Laser Measurement Sensors: Ultra High-speed・High-precision Laser Displacement Sensor HL-C2

Model List

Found 70 matches. Display 1 - 15 matches.
Part No.sort descendingData SheetSetup modeMeasurement center distanceMeasuring rangeResolution [Average number of samples]LinearityTemprerature characteristicsLight sourceBeam diameterParts Inventory
   Column active Filter
Close

Filter by Setup mode

Column active Filter
Close

Filter by Measurement center distance

Column active Filter
Close

Filter by Measuring range

Column active Filter
Close

Filter by Resolution [Average number of samples]

Column active Filter
Close

Filter by Linearity

Column active Filter
Close

Filter by Temprerature characteristics

Column active Filter
Close

Filter by Light source

Column active Filter
Close

Filter by Beam diameter

 
design engineersPanasonicHL-C201FE-MK
Specular reflective10 mm 0.394 inplus or minus 1 mm plus or minus 0.039 in
(Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows.
20 micro s: +0.1 to +1.0 mm +0.004 to +0.039 in
10 micro s: +0.8 to +1.0 mm +0.032 to +0.039 in
0.25 micro m 0.010 mil [256]
(Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance.
plus or minus 0.02 % F.S.
(Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
0.01 % F.S./degreesRed semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Class 1 (IEC / JIS / FDA, Laser Notice No.50),
Max. output: 0.1 mW
20 x 700 micro m 0.787 x 27.559 mil approx.
(Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity.
If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
design engineersPanasonicHL-C203B
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C203B-MK
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C203BE
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C203BE-MK
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C203F
Diffuse reflective
Specular reflective
Diffuse reflective: 30 mm 1.181 in
Specular reflective: 26.4 mm 1.039 in
Diffuse reflective: plus or minus 5 mm plus or minus 0.197 in
Specular reflective: plus or minus 4.6 mm plus or minus 0.181 in
(Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows.
[Diffuse reflective]
20 micro s: 0 to +5.0 mm 0 to +0.197 in
10 micro s: +3.8 to +5.0 mm +0.150 to +0.197 in
[Specular reflective]
20 micro s: 0 to +4.6 mm 0 to +0.181 in
10 micro s: +3.6 to +4.6 mm +0.142 to +0.181 in
0.1 micro m 0.004 mil [256]
0.025 micro m 0.001 mil [4,096]
(Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance.
plus or minus 0.03 % F.S.
(Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
0.01 % F.S./degreesRed semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Class 2 (IEC / JIS), Class II (FDA)
Max. output: 1 mW
dia. 30 micro m dia. 1.181 mil approx.
(Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity.
If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
design engineersPanasonicHL-C203FE
Diffuse reflective
Specular reflective
Diffuse reflective: 30 mm 1.181 in
Specular reflective: 26.4 mm 1.039 in
Diffuse reflective: plus or minus 5 mm plus or minus 0.197 in
Specular reflective: plus or minus 4.6 mm plus or minus 0.181 in
(Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows.
[Diffuse reflective]
20 micro s: 0 to +5.0 mm 0 to +0.197 in
10 micro s: +3.8 to +5.0 mm +0.150 to +0.197 in
[Specular reflective]
20 micro s: 0 to +4.6 mm 0 to +0.181 in
10 micro s: +3.6 to +4.6 mm +0.142 to +0.181 in
0.25 micro m 0.010 mil [256]
(Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance.
plus or minus 0.03 % F.S.
(Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
0.01 % F.S./degreesRed semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Class 2 (IEC / JIS), Class II (FDA)
Max. output: 1 mW
dia. 30 micro m dia. 1.181 mil approx.
(Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity.
If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
design engineersPanasonicHL-C203FE-MK
Diffuse reflective
Specular reflective
Diffuse reflective: 30 mm 1.181 in
Specular reflective: 26.4 mm 1.039 in
Diffuse reflective: plus or minus 5 mm plus or minus 0.197 in
Specular reflective: plus or minus 4.6 mm plus or minus 0.181 in
(Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows.
[Diffuse reflective]
20 micro s: 0 to +5.0 mm 0 to +0.197 in
10 micro s: +3.8 to +5.0 mm +0.150 to +0.197 in
[Specular reflective]
20 micro s: 0 to +4.6 mm 0 to +0.181 in
10 micro s: +3.6 to +4.6 mm +0.142 to +0.181 in
0.25 micro m 0.010 mil [256]
(Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance.
plus or minus 0.03 % F.S.
(Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured.
0.01 % F.S./degreesRed semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil)
Class 2 (IEC / JIS), Class II (FDA)
Max. output: 1 mW
30 x 1,200 micro m 1.181 x 47.244 mil approx.
(Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity.
If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected.
design engineersPanasonicHL-C205B
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C205B-MK
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C205BE
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C205BE-MK
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C205C
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C205C-MK
n/an/an/an/an/an/an/an/a
design engineersPanasonicHL-C205CE
n/an/an/an/an/an/an/an/a

Pages