Static Control Devices: Bench Top Ionizer Cleaning Box EC-B

Model List

Found 2 matches. Display 1 - 2 matches.
Part No.sort descendingData SheetCE marking compliant directivesCharge removal timeIon balanceApplicable fluidSupplied air flowAir pressure rangeSupply voltagePower consumptionTimer modePulse air modeParts Inventory
   Column active Filter
Close

Filter by CE marking compliant directives

Column active Filter
Close

Filter by Charge removal time

Column active Filter
Close

Filter by Ion balance

Column active Filter
Close

Filter by Applicable fluid

Column active Filter
Close

Filter by Supplied air flow

Column active Filter
Close

Filter by Air pressure range

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Power consumption

Column active Filter
Close

Filter by Timer mode

Column active Filter
Close

Filter by Pulse air mode

 
design engineersPanasonicEC-B01-EX
EMC Directive, RoHS Directive0.5 sec. approx. or less (plus or minus1,000 V to plus or minus100 V)
(Note:Typical value at 100 mm 3.937 in from the front of air outlet at an applied air pressure of 0.50 MPa.)
plus or minus10 V or lessAir (dried clean air)Max. 300 liter/min. (ANR) or less0.05 to 0.50 MPaAccessory AC adapter (Note:INPUT: 100-240 V AC plus or minus10 % 50/60 Hz
(OUTPUT: 24 V DC))
(Note:Please prepare an AC cable separately as it is needed.
The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL))
80 VA or less2 sec. / 5 sec. / 10 sec. / synchronized with sensor or with external input selectable by switchPulse 1 (long) / Pulse 2 (short) / OFF (continuous) selectable by switch
design engineersPanasonicec-b02-ex
EMC Directive, RoHS Directive0.5 sec. approx. or less (plus or minus1,000 V to plus or minus100 V)
(Note:Typical value at 100 mm 3.937 in from the front of air outlet at an applied air pressure of 0.50 MPa.)
plus or minus10 V or lessAir (dried clean air)Max. 500 liter/min. (ANR) or less0.05 to 0.50 MPaAccessory AC adapter (Note:INPUT: 100-240 V AC plus or minus10 % 50/60 Hz
(OUTPUT: 24 V DC))
(Note:Please prepare an AC cable separately as it is needed.
The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL))
90 VA or less2 sec. / 5 sec. / 10 sec. / synchronized with sensor or with external input selectable by switchPulse 1 (long) / Pulse 2 (short) / OFF (continuous) selectable by switch