Fiber Sensors: Bank Selection Unit FX-CH

Model List

Found 2 matches. Display 1 - 2 matches.
Part No.sort ascendingData SheetSupply voltageCurrent consumptionBank selection inputPower indicatorTransmission operation indicatorAmbient temperatureAmbient humidityVoltage withstandabilityInsulation resistanceVibration resistanceParts Inventory
   Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Bank selection input

Column active Filter
Close

Filter by Power indicator

Column active Filter
Close

Filter by Transmission operation indicator

Column active Filter
Close

Filter by Ambient temperature

Column active Filter
Close

Filter by Ambient humidity

Column active Filter
Close

Filter by Voltage withstandability

Column active Filter
Close

Filter by Insulation resistance

Column active Filter
Close

Filter by Vibration resistance

 
design engineersPanasonicFX-CH-P
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less25 mA or less (When all indicators light up)High: 4 V to +V DC (Sink current: 0.5 to 3 mA Input impedance: 10 kOhm approx.)
Low: 0 to 0.6 V DC, or open
Green LED (Lights up when the power is ON)Green LED (Lights up when loaded, blinks to lights up when saved)-10 to +55 degrees +14 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit35 to 85 % RH, Storage: 35 to 85 % RH1,000 V AC for one min. between all supply terminals connected together and enclosure20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
design engineersPanasonicFX-CH
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less25 mA or less (When all indicators light up)Low: 0 to 2 V DC (Source current: 0.5 mA Input impedance: 10 kOhm approx.)
High: 5 V to +V DC, or open
Green LED (Lights up when the power is ON)Green LED (Lights up when loaded, blinks to lights up when saved)-10 to +55 degrees +14 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit35 to 85 % RH, Storage: 35 to 85 % RH1,000 V AC for one min. between all supply terminals connected together and enclosure20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each

Related Documents

Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-100 Sensing Characteristics Data sheetFX-100 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-100 Sensing rangeFX-100 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-300 Sensing Characteristics Data sheetFX-300 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-300 Sensing rangeFX-300 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-311 Sensing rangeFX-311 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-410 Sensing rangeFX-410 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-500 Sensing Characteristics Data sheetFX-500 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-500 Sensing rangeFX-500 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Bank Selection Unit FX-CH › FX-CHFX-CH