Item | Performance characteristics |
---|---|
Supply Voltage Range | 100 to 240V AC |
Rated Frequency | 50/60 Hz |
Nominal Power Consumption | 15VA approx. (240V AC at 25 ℃ +77 ℉) |
Inrush Current | 30A or less (240V AC/DC at 25 ℃ +77 ℉) |
Allowable Momentary Power-Off Time | 10 ms |
Ambient Temperature | Operation: at -10 to +50 ℃ 14 to 122 ℉ Storage: at -25 to +70 ℃ -13 to 158 ℉ |
Ambient Humidity | 30 to 85% RH (at 20℃ 68℉) with non-condensing |
Breakdown Voltage (Initial) | Between the isolated circuits: 2,000 V/1 min ・ Enclosure - All terminals ・ Between primary and secondary insulated circuits (Double insulation is supported) (1) Power supply terminals - other terminals (2) Voltage input terminal - other terminals |
Insulation Resistance (Initial) | Between the isolated circuits: 100 MΩ or more |
Vibration Resistance | 10 to 150Hz (7.5 minutes/cycle), Single amplitude: 0.75 mm 0.030 in (1 h on 3 axes) 10 to 55Hz (1 minute/cycle), Single amplitude: 0.375 mm 0.015 in (1 h on 3 axes) |
Shock Resistance | Min. 294 m/s2 (5 times on 3 axes) |
Display Method | Black-and-white LCD with backlight (graphic form) |
Display Updating Time Cycle | 500, 1000, 2000, 3000 ms (set with setting mode) |
Power Failure Memory Method | Internal memory |
Sea Level Altitude | Under 2,000 m 6,562 ft |
Overvoltage Category | III |
Pollution Degree | 2 |
Dimensions W/H/D | 85 x 70 x 65 mm 3.346 x 2.756 x 2.559 in |
Weight (Typ.) | Approx. 200 g |