Item | Performance characteristics |
---|---|
CE Marking Compliant Directives | EMC Directive, RoHS Directive |
Effective Charge Removal Width | 50 mm 1.969 in approx. |
Charge Removal Time | 0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2) (Note 1: Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and air supply 60 ℓ / min. (0.3 MPa)) . (Note 2: Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
Ion Balance | ±30 V or less (Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.) (Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.) |
Discharge Method | Pulse AC method (Note:The discharge frequencies of 50 Hz, 20 Hz are accepted.) |
Discharge Frequency | 50 Hz / 20 Hz |
Discharge Output Voltage | ±7,000 V approx. |
Maximum Air Pressure | 0.5 MPa |
Ozone Generation | 0.01 ppm or less (Note:Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
Applicable Fluid | Air (dried clean air) (Note:The dried clean air is the air dried (dew point: equivalent of -20 ℃ -4 ℉) and filtered (mesh-size: equivalent of 0.01 μm) .) |
Operating Altitude | 2,000 m 6561.68 ft or less (Note:Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.) |
Ambient Temperature | 0 to +40 ℃ +32 to +104 ℉ (No dew condensation), Storage: -10 to +65℃ +14 to +149℉ |
Ambient Humidity | 35 to 65 % RH, Storage: 35 to 85 % RH |
Vibration Resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each |
Enclosure Earthing | Floating |
Material | Main unit enclosure: Stainless steal (SUS) Head mounting bracket: Stainless steal (SUS) Discharge needle: PFA, Tungsten |
Weight (Typ.) | Net weight : 370 g approx. |
Length of High-Voltage Cable | 1.2 m 3.937 ft |
Accessories | Head mounting bracket (installed at the time of factory shipment) |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.