Light Curtains: Ultra-slim Safety door switch SG-A1

Model List

Found 6 matches. Display 1 - 6 matches.
Part No.sort descendingData SheetDoor monitor contactsCable lengthApplicable standardsApplicable standards : Standards for useApplicable directivesOperating condition : Ambient temperatureOperating condition : Ambient humidityOperating condition : Pollution degreeOperating condition : AltitudeImpulse withstand voltage (Uimp)Parts Inventory
   Column active Filter
Close

Filter by Door monitor contacts

Column active Filter
Close

Filter by Cable length

Column active Filter
Close

Filter by Applicable standards

Column active Filter
Close

Filter by Applicable standards : Standards for use

Column active Filter
Close

Filter by Applicable directives

Column active Filter
Close

Filter by Operating condition : Ambient temperature

Column active Filter
Close

Filter by Operating condition : Ambient humidity

Column active Filter
Close

Filter by Operating condition : Pollution degree

Column active Filter
Close

Filter by Operating condition : Altitude

Column active Filter
Close

Filter by Impulse withstand voltage (Uimp)

 
design engineersPanasonicSG-A1-03-1
3NC1 m 3.281 ftEN 1088, IEC 60947-5-1, EN 60947-5-1,
GS-ET-15, UL 508, CSA C22.2 No.14
IEC 60204-1, EN 60204-1Machinery directive (2006/42/EC)
Low voltage directive (2006/95/EC)
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
45 to 85 % RH3 (Inside 2)2,000 m 6,561.68 ft max.4 kV
design engineersPanasonicSG-A1-03-5
3NC5 m 16.404 ftEN 1088, IEC 60947-5-1, EN 60947-5-1,
GS-ET-15, UL 508, CSA C22.2 No.14
IEC 60204-1, EN 60204-1Machinery directive (2006/42/EC)
Low voltage directive (2006/95/EC)
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
45 to 85 % RH3 (Inside 2)2,000 m 6,561.68 ft max.4 kV
design engineersPanasonicSG-A1-12-1
2NC+1NO1 m 3.281 ftEN 1088, IEC 60947-5-1, EN 60947-5-1,
GS-ET-15, UL 508, CSA C22.2 No.14
IEC 60204-1, EN 60204-1Machinery directive (2006/42/EC)
Low voltage directive (2006/95/EC)
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
45 to 85 % RH3 (Inside 2)2,000 m 6,561.68 ft max.4 kV
design engineersPanasonicSG-A1-12-5
2NC+1NO5 m 16.404 ftEN 1088, IEC 60947-5-1, EN 60947-5-1,
GS-ET-15, UL 508, CSA C22.2 No.14
IEC 60204-1, EN 60204-1Machinery directive (2006/42/EC)
Low voltage directive (2006/95/EC)
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
45 to 85 % RH3 (Inside 2)2,000 m 6,561.68 ft max.4 kV
design engineersPanasonicSG-A1-02-5
2NC5 m 16.404 ftEN 1088, IEC 60947-5-1, EN 60947-5-1,
GS-ET-15, UL 508, CSA C22.2 No.14
IEC 60204-1, EN 60204-1Machinery directive (2006/42/EC)
Low voltage directive (2006/95/EC)
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
45 to 85 % RH3 (Inside 2)2,000 m 6,561.68 ft max.4 kV
design engineersPanasonicSG-A1-02-1
2NC1 m 3.281 ftEN 1088, IEC 60947-5-1, EN 60947-5-1,
GS-ET-15, UL 508, CSA C22.2 No.14
IEC 60204-1, EN 60204-1Machinery directive (2006/42/EC)
Low voltage directive (2006/95/EC)
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
45 to 85 % RH3 (Inside 2)2,000 m 6,561.68 ft max.4 kV