Specification

Specifications table for model SP2-DC24V
ItemPerformance characteristics
Operating Function Single side stable
Terminal TypePlug-in terminal
Rated Coil Voltage24 V DC
Contact Arrangement2 Form C
Protective ConstructionDust Cover
AccessoriesTerminal and mounting board are available.
Packing Quantity; Inner Carton (Pcs.) 20
Packing Quantity; Outer Carton (Pcs.)200
Operate Voltage (@20oC)Max. 70% V of rated coil voltage (Initial)
Release Voltage (at20°C) Min. 10% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)12.5 mA
Resistance [±10%] (at 20°C) 1,920 Ω
Rated Operating Power 300 mW
Max. Allowable Voltage (at 20°C 68°F)150% V of rated coil voltage
Contact ShapeTwin
Contact Resistance (Initial)Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialStationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
Contact Rating (Resistive Load)15 A 250 V AC, 10 A 30 V DC
Max. Switching Power (Resistive Load) 3,750 VA, 300 W
Max. Switching Voltage250 V AC, 30 V DC (48 V DC: Max. 2 A)
Max. Switching Current15 A (AC), 10 A (DC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,500 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact Sets3,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil3,000 Vrms for 1 min (detection current: 10 mA)
Operate Time (Initial) (At 20oC)Max. 50 ms at rated coil voltage (without bounce)
Release Time (Initial) (at 20°C) Max. 20 ms at rated coil voltage (without bounce, without diode)
Hock Resistance (Functional)392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 µs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 3 mm)
Mechanical LifeMin. 50x106 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -50 to +60°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 50 g
Resistive Load[switching frequency: at 20 times/min]
Min. 100x103 ope. 15 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.