Specification

Specifications table for model EC-B01-EX
ItemPerformance characteristics
CE Marking Compliant DirectivesEMC Directive, RoHS Directive
Charge Removal Time0.5 sec. approx. or less (plus or minus1,000 V to plus or minus100 V)
(Note:Typical value at 100 mm 3.937 in from the front of air outlet at an applied air pressure of 0.50 MPa.)
Ion Balanceplus or minus10 V or less
Applicable FluidAir (dried clean air)
Supplied Air Flow Max. 300 liter/min. (ANR) or less
Air Pressure Range0.05 to 0.50 MPa
Supply Voltage Accessory AC adapter (Note:INPUT: 100-240 V AC plus or minus10 % 50/60 Hz
(OUTPUT: 24 V DC))
(Note:Please prepare an AC cable separately as it is needed.
The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL))
Power Consumption80 VA or less
Timer Mode2 sec. / 5 sec. / 10 sec. / synchronized with sensor or with external input selectable by switch
Pulse Air Mode Pulse 1 (long) / Pulse 2 (short) / OFF (continuous) selectable by switch
Ambient Temperature0 to +40 ℃ +32 to +104 ℉
Ambient Humidity35 % to 65 % RH (No dew condensation)
Weight (Typ.)Main body: 6.5 kg approx.
AccessoriesAC adapter: 1pc., Filter: 1pc., Protective mesh: 1pc.

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.

What's New