Specification

Specifications table for model RX2-M5-C5
ItemPerformance characteristics
CE Marking Directive ComplianceEMC Directive, RoHS Directive
Sensing Range 5 m 16.404 ft
Sensing Object dia. 10 mm dia. 0.394 in or more opaque object
(Note) If slit masks (optional) are fitted, an object of 0.5 x 5 mm 0.020 x 0.197 in can be detected.
Hysteresis-
Repeatability (Perpendicular to Sensing Axis) 0.5 mm 0.020 in or less
Supply Voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Current ConsumptionEmitter: 8 mA or less
Receiver: 0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Sensing Output Non contact DC 2-wire type
- Load current: 5 to 100 mA
- Residual voltage: 4 V or less (Note)
(Note) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable.
Sensing Output: Output OperationSwitchable either Light-ON or Dark-ON
Sensing Output: Short-Circuit ProtectionIncorporated
Response Time3 ms or less
Stability IndicatorGreen LED (Light-ON mode: lights up under stable light received condition, Dark-ON mode: lights up under stable dark condition)
Operation Indicator Red LED (lights up when the output is ON)
Emitting IndicatorRed LED (lights up during beam emission)
Sensitivity AdjusterContinuously variable adjuster
ProtectionIP67 (IEC)
Ambient Temperature-20 to +60 degrees -4 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient IlluminanceIncandescent light: 3,500 Lx or less at the light-receiving face
Voltage Withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation Resistance20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration Resistance10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
Shock Resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
MaterialEnclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
Cable0.15 mm2 2-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long
Cable Extension-
(Note) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable.
AccessoryMS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver
Adjusting screwdriver: 1 pc
Emitting ElementInfrared LED (modulated)
Emitting Element: Peak Emission Wavelength880 nm 0.035 mil