Specification

Specifications table for model ER-VS02
ItemPerformance characteristics
CE Marking Compliant DirectivesEMC Directive, RoHS Directive
Charge Removal Time1 sec. or less (plus or minus1,000 V to plus or minus100 V)
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Ion Balanceplus or minus10 V or less
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Ozone Generation0.03 ppm or less
(Note) A typical sample applied with a power voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use.
Applicable FluidAir (dried clean air)
(Note) The air is dried (dew point: equivalent of –20 ℃ – 4 ℉) and filtered (mesh-size: equivalent of 0.01 microm 0.0004 mil) air.
Supplied Air Flow 500 liter/min. (ANR) or less
(Note) The applicable pressure range depends on the nozzle to be used.
Air Pressure Range0.05 to 0.7 MPa
(Note) The applicable pressure range depends on the nozzle to be used.
Supply Voltage 24 V DC plus or minus10 %
Current Consumption70 mA or less
Discharge MethodHigh frequency AC method
Discharge Output Voltage2,000 V approx.
Check Output (CHECK)NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between check output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
Check Output: Output OperationON when a dirt or worn etc. of the discharge needle is detected for 1.5 sec. or more continuously, OFF when operation is normal
(Note) When confirming the check output, carry out discharge for 2 sec. or more.
Check Output: Short-Circuit ProtectionIncorporated
Error OutputNPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between error output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
Error Output: Output OperationOFF when abnormal discharge is detected, ON when operation is normal
Error Output: Short-Circuit ProtectionIncorporated
Discharge Halt Input (DSC OFF)Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start)
(Note: ”DSC” is an abbreviated name of ”DISCHARGE”.)
Reset Input When abnormal discharge is detected, discharge is halted due to an error. Reset the discharge halt by briefly shorting the
power supply’s 0 V line.
Indicators: Power Green LED (lights up when the power is ON)
Indicators: Discharge (DSC)Green LED (lights up when discharging)
(Note: ”DSC” is an abbreviated name of ”DISCHARGE”.)
Indicators: Check Orange LED (lights up when the discharge needle is worn or dirty, etc.)
(Note) When confirming the check output, carry out discharge for 2 sec. or more.
Indicators: Error (Error)Red LED (lights up when abnormal discharge is detected)
Ambient Temperature0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed)
Ambient Humidity35 to 65 % RH
Vibration Resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
CableCable with a connector, 0.5 m 1.640 ft long
MaterialEnclosure: PPS, Cover: Stainless steel, Discharge needle: Tungsten
Weight (Typ.)Net weight: 120 g approx.
AccessoriesConnector for wiring: 1 set [Manufactured by Molex: Housing (5557-08R), Terminal (5556TL)]