTransformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WMN1B5
EMC Directive, RoHS Directive5V DCRS-232C4.5 ~ 5.5 V DC2 W or less
(※): Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WMNMB2
EMC Directive, RoHS Directive24 V DCRS-422/RS-48521.6 ~ 26.4 V DC2.4 W or lessTransformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WGN1S2
EMC Directive, RoHS Directive24 V DCRS-232C21.6 ~ 26.4 V DC2.4 W or lessTransformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WGNMB5
EMC Directive, RoHS Directive5V DCRS-422/RS-4854.5 ~ 5.5 V DC2 W or less
(※): Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WGNMS5
EMC Directive, RoHS Directive5V DCRS-422/RS-4854.5 ~ 5.5 V DC2 W or less
(※): Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WMNMB5
EMC Directive, RoHS Directive5V DCRS-422/RS-4854.5 ~ 5.5 V DC2 W or less
(※): Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
design engineersPanasonicAIG703WGN1B5
EMC Directive, RoHS Directive5V DCRS-232C4.5 ~ 5.5 V DC2 W or less
(※): Power cannot be supplied from TOOL port of PLC (CPU unit).
Transformer isolation0 to +50 ℃ +32 to +122 ℉20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)-20 to +60 ℃ -4 to +140 ℉10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)

Pages