Part Number List

Results 83
Models table for series JS Series Relays
Part No.DatasheetProtective ConstructionCoil Insulation ClassFlame/Tracking ResistanceRated Coil VoltageContact ArrangementOperating Function Terminal TypePacking Quantity; Outer Carton (Pcs.)Packing Quantity; Inner Carton (Pcs.) Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage Contact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilRelease Time (Initial) (at 20°C) Operate Time (Initial) (At 20oC)Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive Load
Flux-resistant
Class B insulation
EN60335-1 (Conform)
12 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
30 mA
400 Ω
360 mW
130% V of Rated coil voltage (at 85°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class F insulation
EN60335-1 (Conform)
12 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
30 mA
400 Ω
360 mW
130% V of Rated coil voltage (at 85°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +105°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class E insulation
Not available
12 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
30 mA
400 Ω
360 mW
130% V of Rated coil voltage (at 70°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class B insulation
EN60335-1 (Conform)
24 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
15 mA
1,600 Ω
360 mW
130% V of Rated coil voltage (at 85°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class F insulation
EN60335-1 (Conform)
24 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
15 mA
1,600 Ω
360 mW
130% V of Rated coil voltage (at 85°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +105°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class B insulation
EN60335-1 (Conform)
48 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
7.5 mA
6,400 Ω
360 mW
130% V of Rated coil voltage (at 85°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class F insulation
EN60335-1 (Conform)
48 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
7.5 mA
6,400 Ω
360 mW
130% V of Rated coil voltage (at 85°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +105°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class E insulation
Not available
9 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
40 mA
225 Ω
360 mW
130% V of Rated coil voltage (at 70°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class E insulation
Not available
18 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
20 mA
900 Ω
360 mW
130% V of Rated coil voltage (at 70°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)
Flux-resistant
Class F insulation
EN60335-1 (Conform)
5 V DC
1 Form C
Single side stable
PC board terminal
500
100
Max. 70% V of Rated coil voltage (initial)
Min. 10% V of Rated coil voltage (initial)
72 mA
69.4 Ω
360 mW
130% V of Rated coil voltage (at 85°C)
Single
Max. 100 mΩ (by voltage drop 6 V DC 1 A)
AgSnO2 type
10 A 250 V AC (N.O.), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
2,500 VA 150 W (N.O.), 1,662 VA 150 W (N.C.)
277 V AC, 100 V DC (0.5A)
10 A (AC), 5 A (DC)
100 mA 5 V DC
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
750 Vrms for 1 min. (detection current: 10 mA)
1,500 Vrms for 1 min. (detection current: 10 mA)
Max. 10 ms (at rated coil voltage, without bounce, without diode)
Max. 10 ms (at rated coil voltage, without bounce)
Min. 98 m/s2 (half-sine shock pulse: 11 ms;, detection time: 10 µs)
Min. 980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 2.0 mm)
Min. 1x107 ope. (at 180 times/min.)
Ambient temperature: -40 to +105°C
Humidity: 5 to 85% R.H. (Avoid icing and condensation)
Approx. 12 g
Min. 100,000 ope. 10 A 125 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 6 A 277 V AC (at 20°C, at 20 times/min.)
Min. 100,000 ope. 5 A 30 V DC (at 20°C, at 20 times/min.)
Min. 50,000 ope. 10 A 250 V AC (at 20°C, at 20 times/min.)

What's New

Stay up to date