UV-Curing Systems: LED Line Type UV Curing System Aicure UD40

Model List

Found 54 matches. Display 1 - 15 matches.
Part No.sort descendingData SheetNo. of blocksPerformance : Light sourcePerformance : Peak irradiation intensity : Irradiation distance: 10 mm 0.394 inPerformance : Peak irradiation intensity : Irradiation distance: 30 mm 1.181 inPerformance : Effective irradiation width : Irradiation distance: 10 mm 0.394 inPerformance : Effective irradiation width : Irradiation distance: 30 mm 1.181 inPerformance : Estimated life expectancyEnvironment : Ambient operating temperature/ Ambient operating humidityEnvironment : Storage temperature / Storage humidityEnvironment : Cooling systemParts Inventory
   Column active Filter
Close

Filter by No. of blocks

Column active Filter
Close

Filter by Performance : Light source

Column active Filter
Close

Filter by Performance : Peak irradiation intensity : Irradiation distance: 10 mm 0.394 in

Column active Filter
Close

Filter by Performance : Peak irradiation intensity : Irradiation distance: 30 mm 1.181 in

Column active Filter
Close

Filter by Performance : Effective irradiation width : Irradiation distance: 10 mm 0.394 in

Column active Filter
Close

Filter by Performance : Effective irradiation width : Irradiation distance: 30 mm 1.181 in

Column active Filter
Close

Filter by Performance : Estimated life expectancy

Column active Filter
Close

Filter by Environment : Ambient operating temperature/ Ambient operating humidity

Column active Filter
Close

Filter by Environment : Storage temperature / Storage humidity

Column active Filter
Close

Filter by Environment : Cooling system

 
design engineersPanasonicANUD4B411
4385 nm ± 10 nm 0.015 mil ± 0.0004 mil4,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
252 mm 9.921 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
232 mm 9.134 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4B511
5385 nm ± 10 nm 0.015 mil ± 0.0004 mil4,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
324 mm 12.756 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
304 mm 11.968 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4A111
1365 nm ± 10 nm 0.014 mil ± 0.0004 mil4,200 mW/cm2 (Wavelength: 365 nm 0.014 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,300 mW/cm2 (Wavelength: 365 nm 0.014 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
36 mm 1.417 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
16 mm 0.630 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4A411
4365 nm ± 10 nm 0.014 mil ± 0.0004 mil4,200 mW/cm2 (Wavelength: 365 nm 0.014 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,300 mW/cm2 (Wavelength: 365 nm 0.014 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
252 mm 9.921 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
232 mm 9.134 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4A511
5365 nm ± 10 nm 0.014 mil ± 0.0004 mil4,200 mW/cm2 (Wavelength: 365 nm 0.014 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,300 mW/cm2 (Wavelength: 365 nm 0.014 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
324 mm 12.756 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
304 mm 11.968 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4A611
6365 nm ± 10 nm 0.014 mil ± 0.0004 mil4,200 mW/cm2 (Wavelength: 365 nm 0.014 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,300 mW/cm2 (Wavelength: 365 nm 0.014 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
396 mm 15.591 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
376 mm 14.803 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4B111
1385 nm ± 10 nm 0.015 mil ± 0.0004 mil4,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
36 mm 1.417 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
16 mm 0.630 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4B211
2385 nm ± 10 nm 0.015 mil ± 0.0004 mil4,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
108 mm 4.252 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
88 mm 3.465 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4B311
3385 nm ± 10 nm 0.015 mil ± 0.0004 mil4,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
180 mm 7.087 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
160 mm 6.299 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4B611
6385 nm ± 10 nm 0.015 mil ± 0.0004 mil4,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company’s measurement standards. Values are initial guaranteed values, but not representative values.
2,600 mW/cm2 (Wavelength: 385 nm 0.015 mil)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
396 mm 15.591 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
376 mm 14.803 in
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
15,000 hours (70% for initial UV intensity)
(Note)Based on our company's measurement standards. Values are typical, but not guaranteed.
0 to +35 ℃ 32 to +95 ℉ / 30 to 85% RH (No dew condensation allowed)-10 to +60 ℃ -50 to +140 ℉ / 30 to 85% RH (No dew condensation or icing allowed)Fan-forced air cooling
design engineersPanasonicANUD4S11
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicANUD4S12
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicANUD4S13
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicANUD4S14
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicANUD4S15
n/an/an/an/an/an/an/an/an/an/a

Pages