Part Number List

Results 27
Models table for series Digital Laser Sensor LS-400
Part No.DatasheetCE Marking Directive ComplianceApplicable AmplifiersSensing range:U-LG modeSensing range:STD modeSensing range:FAST modeSensing range:H-SP modeOperation indicatorLaser emission indicatorSpot-shape adjusterProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceVoltage withstandabilityInsulation resistanceVibration resistanceShock resistanceEmitting element:FDA / IEC / JIS standards conforming typeMaterialCableWeight (Typ.)AccessoryEmitting element:IEC / JIS / GB standards conforming type
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
30 to 1,000 mm 1.181 to 39.370 in
30 to 250 mm 1.181 to 9.843 in
30 to 150 mm 1.181 to 5.906 in
30 to 150 mm 1.181 to 5.906 in
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
Multi-turn adjuster
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 1 (FDA / IEC / JIS)
(Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long
(Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 30 g approx
Gross weight: 40 g approx
Explanation label: 1 set
(Labels are written in Japanese and Chinese for compliance with various standards.)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
-
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min.
between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 2 (FDA / IEC / JIS)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 30 g approx
Gross weight: 45 g approx
RF-330(Reflector): 1 pc.
Warning label: 1 set
(Labels are written in Japanese, English and Chinese for compliance with various standards.)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
0.2 to 30 m 0.656 to 98.425 ft
(Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.2 to 20 m 0.656 to 65.617 ft
(Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.2 to 10 m 0.656 to 32.808 ft
(Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.2 to 10 m 0.656 to 32.808 ft
(Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
-
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min.
between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 2 (FDA / IEC / JIS)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 30 g approx
Gross weight: 40 g approx
Warning label: 1 set
(Labels are written in Japanese, English and Chinese for compliance with various standards.)
Red semiconductor laser,
Class 2 (IEC / JIS / GB)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
0.2 to 30 m 0.656 to 98.425 ft
(Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.2 to 20 m 0.656 to 65.617 ft
(Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.2 to 10 m 0.656 to 32.808 ft
(Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.2 to 10 m 0.656 to 32.808 ft
(Note) The sensing range is the value for the RF-230 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.2 m 0.656 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
-
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min.
between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 2 (FDA / IEC / JIS)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 30 g approx
Gross weight: 40 g approx
RF-230(Reflector): 1 pc.
Warning label: 1 set
(Labels are written in Japanese, English and Chinese for compliance with various standards.)
Red semiconductor laser,
Class 2 (IEC / JIS / GB)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
30 to 1,000 mm 1.181 to 39.370 in
30 to 500 mm 1.181 to 19.685 in
30 to 300 mm 1.181 to 11.811 in
30 to 300 mm 1.181 to 11.811 in
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
Multi-turn adjuster
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 2 (FDA / IEC / JIS)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long
(Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 35 g approx
Gross weight: 45 g approx
LS-MR1 Lens attachment for line reflective: 1 pc.
Warning label: 1 set
(Labels are written in Japanese, English and Chinese for compliance)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
-
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min.
between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 2 (FDA / IEC / JIS)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 30 g approx
Gross weight: 45 g approx
RF-330(Reflector): 1 pc.
Warning label: 1 set
(Labels are written in Japanese, English and Chinese for compliance with various standards.)
Red semiconductor laser,
Class 2 (IEC / JIS / GB)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 1 m 0.328 to 3.281 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 1 m 0.328 to 3.281 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
-
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min.
between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 1 (FDA / IEC / JIS)
(Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 30 g approx
Gross weight: 45 g approx
RF-330(Reflector): 1 pc.
Explanation label: 1 set
(Labels are written in Japanese and Chinese for compliance with various standards.)
Red semiconductor laser,
Class 2 (IEC / JIS / GB)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 1 m 0.328 to 3.281 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
0.1 to 1 m 0.328 to 3.281 ft
(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
-
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min.
between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 1 (FDA / IEC / JIS)
(Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long (Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 30 g approx
Gross weight: 45 g approx
Explanation label: 1 set
(Labels are written in Japanese and Chinese for compliance with various standards.)
Red semiconductor laser,
Class 1 (IEC / JIS / GB)
(Max. output: 1 mW Peak emission wavelength: 655 nm 0.026 mil)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
30 to 1,000 mm 1.181 to 39.370 in
30 to 500 mm 1.181 to 19.685 in
30 to 300 mm 1.181 to 11.811 in
30 to 300 mm 1.181 to 11.811 in
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
Multi-turn adjuster
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 2 (FDA / IEC / JIS)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 2 m 6.562 ft long
(Connector for amplifier attached)
(Note) Cable cannot be extended.
Net weight: 30 g approx
Gross weight: 40 g approx
Warning label: 1 set
(Labels are written in Japanese, English and Chinese for compliance with various standards.)
Red semiconductor laser,
Class 2 (IEC / JIS / GB)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
EMC Directive, RoHS Directive
LS-401(P), LS-401(P)-C2, LS-403
30 to 1,000 mm 1.181 to 39.370 in
30 to 500 mm 1.181 to 19.685 in
30 to 300 mm 1.181 to 11.811 in
30 to 300 mm 1.181 to 11.811 in
Orange LED (lights up when the amplifier output is ON)
Green LED (lights up during laser emission)
Multi-turn adjuster
IP40 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in (10 G max.) double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Red semiconductor laser,
Class 2 (FDA / IEC / JIS)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
Enclosure: PBT (Mounting part: PEI)
Lens cover: Acrylic
0.1 mm2, single core two parallel shielded cables, 5 m 16.404 ft long
(Connector for amplifier attached)
(Note) Cable cannot be extended.
Warning label: 1 set
(Labels are written in Japanese, English and Chinese for compliance with various standards.)
Red semiconductor laser,
Class 2 (IEC / JIS / GB)
(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)