Item | Performance characteristics |
---|---|
CE Marking Compliant Directives | EMC Directive, RoHS Directive |
Charge Removal Time | 0.5 sec. approx. or less (plus or minus1,000 V to plus or minus100 V) (Note:Typical value at 100 mm 3.937 in from the front of air outlet at an applied air pressure of 0.50 MPa.) |
Ion Balance | plus or minus10 V or less |
Applicable Fluid | Air (dried clean air) |
Supplied Air Flow | Max. 300 liter/min. (ANR) or less |
Air Pressure Range | 0.05 to 0.50 MPa |
Supply Voltage | Accessory AC adapter (Note:INPUT: 100-240 V AC plus or minus10 % 50/60 Hz (OUTPUT: 24 V DC)) (Note:Please prepare an AC cable separately as it is needed. The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)) |
Power Consumption | 80 VA or less |
Timer Mode | 2 sec. / 5 sec. / 10 sec. / synchronized with sensor or with external input selectable by switch |
Pulse Air Mode | Pulse 1 (long) / Pulse 2 (short) / OFF (continuous) selectable by switch |
Ambient Temperature | 0 to +40 ℃ +32 to +104 ℉ |
Ambient Humidity | 35 % to 65 % RH (No dew condensation) |
Weight (Typ.) | Main body: 6.5 kg approx. |
Accessories | AC adapter: 1pc., Filter: 1pc., Protective mesh: 1pc. |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.