Part No. | Datasheet | Operating Function | Rated Coil Voltage | Contact Capacity | Protective Construction | Terminal Type | Packing Quantity; Inner Carton (Pcs.) | Packing Quantity; Outer Carton (Pcs.) | Set Voltage | Reset Voltage | Rated Operating Current [±10%] (at 20°C) | Resistance [±10%] (at 20°C) | Rated Operating Power | Max. Allowable Voltage (at 20°C 68°F) | Contact Arrangement | Contact Shape | Contact Specification | Contact Resistance (Initial) | Contact Material | Contact Rating (Resistive Load) | Max. Switching Power (Resistive Load) | Max. Switching Voltage | Max. Switching Current | Min. Switching Load (Reference Value) | Insulation Resistance (Initial) | Dielectric Strength (Initial): Between Open Contacts | Dielectric Strength (Initial): Between Contact and Coil | Surge Withstand Voltage (Initial): Between Contact and Coil | Time (Initial) (at 20°C 68°F) (Initial) | Reset Time (Initial) (at20°C 68°F) | Hock Resistance (Functional) | Hock Resistance (Destructive) | Vibration Resistance (Functional) | Vibration Resistance (Destructive) | Mechanical Life | Conditions | Weight (Typ.) | Resistive Load |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 coil latching | 6V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | 83.3 mA | 72 Ω | 500mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
1 coil latching | 12V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | 41.7 mA | 288 Ω | 500mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
2 coil latching | 9V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | Set coil: 111.1 mA Reset coil: 111.1 mA | Set coil: 81 Ω Reset coil: 81 Ω | 1000mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
1 coil latching | 4.5V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | 111.1 mA | 40.5 Ω | 500mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
2 coil latching | 4.5V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | Set coil: 221.7 mA Reset coil: 221.7 mA | Set coil: 20.3 Ω Reset coil: 20.3 Ω | 1000mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
2 coil latching | 12V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | Set coil: 83.3 mA Reset coil: 83.3 mA | Set coil: 144 Ω Reset coil: 144 Ω | 1000mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
2 coil latching | 6V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | Set coil: 166.7 mA Reset coil: 166.7 mA | Set coil: 36 Ω Reset coil: 36 Ω | 1000mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
1 coil latching | 24V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | 20.8 mA | 1,152 Ω | 500mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
1 coil latching | 9V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | 55.6 mA | 162 Ω | 500mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) | ||
2 coil latching | 24V DC | 30A | Sealed | Tab terminal | 20 | 200 | 70%V or less of rated coil voltage (Initial) | 70%V or less of rated coil voltage (Initial) | Set coil: 41.7 mA Reset coil: 41.7 mA | Set coil: 576 Ω Reset coil: 576 Ω | 1000mW | 130%V of rated coil voltage (Initial) | 1 Form A | Single | Standard contact | Max. 30mΩ (by voltage drop 6V DC 1A) | AgSnO2 type | 30A 250V AC | 7,500 VA | 250V AC | 30A (AC) | 100mA 5V DC | Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric strength | AC 1,500 Vrms for 1 min. (detection current: 10 mA) | AC 4,000 Vrms for 1 min. (detection current: 10 mA) | 10,000 V | Max. 20 ms (at rated coil voltage, without bounce) | Max. 20 ms (at rated coil voltage, without bounce) | Min. 200 m/s2 (half-sine shock pulse: 11 ms; detection time: 10 µs) | Min. 1,000 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10µs) | 10 to 55 Hz at double amplitude of 2.0 mm | Min. 1x106 (at 180 times/min.) | Ambient temperature: –40 to +65°C –40 to +149°F, Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) | Approx. 35 g 1.23 oz | Min. 1x104 ope. 30A 250V AC (ON:OFF = 3 s:3 s) |