Inductive Proximity Sensors: Micro-size Inductive Proximity Sensor GXL

Model List

Found 189 matches. Display 46 - 60 matches.
Part No.sort descendingData SheetCE marking directive complianceMax. operation distanceStable sensing rangeStandard sensing objectHysteresisRepeatabilitySupply voltageCurrent consumptionOutputOutput:Utilization categoryParts Inventory
   Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Max. operation distance

Column active Filter
Close

Filter by Stable sensing range

Column active Filter
Close

Filter by Standard sensing object

Column active Filter
Close

Filter by Hysteresis

Column active Filter
Close

Filter by Repeatability

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Output

Column active Filter
Close

Filter by Output:Utilization category

 
design engineersPanasonicGXL-15HLUIB-C5
EMC Directive, RoHS Directive8 mm 0.315 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HLUIB-R
EMC Directive, RoHS Directive8 mm 0.315 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HLUIB-R-C5
EMC Directive, RoHS Directive8 mm 0.315 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HU
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HU-C5
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HU-R
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HU-R-C5
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HUB
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HUB-C5
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HUB-R
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HUB-R-C5
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HUI
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HUI-C5
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HUI-R
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13
design engineersPanasonicGXL-15HUI-R-C5
EMC Directive, RoHS Directive5 mm 0.197 in plus or minus 10%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 4 mm 0 to 0.157 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance(with standard sensing object)Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 100 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
DC-12 or DC-13

Pages