Specifications
Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | EMC Directive, RoHS Directive |
Operation Indicator | Orange LED (lights up when sensing output 1 or sensing output 2 is ON) |
Protection | IP40(IEC) |
Ambient Temperature | -10 to +55degrees + 14 to 131 degrees Fahrenheit (If 4 to 7 units are mounted close together, -10 to +50 degrees +14 to +122 degrees Fahrenheit ; if 8 to 12 units are mounted close together, -10 to +45 degrees +14 to +113 degrees Fahrenheit )(No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in (max. 10 G) amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each |
Material | Enclosure: Polycarbonate Cover: Polycarbonate Switch: Polyacetal |
Cable | 0.2mm2 6-core cabtyre cable, 2 m 6.562 ft long |
Weight (Typ.) | Net weight: 75 g approx. Gross weight: 110 g approx. |
Accessory | FX-MB1 (Amplifier protective seal): 1 set |
Supply Voltage | 12 to 24 V DC +10-15% Ripple P-P 10 % or less |
Power Consumption | Normal operation: 1,200 mW or less (Current consumption 50 mA or less at 24 V supply voltage,excluding monitor current output) ECO mode: 980 mW or less (Current consumption 40 mA or less at 24 V supply voltage,excluding monitor current output) |
Sensing Outputs (Sensing Output 1, 2) | NPN open-collector transistor ・Maximum sink current: 50 mA (Note:25 mA if 5 or more amplifier are connected in cascade (excluding cable extension).) ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at max. sink current) (Note:Select either sensing output 2 or external input as the connector type.) |
Sensing Outputs (Sensing Output 1, 2): Output Operation | Selectable either Light-ON or Dark-ON |
Sensing Outputs (Sensing Output 1, 2): Short-Circuit Protection | Incorporated |
Sensing Output Setting: Sensing Output 1 | Normal mode, differential mode, hysteresis mode, window comparator mode, selectable |
Sensing Output Setting: Sensing Output 2 | Normal mode, differential mode, hysteresis mode, self-diagnostic output mode, answer-back output mode, selectable (Note:Select either sensing output 2 or external input.) |
Response Time | H-SP: 60 micro s or less, FAST: 150 micro s or less, STD: 250 micro s or less, LONG: 500 micro s or less, U-LG: 5 ms or less, HYPR: 24 ms or less selectable |
Monitor Current Output | Output current: Approx. 4 to 20 mA (H-SP, FAST, STD: at 0 to 4,000 indication) Response time: 2 ms or less Zero point: 4 mA plus or minus 1 % F.S. Span: 16 mA plus or minus 5 % F.S. Linearity: plus or minus 3 % F.S. Load resistance: 0 to 250 Ohm |
External Input | NPN non-contact input - Signal condition High: +8 V to +V DC or open, Low: 0 to +2 V DC (source current 0.5 mA or less) - Input impedance: 10 kOhm approx.(Note:Select either sensing output 2 or external input.) |
External Input Function | Laser emission halt / teaching (full-auto teaching, limit teaching, 2 point teaching) / logic operation setting / copy lock /display adjustment / data bank load / data bank save, selectable |
Laser Emission Indicator | Green LED (lights up during laser emission) |
Output select Indicator | Yellow LED (lights up when output is selected) |
Digital Display | 8-digit 7-segment digital display (4-digit green LED + 4-digit red LED), MODE indicator (Yellow LED): L/D, CUST, PRO |
Incident Light Indication Range | H-SP/FAST/STD: 0 to 4,000 LONG/U-LG/HYPR: 0 to 9,999 |
Sensitivity Setting | 2-level teaching / limit teaching / full auto teaching / manual adjustment |
Logical Operation | Between sensing output 1 and calculation target: Disabled / and / or / xor, selectable Calculation target: Sensing output 2 / adjacent upstream amplifier (sensing output 1) / external input, selectable |
Timer Function | OFF-delay timer, ON-delay timer, ONE-SHOT timer, ON / OFF-delay timer, ON-delay / ONE-SHOT timer, switchable either effective of ineffective, with variable timer period OFF-delay timer, ON-delay timer, ONE-SHOT timer, switchable either effective of ineffective, with variable timer period |
Timer Function: Time | Timer range '' ms'': 0.5 ms approx., 1 to 9,999 ms approx., in approx. 1 ms intervals Timer range '' sec'': 0.5 sec. approx., 1 to 32 sec. approx., in approx. 1 sec. intervals Timer range '' 1/10 ms'': 0.05 ms approx., 0.1 to 999.9 ms approx., in approx. 0.1 ms intervals, Set separately for each output. |
Automatic Interference Prevention Function | Incorporated (Note:Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR) |
Cable Extension | Extension up to total 100 m 328.084 ft is possible with 0.3mm2, or more, cable. |