Item | Performance characteristics |
---|---|
Operating Function | 2 coil latching |
Terminal Type | Plug-in terminal |
Rated Coil Voltage | 24 V DC |
Contact Arrangement | 2 Form C |
Protective Construction | Dust Cover |
Accessories | Terminal and mounting board are available. |
Packing Quantity; Inner Carton (Pcs.) | 20 |
Packing Quantity; Outer Carton (Pcs.) | 200 |
Rated Operating Current [±10%] (at 20°C) | Set coil: 12.5 mA Reset coil: 12.5 mA |
Resistance [±10%] (at 20°C) | Set coil: 1,920 Ω Reset coil: 1,920 Ω |
Rated Operating Power | 300 mW |
Max. Allowable Voltage (at 20°C 68°F) | 150% V of rated coil voltage |
Contact Shape | Twin |
Contact Resistance (Initial) | Max. 30 mΩ (by voltage drop 6 V DC 1 A) |
Contact Material | Stationary contact: Au flashed AgSnO2 type Movable contact: AgSnO2 type |
Contact Rating (Resistive Load) | 15 A 250 V AC, 10 A 30 V DC |
Max. Switching Power (Resistive Load) | 3,750 VA, 300 W |
Max. Switching Voltage | 250 V AC, 30 V DC (48 V DC: Max. 2 A) |
Max. Switching Current | 15 A (AC), 10 A (DC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,500 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact Sets | 3,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 3,000 Vrms for 1 min (detection current: 10 mA) |
Hock Resistance (Functional) | 392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 3 mm) |
Mechanical Life | Min. 50x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -50 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Weight (Typ.) | Approx. 50 g |
Resistive Load | [switching frequency: at 20 times/min] Min. 100x103 ope. 15 A 250 V AC Min. 100x103 ope. 10 A 30 V DC |
Set Voltage | Max. 70% V of rated coil voltage (Initial) |
Reset Voltage | Max. 70% V of rated coil voltage (Initial) |
Time (Initial) (at 20°C 68°F) (Initial) | Max. 50 ms at rated coil voltage (without bounce) |
Reset Time (Initial) (at20°C 68°F) | Max. 50 ms at rated coil voltage (without bounce, without diode) |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.
New Product Introduction: DS-P Series