Part Number List

Results 10
Models table for series DQ Relays
Part No.DatasheetOperating Function Rated Coil VoltageContact CapacityProtective ConstructionTerminal TypePacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Set Voltage Reset VoltageRated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage (at 20°C 68°F)Contact ArrangementContact ShapeContact SpecificationContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilTime (Initial) (at 20°C 68°F) (Initial) Reset Time (Initial) (at20°C 68°F) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive Load
1 coil latching
6V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
83.3 mA
72 Ω
500mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
1 coil latching
12V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
41.7 mA
288 Ω
500mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
2 coil latching
9V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
Set coil: 111.1 mA
Reset coil: 111.1 mA
Set coil: 81 Ω
Reset coil: 81 Ω
1000mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
1 coil latching
4.5V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
111.1 mA
40.5 Ω
500mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
2 coil latching
4.5V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
Set coil: 221.7 mA
Reset coil: 221.7 mA
Set coil: 20.3 Ω
Reset coil: 20.3 Ω
1000mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
2 coil latching
12V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
Set coil: 83.3 mA
Reset coil: 83.3 mA
Set coil: 144 Ω
Reset coil: 144 Ω
1000mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
2 coil latching
6V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
Set coil: 166.7 mA
Reset coil: 166.7 mA
Set coil: 36 Ω
Reset coil: 36 Ω
1000mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
1 coil latching
24V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
20.8 mA
1,152 Ω
500mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
1 coil latching
9V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
55.6 mA
162 Ω
500mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)
2 coil latching
24V DC
30A
Sealed
Tab terminal
20
200
70%V or less of rated coil voltage (Initial)
70%V or less of rated coil voltage (Initial)
Set coil: 41.7 mA
Reset coil: 41.7 mA
Set coil: 576 Ω
Reset coil: 576 Ω
1000mW
130%V of rated coil voltage (Initial)
1 Form A
Single
Standard contact
Max. 30mΩ (by voltage drop 6V DC 1A)
AgSnO2 type
30A 250V AC
7,500 VA
250V AC
30A (AC)
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength
AC 1,500 Vrms for 1 min. (detection current: 10 mA)
AC 4,000 Vrms for 1 min. (detection current: 10 mA)
10,000 V
Max. 20 ms (at rated coil voltage, without bounce)
Max. 20 ms (at rated coil voltage, without bounce)
Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs)
Min. 1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 1x106 (at 180 times/min.)
Ambient temperature: –40 to +65°C –40 to +149°F,
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Approx. 35 g 1.23 oz
Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s)