| | 6V DC | 2 Form A | AgNi type | 20 A 800 V DC, 25A 600V DC (at each 1 Form A contact connected in series), 20 A 400 VDC (at 1 Form A contact only) | 1,000V DC | 25A | 100mA 5V DC | 1,920mW | Max. 70% V of rated coil voltage (initial) (at 20°C) | Min. 5% V of rated coil voltage (initial) (at 20°C) | Min. 106 ope. (switching frequency: at 180 times/min) | Conditions: at 20°C, switching frequency ON : OFF = 1 s : 9 s [Contact connected in series, Resistive load] 20 A 600 V DC Min. 10x103 ope. 20 A 800 V DC Min. 103 ope. 25 A 600 V DC Min. 6x103 ope. [1 Form A contact only, Resistive load] 20 A 300 V DC Min. 10x103 ope. 20 A 400 V DC Min. 103 ope. | 2000Vrms | 5000Vrms | Ambient temperature: -40 to +55°C (When coil holding voltage is 33% to 110% of rated coil voltage) Ambient temperature: -40 to +85°C (When coil holding voltage is 33% to 60% of rated coil voltage) Humidity: 5 to 85% RH (Avoid icing and condensation) | Flux-resistant | Single Side Stable Type | PC board through hole terminal |
| | 15V DC | 2 Form A | AgNi type | 20 A 800 V DC, 25A 600V DC (at each 1 Form A contact connected in series), 20 A 400 VDC (at 1 Form A contact only) | 1,000V DC | 25A | 100mA 5V DC | 1,920mW | Max. 70% V of rated coil voltage (initial) (at 20°C) | Min. 5% V of rated coil voltage (initial) (at 20°C) | Min. 106 ope. (switching frequency: at 180 times/min) | Conditions: at 20°C, switching frequency ON : OFF = 1 s : 9 s [Contact connected in series, Resistive load] 20 A 600 V DC Min. 10x103 ope. 20 A 800 V DC Min. 103 ope. 25 A 600 V DC Min. 6x103 ope. [1 Form A contact only, Resistive load] 20 A 300 V DC Min. 10x103 ope. 20 A 400 V DC Min. 103 ope. | 2000Vrms | 5000Vrms | Ambient temperature: -40 to +55°C (When coil holding voltage is 33% to 110% of rated coil voltage) Ambient temperature: -40 to +85°C (When coil holding voltage is 33% to 60% of rated coil voltage) Humidity: 5 to 85% RH (Avoid icing and condensation) | Flux-resistant | Single Side Stable Type | PC board through hole terminal |
| | 9V DC | 2 Form A | AgNi type | 20 A 800 V DC, 25A 600V DC (at each 1 Form A contact connected in series), 20 A 400 VDC (at 1 Form A contact only) | 1,000V DC | 25A | 100mA 5V DC | 1,920mW | Max. 70% V of rated coil voltage (initial) (at 20°C) | Min. 5% V of rated coil voltage (initial) (at 20°C) | Min. 106 ope. (switching frequency: at 180 times/min) | Conditions: at 20°C, switching frequency ON : OFF = 1 s : 9 s [Contact connected in series, Resistive load] 20 A 600 V DC Min. 10x103 ope. 20 A 800 V DC Min. 103 ope. 25 A 600 V DC Min. 6x103 ope. [1 Form A contact only, Resistive load] 20 A 300 V DC Min. 10x103 ope. 20 A 400 V DC Min. 103 ope. | 2000Vrms | 5000Vrms | Ambient temperature: -40 to +55°C (When coil holding voltage is 33% to 110% of rated coil voltage) Ambient temperature: -40 to +85°C (When coil holding voltage is 33% to 60% of rated coil voltage) Humidity: 5 to 85% RH (Avoid icing and condensation) | Flux-resistant | Single Side Stable Type | PC board through hole terminal |
| | 24V DC | 2 Form A | AgNi type | 20 A 800 V DC, 25A 600V DC (at each 1 Form A contact connected in series), 20 A 400 VDC (at 1 Form A contact only) | 1,000V DC | 25A | 100mA 5V DC | 1,920mW | Max. 70% V of rated coil voltage (initial) (at 20°C) | Min. 5% V of rated coil voltage (initial) (at 20°C) | Min. 106 ope. (switching frequency: at 180 times/min) | Conditions: at 20°C, switching frequency ON : OFF = 1 s : 9 s [Contact connected in series, Resistive load] 20 A 600 V DC Min. 10x103 ope. 20 A 800 V DC Min. 103 ope. 25 A 600 V DC Min. 6x103 ope. [1 Form A contact only, Resistive load] 20 A 300 V DC Min. 10x103 ope. 20 A 400 V DC Min. 103 ope. | 2000Vrms | 5000Vrms | Ambient temperature: -40 to +55°C (When coil holding voltage is 33% to 110% of rated coil voltage) Ambient temperature: -40 to +85°C (When coil holding voltage is 33% to 60% of rated coil voltage) Humidity: 5 to 85% RH (Avoid icing and condensation) | Flux-resistant | Single Side Stable Type | PC board through hole terminal |
| | 12V DC | 2 Form A | AgNi type | 20 A 800 V DC, 25A 600V DC (at each 1 Form A contact connected in series), 20 A 400 VDC (at 1 Form A contact only) | 1,000V DC | 25A | 100mA 5V DC | 1,920mW | Max. 70% V of rated coil voltage (initial) (at 20°C) | Min. 5% V of rated coil voltage (initial) (at 20°C) | Min. 106 ope. (switching frequency: at 180 times/min) | Conditions: at 20°C, switching frequency ON : OFF = 1 s : 9 s [Contact connected in series, Resistive load] 20 A 600 V DC Min. 10x103 ope. 20 A 800 V DC Min. 103 ope. 25 A 600 V DC Min. 6x103 ope. [1 Form A contact only, Resistive load] 20 A 300 V DC Min. 10x103 ope. 20 A 400 V DC Min. 103 ope. | 2000Vrms | 5000Vrms | Ambient temperature: -40 to +55°C (When coil holding voltage is 33% to 110% of rated coil voltage) Ambient temperature: -40 to +85°C (When coil holding voltage is 33% to 60% of rated coil voltage) Humidity: 5 to 85% RH (Avoid icing and condensation) | Flux-resistant | Single Side Stable Type | PC board through hole terminal |