Fiber Sensors: Communication Unit for Open Network SC-GU3

Model List

Found 10 matches. Display 1 - 10 matches.
Part No.sort ascendingData SheetNumber of connectable unitsAmbient temperatureAmbient humidityMaterialWeightDirective complianceSupply voltageCurrent consumptionAllowable passing currentCommunication methodParts Inventory
   Column active Filter
Close

Filter by Number of connectable units

Column active Filter
Close

Filter by Ambient temperature

Column active Filter
Close

Filter by Ambient humidity

Column active Filter
Close

Filter by Material

Column active Filter
Close

Filter by Weight

Column active Filter
Close

Filter by Directive compliance

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Allowable passing current

Column active Filter
Close

Filter by Communication method

 
design engineersPanasonicSC-GU3-EU
1 unit for 1 communication unit–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RHEnclosure: PolycarbonateNet weight: 20 g approx.
Gross weight: 20 g approx.
n/a11 to 25 V DC Ripple P-P 10 % or less25 mA or lessn/an/a
design engineersPanasonicSC-GU3-03
Maximum of 16 units per SC-GU3-01 unit
(Max. 12 units when FX-500 / LS-500 series are connected)
–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RHEnclosure: PolycarbonateNet weight: 75 g approx.
Gross weight: 120 g approx.
EMC Directive, RoHS Directive24 V DC plus or minus 10 % Ripple P-P 10 % or less80 mA or less (at 24 V) (without connected sensor amplifiers)Wire-saving connector 2 A
(Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
n/a
design engineersPanasonicSC-GU3-02
Maximum of 16 units per SC-GU3-02 unit
(Max. 12 units when FX-500 / LS-500 series are connected) (Max. 12 units when FX-500 / LS-500 series are connected)
–10 to +55 ℃ +14 to +131 ℉ (No dew ondensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RHEnclosure: PolycarbonateNet weight: 75 g approx.
Gross weight: 120 g approx.
EMC Directive, RoHS Directive11 to 25 V DC Ripple P-P 10 % or less100 mA or less (without connected sensor amplifiers)Wire-saving connector 2A
(Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
DeviceNet compliant
design engineersPanasonicSC-GU3-01
Maximum of 16 units per SC-GU3-01 unit
(Max. 12 units when FX-500 / LS-500 series are connected) (Max. 12 units when FX-500 / LS-500 series are connected)
–10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RHEnclosure: PolycarbonateNet weight: 80 g approx.
Gross weight: 120 g approx.
EMC Directive, RoHS Directive24V DC +10/-15% Ripple P-P 10 % or less120 mA or less (without connected sensor amplifiers)Wire-saving connector 2 A (Note 1), supply connector 6 A (Note 2)
(Note 1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.
(Note 2) In case of supplying power to other devices, be sure to set the current less than allowable passing current.
CC-Link Ver.1.10
design engineersPanasonicSC-E82
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicSC-E81
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicSC-E1
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicSC-A02
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicSC-A01
n/an/an/an/an/an/an/an/an/an/a
design engineersPanasonicSC-71
Max. 16 units per 1 communication unit-10 to +55degrees +14 to +131degrees Fahrenheit (If 4 to 7 units are connected in cascade: -10 to +50degrees +14 to +122degrees Fahrenheit , if 8 to 16 units are connected in cascade: -10 to +45degrees +14 to +113degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -20 to +70degrees - 4 to +158degrees Fahrenheit35 to 85 % RH, Storage: 35 to 85 % RHEnclosure: Polycarbonate
Metal plate: Aluminum
Net weight: 10 g approx.
Gross weight: 25 g approx.
n/an/an/an/an/a

Related Documents

Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › Communication Unit for CC-Link IE Field / CC-Link@@@@SC-GU3-04 / SC-HG1-CEF / SC-GU3-01 / SC-HG1-CCommunication Unit for CC-Link IE Field / CC-Link@@@@SC-GU3-04 / SC-HG1-CEF / SC-GU3-01 / SC-HG1-C
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › FX-100 Sensing Characteristics Data sheetFX-100 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › FX-100 Sensing rangeFX-100 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › FX-300 Sensing Characteristics Data sheetFX-300 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › FX-300 Sensing rangeFX-300 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › FX-311 Sensing rangeFX-311 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › FX-410 Sensing rangeFX-410 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › FX-500 Sensing Characteristics Data sheetFX-500 Sensing Characteristics Data sheet
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › FX-500 Sensing rangeFX-500 Sensing range
Sensors › Factory Automation Sensors › Fiber Sensors › Communication Unit for Open Network SC-GU3 › SC-GU3SC-GU3