Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | EMC Directive, RoHS Directive |
Sensing Range | 300 mm 11.811 in (Note) The sensing range and the hysteresis of the specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. |
Sensing Object | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. |
Hysteresis | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. |
Repeatability (Perpendicular to Sensing Axis) | 0.5 mm 0.020 in or less |
Supply Voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current Consumption | 1 mA or less (Note) It is the leakage current when the output is in the OFF state. |
Sensing Output | Non contact DC 2-wire type - Load current: 5 to 100 mA - Residual voltage: 4 V or less (Note) (Note) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable. |
Sensing Output: Output Operation | Switchable either Light-ON or Dark-ON |
Sensing Output: Short-Circuit Protection | Incorporated |
Response Time | 3 ms or less |
Stability Indicator | Green LED (Light-ON mode: lights up under stable light received condition, Dark-ON mode: lights up under stable dark condition) |
Operation Indicator | Red LED (lights up when the output is ON) |
Emitting Indicator | - |
Sensitivity Adjuster | Continuously variable adjuster |
Protection | IP67 (IEC) |
Ambient Temperature | -20 to +60 degrees -4 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock Resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Material | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate |
Cable | 0.15 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long |
Cable Extension | - (Note) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable. |
Weight (Typ.) | 70 g approx. |
Accessory | MS-RX-1 (Sensor mounting bracket): 1 set Adjusting screwdriver: 1 pc |
Emitting Element | Infrared LED (modulated) |
Emitting Element: Peak Emission Wavelength | 890 nm 0.035 mil |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.