Specification

Specifications table for model ER-X064
ItemPerformance characteristics
CE Marking Compliant DirectivesEMC Directive, RoHS Directive
Effective Charge Removal Width640 mm 25.197 in approx.
Charge Removal Time1 second or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
Ion Balanceplus or minus 30 V or less
(Note: In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply.)
(Note: Ion balance is average of plus and minus. Also, the specification value is typical value in condition of less than plus or minus 10 degrees ambient temperature change, set the ion balance after 30 minutes of the discharge starting, switching on the ion balance control function.)
Discharge MethodPulse AC method
Discharge Frequency100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz
(Note: The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.)
Discharge Output Voltage±7,000 V approx.
Maximum Air Pressure 0.5 Mpa
Ozone Generation0.01 ppm or less
Applicable FluidAir (dried clean air)
(Note:The dried clean air is dried (dew point: equivalent of -20 ℃) and filtered (mesh-size: equivalent of 0.01 micro m) air.)
Operating Altitude2,000 m 6561.68 ft or less
(Note:Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.)
Ambient Temperature0 to +50 °C +32 to +122 °F (No dew condensation), Storage: -10 to +65 °C +14 to +149 °F
Ambient Humidity35 to 65 % RH, Storage: 35 to 85 % RH
Vibration Resistance10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock Resistance100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each
Enclosure EarthingFloating
MaterialMain unit enclosure: PPS, Stainless steal (SUS)
Head mounting bracket: Stainless steal (SUS), Discharge needle: Tungsten
Weight (Typ.)Net weight : 780 g approx.
Length of High-Voltage Cable0.5 m 1.640 ft
(Note:The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office.)

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.