GT704

High-quality 4.6" Monochrome Display with high resolution and improved readability. Offered in eight (8) different models that are all IoT capable due to a built-in ethernet port.

Features: 

  • 3-Color LED Backlight 
  • 640 x 240 Resolution 
  • SD Memory Card Slot 
  • IP67 Rating  

Part Number List

Results 8
Models table for series GT704
Part No.DatasheetCE Marking Directive CompliancePower SupplyOperating Voltage Range Power ConsumptionPower Supply Unit Isolation MethodAmbient TemperatureAmbient HumidityStorage TemperatureStorage Humidity Vibration ResistanceShock ResistanceSuperposed Noise SuppressionEnvironmental ResistanceNet Weight Display: Display DeviceDisplay: ResolutionDisplay: Display ColorDisplay: Displayable AreaDisplay: BacklightFunctions: Font TypesFunctions: LanguagesFunctions: GraphicsFunctions: Number of ScreensFunctions: Screen Setting No.Functions: Part FunctionsFunctions: Other FunctionsFunctions: Clock FunctionFunctions: Backlight Brightness AdjustmentFunctions: Contrast AdjustmentFunctions: BuzzerFunctions: Automatic Communication SettingsFunctions: Through Function Functions: Screen CreationTouch Key ResolutionTouch Key Operation Force Touch Key LifeCOM. Port: Communication StandardCOM. Port: External Communication ConditionsCOM. Port: ProtocolCOM. Port: ConnectorScreen Data Transfer Interface: Communication StandardScreen Data Transfer Interface: ProtocolScreen Data Transfer Interface: ConnectorUser’s Memory: MemoryUser's Memory: CapacityMemory Backup: MemoryMemory Backup: Backup BatteryEthernet port:InterfaceEthernet port:Baud rateEthernet port:ProtocolEthernet port:Connector shapeile No.No.
EMC Directive, RoHS Directive
24 V DC
21.6 to 26.4 V DC
2.4 W or less
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages), Dust-proof and drip-proof from the front of the panel only, (Rubber packing is attached to the panel contact surface.)
(Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
240 g approx.
TFT monochrome LCD
640 (W) × 240 (H) dots
2 colors (black / white, 64-gray scale)
108.8 (W) × 40.8 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height.
True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, German, Italian, Spanish, French, Turkish, Russian, Vietnamese
Straight lines, Continuous straight lines, Squares, Circles, Arcs, Curves, Fan shapes, Polygons, Fill, Bitmaps
250 screens approx.(Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.)
* Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC.
(There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10.
Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Conforms to RS-232C
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation
(Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol
Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508
EMC Directive, RoHS Directive
24 V DC
21.6 to 26.4 V DC
2.4 W or less
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages), Dust-proof and drip-proof from the front of the panel only, (Rubber packing is attached to the panel contact surface.)
(Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
240 g approx.
TFT monochrome LCD
640 (W) × 240 (H) dots
2 colors (black / white, 64-gray scale)
108.8 (W) × 40.8 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height.
True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, German, Italian, Spanish, French, Turkish, Russian, Vietnamese
Straight lines, Continuous straight lines, Squares, Circles, Arcs, Curves, Fan shapes, Polygons, Fill, Bitmaps
250 screens approx.(Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.)
* Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC.
(There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10.
Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Conforms to RS-422/RS-485
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation
(Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol
Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508
EMC Directive, RoHS Directive
24 V DC
21.6 to 26.4 V DC
2.4 W or less
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages), Dust-proof and drip-proof from the front of the panel only, (Rubber packing is attached to the panel contact surface.)
(Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
240 g approx.
TFT monochrome LCD
640 (W) × 240 (H) dots
2 colors (black / white, 64-gray scale)
108.8 (W) × 40.8 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height.
True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, German, Italian, Spanish, French, Turkish, Russian, Vietnamese
Straight lines, Continuous straight lines, Squares, Circles, Arcs, Curves, Fan shapes, Polygons, Fill, Bitmaps
250 screens approx.(Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.)
* Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC.
(There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10.
Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Conforms to RS-422/RS-485
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation
(Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol
Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508
EMC Directive, RoHS Directive
24 V DC
21.6 to 26.4 V DC
2.4 W or less
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages), Dust-proof and drip-proof from the front of the panel only, (Rubber packing is attached to the panel contact surface.)
(Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
240 g approx.
TFT monochrome LCD
640 (W) × 240 (H) dots
2 colors (black / white, 64-gray scale)
108.8 (W) × 40.8 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height.
True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, German, Italian, Spanish, French, Turkish, Russian, Vietnamese
Straight lines, Continuous straight lines, Squares, Circles, Arcs, Curves, Fan shapes, Polygons, Fill, Bitmaps
250 screens approx.(Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.)
* Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC.
(There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10.
Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Conforms to RS-232C
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation
(Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol
Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508
EMC Directive, RoHS Directive
24 V DC
21.6 to 26.4 V DC
2.4 W or less
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages), Dust-proof and drip-proof from the front of the panel only, (Rubber packing is attached to the panel contact surface.)
(Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
240 g approx.
TFT monochrome LCD
640 (W) × 240 (H) dots
2 colors (black / white, 64-gray scale)
108.8 (W) × 40.8 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height.
