Inductive Proximity Sensors: Compact Micro-size Inductive Proximity Sensor GS

Model List

Found 11 matches. Display 1 - 11 matches.
Part No.sort ascendingData SheetApplicable amplifierMax. operation distanceStable sensing rangeStandard sensing objectHysteresisRepeatabilityProtectionAmbient temperatureAmbient humidityVibration resistanceParts Inventory
   Column active Filter
Close

Filter by Applicable amplifier

Column active Filter
Close

Filter by Max. operation distance

Column active Filter
Close

Filter by Stable sensing range

Column active Filter
Close

Filter by Standard sensing object

Column active Filter
Close

Filter by Hysteresis

Column active Filter
Close

Filter by Repeatability

Column active Filter
Close

Filter by Protection

Column active Filter
Close

Filter by Ambient temperature

Column active Filter
Close

Filter by Ambient humidity

Column active Filter
Close

Filter by Vibration resistance

 
design engineersPanasonicGS-8S
GA-2, GA-2R, GA-2D4 mm 0.157 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2 mm 0 to 0.079 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in50 μm 1.969 mil or less5 μm 0.197 mil
or less
(Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉35 to 95 % RH, Storage: 35 to 95 % RH10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
design engineersPanasonicGS-8M
GA-2, GA-2R, GA-2D3.5 mm 0.138 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.5 mm 0 to 0.059 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in50 μm 1.969 mil or less3μm 0.118 mil
or less
(Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉35 to 95 % RH, Storage: 35 to 95 % RH10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
design engineersPanasonicGS-5S
GA-2, GA-2R, GA-2D3 mm 0.118 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1mm 0 to 0.039 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in50 μm 1.969 mil or less2.5 μm 0.098 mil
or less
(Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉35 to 95 % RH, Storage: 35 to 95 % RH10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
design engineersPanasonicGS-3S
GA-2, GA-2R, GA-2D2 mm 0.079 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 0.8 mm 0 to 0.031 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in50 μm 1.969 mil or less2 μm 0.079 mil
or less
(Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉35 to 95 % RH, Storage: 35 to 95 % RH10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
design engineersPanasonicGS-14T
GA-2, GA-2R, GA-2D8 mm 0.315 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5 mm 0 to 0.197 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in70 μm 2.756 mil or less5 μm 0.197 mil
or lesss
(Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉35 to 95 % RH, Storage: 35 to 95 % RH10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
design engineersPanasonicGS-14M
GA-2, GA-2R, GA-2D8 mm 0.315 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5 mm 0 to 0.197 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in70 μm 2.756 mil or less5 μm 0.197 mil
or less
(Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉35 to 95 % RH, Storage: 35 to 95 % RH10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
design engineersPanasonicGS-12M
GA-2, GA-2R, GA-2D6 mm 0.236 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 3 mm 0 to 0.118 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in60 μm 2.362 mil or less5 μm 0.197 mil
or less
(Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉35 to 95 % RH, Storage: 35 to 95 % RH10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
design engineersPanasonicGS-10M
GA-2, GA-2R, GA-2D4 mm 0.157 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2 mm 0 to 0.079 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in50 μm 1.969 mil or less5 μm 0.197 mil
or less
(Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉35 to 95 % RH, Storage: 35 to 95 % RH10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
design engineersPanasonicGA-2R
n/an/an/an/an/an/an/a-10 to +60 ℃ -14 to +140 ℉ (No dew condensation or icing allowed),
Storage: -10 to +60 ℃ -14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RHn/a
design engineersPanasonicGA-2D
n/an/an/an/an/an/an/a-10 to +60 ℃ -14 to +140 ℉ (No dew condensation or icing allowed),
Storage: -10 to +60 ℃ -14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RHn/a
design engineersPanasonicGA-2
n/an/an/an/an/an/an/a-10 to +60 ℃ -14 to +140 ℉ (No dew condensation or icing allowed),
Storage: -10 to +60 ℃ -14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RHn/a