Part Number List

Results 10
Models table for series Communication Unit for Open Network SC-GU3
Part No.DatasheetDirective complianceNumber of connectable unitsSupply voltageCurrent consumptionAllowable Passing CurrentCommunication MethodNumber of occupied stationBaud Rate / Total Extension LengthCommunication CableStation No. settingRemote station typeAmbient TemperatureAmbient HumidityMaterialWeight (Typ.)Compliance StandardBaud RateInternodal distanceCommunication PortsEtherCAT communication standardsPower indicatorAddress SettingSupported functions
EMC Directive, RoHS Directive
Maximum of 16 units per SC-GU3-01 unit
(Max. 12 units when FX-500 / LS-500 series are connected) (Max. 12 units when FX-500 / LS-500 series are connected)
24V DC +10/-15% Ripple P-P 10 % or less
120 mA or less (without connected sensor amplifiers)
Wire-saving connector 2 A (Note 1), supply connector 6 A (Note 2)
(Note 1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
(Note 2) In case of supplying power to other devices, be sure to set the current less than allowable passing current.
CC-Link Ver.1.10
Switchable 1 or 4 station
10Mbps / 100m 328.084 ft
5Mbps / 150m 492.126 ft
2.5Mbps / 200m 656.168 ft
625kbps / 600m 1968.504 ft
156kbps / 1,200m 3937.008 ft
Specified cable (twist pair cable with shield)
(Note) Use only a special-use communication cable that is approved by the CC-Link Partner Association.
1 to 64 (0 and 65 or more: Error)
Remote device station
–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Enclosure: Polycarbonate
Net weight: 80 g approx.
Gross weight: 120 g approx.
EMC Directive, RoHS Directive
Maximum of 16 units per SC-GU3-01 unit
(Max. 12 units when FX-500 / LS-500 series are connected)
24 V DC plus or minus 10 % Ripple P-P 10 % or less
80 mA or less (at 24 V) (without connected sensor amplifiers)
Wire-saving connector 2 A
(Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
Category 5e
–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Enclosure: Polycarbonate
Net weight: 75 g approx.
Gross weight: 120 g approx.
IEEE802.3u
100 Mbps
100 m 328.1ft
RJ45 × 2
Process data communication, Mailbox communication
1 unit for 1 communication unit
11 to 25 V DC Ripple P-P 10 % or less
25 mA or less
–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Enclosure: Polycarbonate
Net weight: 20 g approx.
Gross weight: 20 g approx.
Green LED (lights up when the power is ON)
EMC Directive, RoHS Directive
Maximum of 16 units per SC-GU3-02 unit
(Max. 12 units when FX-500 / LS-500 series are connected) (Max. 12 units when FX-500 / LS-500 series are connected)
11 to 25 V DC Ripple P-P 10 % or less
100 mA or less (without connected sensor amplifiers)
Wire-saving connector 2A
(Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
DeviceNet compliant
500kbps / 100m 328.084 ft (thick cable) 100m 328.084 ft (thin cable)
250kbps / 250m 820.21 ft (thick cable) 100m 328.084 ft (thin cable)
125kbps / 500m 1640.42 ft (thick cable) 100m 328.084 ft (thin cable)
Complies with DeviceNet standards
(Note) Use a special cable for DeviceNet that complies with the DeviceNet standards.
–10 to +55 ℃ +14 to +131 ℉ (No dew ondensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Enclosure: Polycarbonate
Net weight: 75 g approx.
Gross weight: 120 g approx.
0 to 63 (64 or more: Error)
I/O communication (Poll), Explicit message communication
Max. 16 units per 1 communication unit
-10 to +55degrees +14 to +131degrees Fahrenheit (If 4 to 7 units are connected in cascade: -10 to +50degrees +14 to +122degrees Fahrenheit , if 8 to 16 units are connected in cascade: -10 to +45degrees +14 to +113degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -20 to +70degrees - 4 to +158degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Enclosure: Polycarbonate
Metal plate: Aluminum
Net weight: 10 g approx.
Gross weight: 25 g approx.