Specification

Specifications table for model JS1a-B-6V-FT
ItemPerformance characteristics
Protective ConstructionSealed
Coil Insulation ClassClass B insulation
Flame/Tracking ResistanceEN60335-1 (Conform)
Rated Coil Voltage6 V DC
Contact Arrangement1 Form A
Operating Function Single side stable
Terminal TypePC board terminal
Packing Quantity; Outer Carton (Pcs.)500
Packing Quantity; Inner Carton (Pcs.) 100
Operate Voltage (@20oC)Max. 70% V of Rated coil voltage (initial)
Release Voltage (at20°C) Min. 10% V of Rated coil voltage (initial)
Rated Operating Current [±10%] (at 20°C)60 mA
Resistance [±10%] (at 20°C) 100 Ω
Rated Operating Power 360 mW
Max. Allowable Voltage 130% V of Rated coil voltage (at 85°C)
Contact ShapeSingle
Contact Resistance (Initial)Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
Max. Switching Power (Resistive Load) 2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
Max. Switching Voltage277 V AC, 100 V DC (0.5A)
Max. Switching Current10 A (AC), 5 A (DC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts750 Vrms for 1 min. (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil1,500 Vrms for 1 min. (detection current: 10 mA)
Release Time (Initial) (at 20°C) Max. 10 ms (at rated coil voltage, without bounce, without diode)
Operate Time (Initial) (At 20oC)Max. 10 ms (at rated coil voltage, without bounce)
Hock Resistance (Functional)Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Hock Resistance (Destructive)Min. 980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 2.0 mm)
Mechanical LifeMin. 1x107 ope. (at 180 times/min.)
ConditionsAmbient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Weight (Typ.)Approx. 12 g
Resistive LoadMin. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.