Part Number List

Results 70
Models table for series Ultra High-speed・High-precision Laser Displacement Sensor HL-C2
Part No.DatasheetConnectale sensor headSupply voltageCurrent consumptionSampling rateAnalog Output : VoltageAnalog Output: CurrentAlarm OutputAlarm Output : Output OperationAlarm Output : Short-Circuit ProtectionJudgment output (HI, GO, LO)Judgment output (HI, GO, LO): Output operationJudgment output (HI, GO, LO) : Short-circuit protectionStrobe outputStrobe output : Output operationStrobe output : Short-circuit protectionRemote interlock inputLaser control inputZero Set InputTiming inputReset inputMemory change inputIndicator : PowerIndicator : Sensor head A Laser radiationIndicator : Sensor head B Laser radiationIndicator : Alarm 1Indicator : Alarm 2Environmental resistance : Ambient temperatureEnvironmental resistance : Ambient humidityEnvironmental resistance : Vibration resistanceEnvironmental resistance : Shock resistanceMaterialWeight (Typ.)AccessorySetup modeMeasurement center distanceMeasuring rangeResolution [Average number of samples]LinearityTemprerature characteristicsLight sourceBeam DiameterReceiving elementIndicator : Laser emissionIndicator : Measuring rangeEnvironmental resistance : ProtectionEnvironmental resistance : Ambient illuminanceCableCable Extension
Number of connectable units: Max. 2 units.
24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
500 mA approx. at 2 sensor heads connected
350 mA approx. at 1 sensor head connected
(100 mA approx. is additionally required when the mini console is connected)
10 micro s, 20 micro s, 40 micro s, 100 micro s, 200 micro s, 400 micro s, 1 ms, 2 ms
Voltage output scale: -5 to +5 V/F.S (initial value)
Output range during normal status: -10.0 to +10.0 V
Output at abnormal status: -10.8 V or +10.8 V
Resolution: 2 mV, Linearity: plus or minus 0.05 % F.S.
Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx.
(Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Current output scale: 4 to 20 mA/F.S (initial value)
Output range during normal status: 2 to 24 mA
Output at abnormal status: 1 mA or 25 mA
Resolution: 3 micro A, Linearity plus or minus 0.05% F.S.
Load impedance: 250 Ohm max., Response delay time: 10 micro s approx.
(Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less[between alarm output and Common(-)]
- Residual voltage: 1 V or less(at 100 mA sink current)
Opened when the amount of light is insufficient
Incorporated
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less[between judgment output to Common(-)]
- Residual voltage: 1 V or less(at 100 mA sink current)
Opened at output operation
Incorporated
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less[between strobe output to Common(-)]
- Residual voltage: 1 V or less(at 100 mA sink current)
Opened at data determination
Incorporated
Laser emission is delayed when connected to Common (-).
Laser emission stop at open
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Laser emission is stopped when connected to Common (-).
Laser is emitted immediately after opened.
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Zero set is ON when connected with Common (-).
Zero set turns to OFF after continuously connected to Common (-) for one second.
Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
ON at/during connection to Common (-)(depending on analysis mode)
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Reset is done when connected to Common (-).
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Memory is specified when connected to Common (-).
Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Green LED (lights up at power on)
Green LED (lights up during or immediately before laser emission of sensor head A)
Green LED (lights up during or immediately before laser emission of sensor head B)
Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 %RH
10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Case: Polycarbonate
450 g approx.
CD-ROM: 1 pc.
USB cable (2 m 6.562 ft long): 1 pc.
Short bracket: 1 pc.
0 to +45 degrees +32 to +113 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X,Y and Z directions for two hours each
196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Enclosure: Die-cast aluminum
Case cover: Die-cast aluminum
Front cover: Glass
250 g approx. (including cable)
English warning label: 1 set [The FDA regulations conforming type includes a set of both the IEC label (written in English) and JIS label (written in Japanese)].
Diffuse reflective
Specular reflective
Diffuse reflective: 30 mm 1.181 in
Specular reflective: 26.4 mm 1.039 in
Diffuse reflective: plus or minus 5 mm plus or minus 0.197 in
Specular reflective: plus or minus 4.6 mm plus or minus 0.181 in
(Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows.
[Diffuse reflective]
20 micro s: 0 to +5.0 mm 0 to +0.197 in
10 micro s: +3.8 to +5.0 mm +0.150 to +0.197 in
[Specular reflective]
20 micro s: 0 to +4.6 mm 0 to +0.181 in
10 micro s: +3.6 to +4.6 mm +0.142 to +0.181 in
0.1 micro m 0.004 mil [256]
0.025 micro m 0.001 mil [4,096]
(Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance.
plus or minus 0.03 % F.S.
(Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
0.01 % F.S./degrees
Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Class 2 (IEC / JIS), Class II (FDA)
Max. output: 1 mW
30 x 1,200 micro m 1.181 x 47.244 mil approx.
(Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity.
If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
Linear image sensor
Green LED (lights up during laser emission)
Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
IP67 (IEC) (excluding the connector)
Incandescent light: 3,000 liter x at the light-receiving face
Cabtyre cable, 0.5 m 1.640 ft long with connector
Extension up to total 30 m 98.425 ft is possible, with optional cable.
0 to +45 degrees +32 to +113 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X,Y and Z directions for two hours each
196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Enclosure: Die-cast aluminum
Case cover: Die-cast aluminum
Front cover: Glass
250 g approx. (including cable)
English warning label: 1 set [The FDA regulations conforming type includes a set of both the IEC label (written in English) and JIS label (written in Japanese)].
Diffuse reflective
Specular reflective
Diffuse reflective: 30 mm 1.181 in
Specular reflective: 26.4 mm 1.039 in
Diffuse reflective: plus or minus 5 mm plus or minus 0.197 in
Specular reflective: plus or minus 4.6 mm plus or minus 0.181 in
(Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows.
[Diffuse reflective]
20 micro s: 0 to +5.0 mm 0 to +0.197 in
10 micro s: +3.8 to +5.0 mm +0.150 to +0.197 in
[Specular reflective]
20 micro s: 0 to +4.6 mm 0 to +0.181 in
10 micro s: +3.6 to +4.6 mm +0.142 to +0.181 in
0.25 micro m 0.010 mil [256]
(Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance.
plus or minus 0.03 % F.S.
(Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
0.01 % F.S./degrees
Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Class 2 (IEC / JIS), Class II (FDA)
Max. output: 1 mW
dia. 30 micro m dia. 1.181 mil approx.
(Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity.
If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
Linear image sensor
Green LED (lights up during laser emission)
Yellow LED
(lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.)
IP67 (IEC) (excluding the connector)
Incandescent light: 3,000 liter x at the light-receiving face
Cabtyre cable, 0.5 m 1.640 ft long with connector
Extension up to total 30 m 98.425 ft is possible, with optional cable.