GD-C3 design engineers Panasonic

Part No: GD-C3

Specifications

ItemPerformance characteristics
TypeSmall object detection
Supply voltage12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Current consumption12 V DC: 700 mA or less, 24 V DC: 400 mA or less
Outputs (OUT-1 , OUT-2 , ALM. , Answer-back )NPN open-collector transistor
-Maximum sink current: 100 mA
-Applied voltage: 30 V DC or less (between output and 0 V)
-Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : OUT-1OFF above the one-sheet threshold level
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : OUT-2OFF above the two-sheet threshold level
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : ALM.OFF when an error occurs
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Short-circuit protectionIncorporated
Response time5 ms or less
Set level storage functionSet values of eight channels stored
Set level teaching functionIncorporated
External setting functionIncorporated
Indicators : PowerGreen LED (lights up when the power is ON)
Indicators : Self-diagnosis (ALM.)Red LED (lights up during SET mode and when an error occurs during RUN mode)
Indicators : Sensing mode (SENSE)2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode)
Indicators : OUT-1Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode)
Indicators : OUT-2Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode)
Indicators : Sensing levelYellow LED x 1 and green LED x 6 (indicate the sensing level)
Timer functionApprox. 50 ms fixed delay timer (switchable either effective or ineffective)
Environmental resistance : Ambient temperature-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉
Environmental resistance : Ambient humidity45 to 85 % RH, Storage: 35 to 90 % RH
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Environmental resistance : Vibration resistance10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Environmental resistance : Shock resistance300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
MaterialHeat-resistant ABS
WeightNet weight: 440 g approx.
AccessoryInsulation plate: 2 pcs.

Parts InventoryParts Inventory

Searching inventory

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.

Related Documents

Sensors › Factory Automation Sensors › Laser Measurement Sensors › Metal-sheet Double-feed Detector GD › GD-C3 › Data sheetData Sheet
Sensors › Factory Automation Sensors › Laser Measurement Sensors › Metal-sheet Double-feed Detector GD › GD-C3 › GDGD
Sensors › Factory Automation Sensors › Laser Measurement Sensors › Metal-sheet Double-feed Detector GD › GD-C3 › GD-C1/GD-C3GD-C1/GD-C3
Sensors › Factory Automation Sensors › Laser Measurement Sensors › Metal-sheet Double-feed Detector GD › GD-C3 › GD-C1/GD-C3GD-C1/GD-C3
Sensors › Factory Automation Sensors › Laser Measurement Sensors › Metal-sheet Double-feed Detector GD › GD-C3 › GD-C1/GD-C3GD-C1/GD-C3
Sensors › Factory Automation Sensors › Laser Measurement Sensors › Metal-sheet Double-feed Detector GD › GD-C3 › GD-C1/GD-C3GD-C1/GD-C3