Inductive Proximity Sensors: Cylindrical Inductive Proximity Sensor GX-U/GX-FU/GX-N

Model List

Found 75 matches. Display 16 - 30 matches.
Part No.sort descendingData SheetMax. operation distanceStable sensing rangeStandard sensing objectHysteresisSupply voltageCurrent consumptionOutputOutput:Short-circuit protectionMax. response frequencyOperation indicatorParts Inventory
   Column active Filter
Close

Filter by Max. operation distance

Column active Filter
Close

Filter by Stable sensing range

Column active Filter
Close

Filter by Standard sensing object

Column active Filter
Close

Filter by Hysteresis

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Output

Column active Filter
Close

Filter by Output:Short-circuit protection

Column active Filter
Close

Filter by Max. response frequency

Column active Filter
Close

Filter by Operation indicator

 
design engineersPanasonicGX-18MLUB
15 mm 0.591 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated350 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-18MLUB-C5
15 mm 0.591 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated350 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-18MLUB-J
15 mm 0.591 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated350 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-18MU
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated500 HzNormally closed type: Orange LED (lights up when the output is ON)
design engineersPanasonicGX-18MU-C5
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated500 HzNormally closed type: Orange LED (lights up when the output is ON)
design engineersPanasonicGX-18MU-J
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated500 Hzn/a
design engineersPanasonicGX-18MUB
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated500 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-18MUB-C5
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated500 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-18MUB-J
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated500 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-30MLU
22 mm 0.866 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated220 HzNormally closed type: Orange LED (lights up when the output is ON)
design engineersPanasonicGX-30MLU-C5
22 mm 0.866 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated220 HzNormally closed type: Orange LED (lights up when the output is ON)
design engineersPanasonicGX-30MLU-J
22 mm 0.866 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated220 Hzn/a
design engineersPanasonicGX-30MLUB
22 mm 0.866 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated220 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-30MLUB-C5
22 mm 0.866 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated220 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-30MLUB-J
22 mm 0.866 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated220 HzOrange LED (lights up when the output is ON)

Pages