| | Plug-in terminal | DC type (DC coil) | 6 V DC | 1,920 mW | 1 Form A | Dust Cover | Single side stable | Terminals are available. | 20 | 100 | Max. 70% V of rated coil voltage (Initial) | Min. 10% V of rated coil voltage (Initial) | 320 mA | 18.8 Ω | 110% V of rated coil voltage (at 55°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 30 A 277 V AC | 8,310 VA | 277 V AC, 30 V DC | 30 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 10x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 90 g | [switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC | | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Plug-in terminal | AC type (AC coil) | 100/120 V AC | 1.9 VA to 2.7 VA | 2 Form A | Dust Cover | Single side stable | Terminals are available. | 20 | 100 | Max. 70 V AC (Initial) | Min. 18 V AC (Initial) | 18.7 to 22.1 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 90 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Plug-in terminal | AC type (AC coil) | 24 V AC | 1.8 VA | 2 Form A | Dust Cover | Single side stable | Terminals are available. | 20 | 100 | Max. 70% V of rated coil voltage (Initial) | Min. 15% V of rated coil voltage (Initial) | 74 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 90 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Plug-in terminal | AC type (AC coil) | 12 V AC | 1.7 VA | 2 Form A | Dust Cover | Single side stable | Terminals are available. | 20 | 100 | Max. 70% V of rated coil voltage (Initial) | Min. 15% V of rated coil voltage (Initial) | 138 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 90 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Plug-in terminal | AC type (AC coil) | 200/240 V AC | 1.8 VA to 2.6 VA | 2 Form A | Dust Cover | Single side stable | Terminals are available. | 20 | 100 | Max. 140 V AC (Initial) | Min. 36 V AC (Initial) | 9.1 to 10.8 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 90 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Plug-in terminal | AC type (AC coil) | 48 V AC | 1.9 VA | 2 Form A | Dust Cover | Single side stable | Terminals are available. | 20 | 100 | Max. 70% V of rated coil voltage (Initial) | Min. 15% V of rated coil voltage (Initial) | 39 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 90 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Screw terminal | AC type (AC coil) | 24 V AC | 1.8 VA | 2 Form A | Dust Cover | Single side stable | | 10 | 50 | Max. 70% V of rated coil voltage (Initial) | Min. 15% V of rated coil voltage (Initial) | 74 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 120 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Screw terminal | AC type (AC coil) | 48 V AC | 1.9 VA | 2 Form A | Dust Cover | Single side stable | | 10 | 50 | Max. 70% V of rated coil voltage (Initial) | Min. 15% V of rated coil voltage (Initial) | 39 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 120 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Tab terminal (TM type) | AC type (AC coil) | 24 V AC | 1.8 VA | 2 Form A | Dust Cover | Single side stable | | 20 | 100 | Max. 70% V of rated coil voltage (Initial) | Min. 15% V of rated coil voltage (Initial) | 74 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 90 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |
| | Tab terminal (TM type) | AC type (AC coil) | 48 V AC | 1.9 VA | 2 Form A | Dust Cover | Single side stable | | 20 | 100 | Max. 70% V of rated coil voltage (Initial) | Min. 15% V of rated coil voltage (Initial) | 39 mA | | 110% V of rated coil voltage (at 20°C) | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 25 A 277 V AC | 6,925 VA | 277 V AC, 30 V DC | 25 A (AC) | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 2,000 Vrms for 1 min (detection current: 10 mA) | 5,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | Max. 30 ms at rated coil voltage (without bounce) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 980 m/s2 (half-sine shock pulse: 6 ms) | Min. 5x106 ope. (switching frequency: at 180 times/min) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 90 g | [switching frequency: 20 times/min] Min. 200x103 ope. 20 A 250 V AC Min. 100x103 ope. 25 A 277 V AC | 4,000 Vrms for 1 min (detection current: 10 mA) | Carton | Min. 8 mm | Min. 3 mm (reference value) |