Specification

Specifications table for model AFP0RC10MRS
ItemPerformance characteristics
gramming method / Control methodRelay symbol / Cyclic operation
Number of I/O points : No expansion (Control unit only)10 points
[Input : 6,
Relay output : 4]
Number of I/O points : With expansion 1
Same type of control and expansion units
Max. 58 points (Note: For the limitations while operating units, reter to the manual.)
Number of I/O points : With expansion 2
Mix type of relay and transistor units
Max. 106 points (Note: For the limitations while operating units, reter to the manual.)
gram memoryEEPROM (no backup battery required)
gram capacity16 k steps
Number of instructions : Basic110 approx.
Number of instructions : High-level210 approx.
Operation speed : Up to 3,000 stepsBasic instructions : 0.08 μs min. Timer instructions : 2.2 μs min.
High-level instructions : 0.32 μs (MV instruction) min.
Operation speed : 3,001st and later stepsBasic instructions : 0.58 μs min. Timer instructions : 3.66 μs min.
High-level instructions : 1.62 μs (MV instruction) min.
Operation memory : Relay : Internal relay (R)4,096 points
Operation memory : Relay : Timer / Counter (T / C)1,024 points
Operation memory : Memory area : Data register (DT)12,315 words
Operation memory : Memory area : Index register (IX, IY)14 words (IO to ID)
Master control relay points (MCR)256 words
Number of labels (JMP and LOOP)256 labels
Differential pointsEquivalent to the program capacity
Number of step ladder1,000 stages
Number of subroutines500 subroutines
Special functions : High speed counterSingle-phase: 6 points (50 kHz max. each) 2-phase: 3 channels (15 kHz max. each) (Note: For the limitations while operating units, reter to the manual.)
Special functions : Pulse outputNot available
Special functions : PWM outputNot available
Special functions : Pulse catch input / interrupt inputTotal 8 points (with high speed counter)
Special functions : Interrupt programInput : 8 programs (6 programs for C10 only)
/ Periodic : 1 program / Pulse match : 4 programs/td>
Special functions : Periodical interruptIn units of 0.5 ms : 0.5 ms to 1.5 sec. / In units of 10 ms : 10 ms to 30 sec.
Special functions : Constant scanIn units of 0.5 ms : 0.5 ms to 600 ms
Special functions : RS485 portOne RS485 port is mounted (3P terminal block)
Transmission speed (Baud rate) : 115.2 kbps (It is possible to change to 19.2 kbps by the setting.), Transmission distance : 1,200 m 3,937 ft, Communication method : half duplex
Maintenance : Memory backup : Program and system registerStored program and system register in EEPROM
Maintenance : Memory backup : Operation memoryStored fixed area in EEPROM
Counter : 16 points
Internal relay : 128 points
Data register : 315 words
Maintenance : Self-diagnostic functionWatchdog timer (690 ms approx.), Program syntax check
Maintenance : Real-time clock functionNot available
Maintenance : Other functionsRewriting in RUN mode, Download in RUN mode (incl. comments),
8-character password setting, and Program upload protection
Rated voltage24 V DC
Operating voltage range20.4 to 28.8 V DC
Allowed Momentary Power Off Time5 ms (at 20.4 V DC), 10 ms (21.6 V DC or higher)
Operating Temperature0 to +55 ℃ 32 to +131 ℉
Storage temperature-40 to +70 ℃ -40 to +158 ℉ (-20 ℃ to +70 ℃ -4 to +158 ℉ for T32 only)
Operating humidity10 to 95% RH (at 25 ℃ 77 ℉, no condensation)
Storage humidity10 to 95% RH (at 25 ℃ 77 ℉, no condensation)
Breakdown Voltage (Detection Current: 5 mA)Input terminals - output terminals, Output terminals - power and functional ground terminals --- Transistor output : 500 V AC for 1 minute (Relay output : 1,500 V AC for 1 minute) /
Input terminals - power and functional ground terminals, Functional ground terminal - power terminal --- Transistor output : 500 V AC for 1 minute (Relay output : 500 V AC for 1 minute) /
Output terminals - output terminals (different common terminals) --- Relay output : 1,500 V AC for 1 minute
Insulation resistance (Test voltage: 500 V DC)Input terminals - output terminals, input terminals - power and functional ground terminals, output terminals - power and functional ground terminals, functional ground terminal - power terminal --- Transistor output : 100 MΩ minimum (relay output : 100 MΩ minimum) /
Output terminals - output terminals (different common terminals) --- Relay output : 100 MΩ minimum
Vibration resistance5 to 9 Hz, single amplitude of 3.5 mm, 1 sweep/min; 9 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min; for 10 min each in X, Y, and Z directions
Shock resistance147 m/s2 or more , 4 times each in X, Y, and Z directions
Noise immunity1,000 V (p-p) with pulse widths 50 ns and 1 μs (using a noise simulator)(Power supply terminal)
Operating environmentFree from corrosive gasses and excessive dust
Rated input voltage24 V DC
Applied Voltage Range21.6 to 26.4 V DC
Rated input current2.6 mA approx. (at 24 V DC)
mpedance9.1 kΩ approx.
r common2 points / common + 1 point / common + 1point / comon
Min. ON voltage/Min. ON current19.2 V / 2 mA
Response time : OFF→ON10 ms approx.
Response time : ON→OFF8 ms approx.
lation methodPhotocoupler
RemarkSince the response time of X0 to X7 is very fast (for high-speed counter input) the FP0 happens to chattering noise as an input signal. To prevent this, it is recommended that the timer should be put in the ladder program.
ype1a
Rated control capacity2 A 250 V AC, 2 A 30 V DC (4.5 A / common)
Life time : Mechanical2 x 107 operations or more
Life time : Electrical105 operations or more
Surge absorberNone

Stock Check

Stock check for product AFP0RC10MRS
DistributorQuantityInventory Date
Digi-Key Electronics
United States
Tel. 1-800-344-4539
108/20/2019

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.

What's New

Stay up to date