UV-Curing Systems: Aicure UP50 Lamp Spot Type

Model List

Found 1 matches. Display 1 - 1 matches.
Part No.sort descendingData SheetPower supplyLamp:Lamp Product No.LampUV irradiationShutterSettingExternal signal:InputExternal signal:OutputDimensionsWeightParts Inventory
   Column active Filter
Close

Filter by Power supply

Column active Filter
Close

Filter by Lamp:Lamp Product No.

Column active Filter
Close

Filter by Lamp

Column active Filter
Close

Filter by UV irradiation

Column active Filter
Close

Filter by Shutter

Column active Filter
Close

Filter by Setting

Column active Filter
Close

Filter by External signal:Input

Column active Filter
Close

Filter by External signal:Output

Column active Filter
Close

Filter by Dimensions

Column active Filter
Close

Filter by Weight

 
design engineersPanasonicANUP50
90 to 264 V AC 50/60 Hz 280 V AANUPS204200 W mercury xenon lamp, preset quickly-attachable type
* Average life of 3,000 hours: Ratio to the initial UV intensity --
80% or higher in a vertical position, 70% or higher in a horizontal
position (when the auto control function is off)
* Guaranteed life: 2,000 hours
UV intensity adjustment by digital setting (0 to 100%, in increments of 0.5%)
UV auto control
Programmable irradiation (10 steps in each of 10 patterns)
External signal control: Turning the lamp on/off, manual opening/closing
of the shutter, starting programmed pattern irradiation, starting
timer-controlled irradiation, and executing calibration
Electronically-controlled shutter using manual or timer-controlled operationDigital setting using membrane switchesOpening/closing the shutter (timer/manual), lighting the lampLighting the lamp, stabilizing the lamp light, opening the shutter,
outputting error signals, and indicating the lamp life
165 x 201 x 325 mm 6.496 x 7.913 x 12.795 in (Excluding protruding sections)8 kg approx.