True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, German, Italian, Spanish, French, Turkish, Russian, Vietnamese
Straight lines, Continuous straight lines, Squares, Circles, Arcs, Curves, Fan shapes, Polygons, Fill, Bitmaps
250 screens approx.(Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.)
* Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC.
(There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10.
Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Conforms to RS-422/RS-485
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation
(Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol
Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508
EMC Directive, RoHS Directive
24 V DC
21.6 to 26.4 V DC
2.4 W or less
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages), Dust-proof and drip-proof from the front of the panel only, (Rubber packing is attached to the panel contact surface.)
(Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
240 g approx.
TFT monochrome LCD
640 (W) × 240 (H) dots
2 colors (black / white, 64-gray scale)
108.8 (W) × 40.8 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height.
True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, German, Italian, Spanish, French, Turkish, Russian, Vietnamese
Straight lines, Continuous straight lines, Squares, Circles, Arcs, Curves, Fan shapes, Polygons, Fill, Bitmaps
250 screens approx.(Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.)
* Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC.
(There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10.
Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Conforms to RS-422/RS-485
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation
(Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol
Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508
EMC Directive, RoHS Directive
24 V DC
21.6 to 26.4 V DC
2.4 W or less
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages), Dust-proof and drip-proof from the front of the panel only, (Rubber packing is attached to the panel contact surface.)
(Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
240 g approx.
TFT monochrome LCD
640 (W) × 240 (H) dots
2 colors (black / white, 64-gray scale)
108.8 (W) × 40.8 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (white / pink / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height.
True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, German, Italian, Spanish, French, Turkish, Russian, Vietnamese
Straight lines, Continuous straight lines, Squares, Circles, Arcs, Curves, Fan shapes, Polygons, Fill, Bitmaps
250 screens approx.(Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.)
* Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC.
(There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10.
Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Conforms to RS-232C
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation
(Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol
Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508
EMC Directive, RoHS Directive
24 V DC
21.6 to 26.4 V DC
2.4 W or less
Transformer isolation
0 to +50 ℃ +32 to +122 ℉
20 to 85 % RH (at +25 ℃ +77 ℉) (No dew condensation allowed)
-20 to +60 ℃ -4 to +140 ℉
10 to 85% RH (at 25 ℃ +77 ℉) (No dew condensation allowed)
5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
147 m/s2, 3 times in each of the X, Y and Z directions
1,000 V [P-P] or more, pulse width of 50 ns, 1 μs between power supply terminals (by a noise simulator)
IP67 (in the initial stages), Dust-proof and drip-proof from the front of the panel only, (Rubber packing is attached to the panel contact surface.)
(Note):This protective structure condition applies to the front surface of the installed panel. This condition does not guarantee usage in all environments provided by users. When reattaching the panel, replace the waterproof packing.
240 g approx.
TFT monochrome LCD
640 (W) × 240 (H) dots
2 colors (black / white, 64-gray scale)
108.8 (W) × 40.8 (H) mm 3.484 (W) × 1.394 (H) in
3-color LED (green / orange / red)
Fixed (GTWIN) : 8 × 8, 16 × 8, and 16 × 16 dots, Characters can be displayed in the 1, 2, 4, 8 or 16 times width or height.
True Type (GTWIN): 10 to 192 dots, Windows®: 10 to 240 dots
Japanese, English, Simplified Chinese, Traditional Chinese, Korean, German, Italian, Spanish, French, Turkish, Russian, Vietnamese
Straight lines, Continuous straight lines, Squares, Circles, Arcs, Curves, Fan shapes, Polygons, Fill, Bitmaps
250 screens approx.(Note):The number of screens that can be registered varies according to the registered contents.
Base screens: No. 0 to 3FF, Key board screens: No. 0 to 7, Login screens: No. 0 to F
Lamps, Switches, Data, Bar graphs, Clocks, Keyboards, Line graphs, Alarm list, Alarm history
Recipe, Flow display, Write device, Multi language exchange, Multiple PLC connection, Operation security, GT link, Data logging, SD recipe (Note):The data logging and SD recipe functions are available with only models equipped with an SD / SDHC memory card slot.
Provided with a built-in clock. (Can also refer to and display a PLC clock.)
* Buy the backup battery [AFPX-BATT].
Can be set on the menu screen, via the GT configuration screen of GTWIN, or via PLC.
(There are some minor variations in the backlight brightness.)
Unnecessary
Installed
The communication speed (baud rate) is automatically changed if there is no response from the target equipment.
GT connected between PC and PLC allows PLC to be debugged without a direct connection to a PC.
Dedicated software should be used. Applicable OS: Windows® Vista / 7 / 8 / 8.1 / 10 (Note):The 64-bit version is not supported except for Windows® 7 / 8 / 8.1 / 10.
Windows is registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Free layout (8 dots min.)
0.8 N or less
1 million operations or more (at +25 ℃ +77 ℉)
Conforms to RS-232C
Baud rate: 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps
Data bits: 7 or 8 bits, Parity: None, Odd, Even, Stop bits: 1 bit
Our FP series supported, General-purpose serial interface supported, Modbus RTU mode protocol
(Master / Slave) supported and Other companies' PLC supported
(Refer to the compatible PLC list for manufacturers and models.)
Connector terminal block (8 pins)
USB2.0
Our dedicated protocol
USB Mini-B
F-ROM
16Mbyte
SRAM
-
100BASE-TX / 10BASE-T
100Mbps/10Mbps automatic negotiation
(Note) : Switching between different speeds is done automatically by auto negotiation function.
Our dedicated protocol
Our FP series supported, Modbus-TCP supported and Other companies' PLC supported (Mitsubishi Electric MC protocol)
Plug-in phone jack (RJ-45)
E96300
UL508