DW Series Relays

Panasonic's DW Series Polarized Power Relays feature up to 16A @ 277 VAC switching capacity in the same compact size. In addition to the DW Series lineup is the high inrush type that offers up to a 100A inrush capability with a 600W nominal operating power. The DW Series is available in 1 and 2 coil latching configurations.
 
Features:

  • Latching Relay- Ideal for Energy Saving Devices
  • IEC60335-1 Compliant, PTI325V (VDE Approved) Type Available
  • Surge Breakdown Voltage (Between Contact and Coil): 12,000 V
  • Breakdown Voltage (Between Contact and Coil): 5,000 V
  • Pin-In-Paste Construction Makes Reflow Possible

Benefits:

  • Can Run at High Operating Power
  • Robust Under Stressful Operating Conditions
  • High Reliability

Part Number List

Results 48
Models table for series DW Series Relays
Part No.DatasheetOperating Function Contact TypeType ClassificationRated Coil VoltageProtective ConstructionTerminal TypePacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Set Voltage Reset VoltageRated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage (at 20°C 68°F)Contact ArrangementContact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilSurge Withstand Voltage (Initial): Between Contact and CoilTime (Initial) (at 20°C 68°F) (Initial) Reset Time (Initial) (at20°C 68°F) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive LoadInrush Load; TungstenPacking Quantity
1 coil latching
Inrush type (16A, Inrush current 100A)
Low profile type
6 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
33.3 mA
180 Ω
200 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70°C (Over 8A to 16A)
Ambient temperature: -40 to +85°C (8A or less)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7.5 g
Min. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min)
Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s)
Min. 25x103 ope.
Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s)
Carton
1 coil latching
Inrush type (16A, Inrush current 100A)
IEC60335-1compliant type
5 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
40 mA
125 Ω
200 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70°C (Over 8A to 16A)
Ambient temperature: -40 to +85°C (8A or less)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
Min. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min)
Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s)
Min. 25x103 ope.
Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s)
Carton
1 coil latching
Inrush type (16A, Inrush current 100A)
IEC60335-1compliant type
6 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
33.3 mA
180 Ω
200 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70°C (Over 8A to 16A)
Ambient temperature: -40 to +85°C (8A or less)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
Min. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min)
Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s)
Min. 25x103 ope.
Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s)
Carton
1 coil latching
Standard type (8A)
IEC60335-1compliant type
6 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
33.3 mA
180 Ω
200 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
8 A 250 V AC
2,000 VA
250 V AC
8 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
[switching frequency: 20 times/min]
Min. 50x103 ope. 8 A 250 V AC
Min. 100x103 ope. 5 A 250 V AC
Carton
1 coil latching
Standard type (8A)
Reflow compatible type
3 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
66.7 mA
45 Ω
200 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
8 A 250 V AC
2,000 VA
250 V AC
8 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
[switching frequency: 20 times/min]
Min. 50x103 ope. 8 A 250 V AC
Carton
2 coil latching
Inrush type (16A, Inrush current 100A)
IEC60335-1compliant type
9 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
Set coil: 44.4 mA
Reset coil: 44.4 mA
Set coil: 202.5 Ω
Reset coil: 202.5 Ω
400 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70°C (Over 8A to 16A)
Ambient temperature: -40 to +85°C (8A or less)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
Min. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min)
Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s)
Min. 25x103 ope.
Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s)
Carton
2 coil latching
Standard type (8A)
IEC60335-1compliant type
9 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
Set coil: 44.4 mA
Reset coil: 44.4 mA
Set coil: 202.5 Ω
Reset coil: 202.5 Ω
400 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
8 A 250 V AC
2,000 VA
250 V AC
8 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
[switching frequency: 20 times/min]
Min. 50x103 ope. 8 A 250 V AC
Min. 100x103 ope. 5 A 250 V AC
Carton
2 coil latching
Inrush type (16A, Inrush current 100A)
Low profile type
12 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
Set coil: 33.3 mA
Reset coil: 33.3 mA
Set coil: 360 Ω
Reset coil: 360 Ω
400 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70°C (Over 8A to 16A)
Ambient temperature: -40 to +85°C (8A or less)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 7.5 g
Min. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min)
Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s)
Min. 25x103 ope.
Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s)
Carton
2 coil latching
Inrush type (16A, Inrush current 100A)
IEC60335-1compliant type
5 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
Set coil: 80 mA
Reset coil: 80 mA
Set coil: 62.5 Ω
Reset coil: 62.5 Ω
400 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
16 A 277 V AC
4,432 VA
277 V AC
16 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +70°C (Over 8A to 16A)
Ambient temperature: -40 to +85°C (8A or less)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
Min. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min)
Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s)
Min. 25x103 ope.
Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s)
Carton
2 coil latching
Standard type (8A)
IEC60335-1compliant type
5 V DC
Flux-resistant
PC board terminal
100
500
Max. 80% V of rated coil voltage (Initial)
Max. 80% V of rated coil voltage (Initial)
Set coil: 80 mA
Reset coil: 80 mA
Set coil: 62.5 Ω
Reset coil: 62.5 Ω
400 mW
110% V of rated coil voltage
1 Form A
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
8 A 250 V AC
2,000 VA
250 V AC
8 A (AC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,000 Vrms for 1 min (detection current: 10 mA)
5,000 Vrms for 1 min (detection current: 10 mA)
12,000 V
Max. 15 ms at rated coil voltage (without bounce)
Max. 15 ms at rated coil voltage (without bounce)
100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
1,000 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 8 g
[switching frequency: 20 times/min]
Min. 50x103 ope. 8 A 250 V AC
Min. 100x103 ope. 5 A 250 V AC
Carton