Part Number List

Results 75
Models table for series Cylindrical Inductive Proximity Sensor GX-U/GX-FU/GX-N
Part No.DatasheetMax. operation distanceStable sensing rangeStandard sensing objectHysteresisSupply voltageCurrent consumptionOutputOutput:Short-circuit protectionMax. response frequencyOperation indicatorProtectionAmbient TemperatureAmbient HumidityVoltage withstandabilityInsulation resistanceVibration resistanceShock resistanceSensing range variation:Temperature characteristicsSensing range variation:Voltage characteristicsMaterialCableCable ExtensionWeight (Typ.)Accessories2-Color IndicatorOutput:Output operation
8 mm 0.315 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
650 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated)
Sensing part: Nylon
Indicator part: Nylon
0.3 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 55 g approx.
Nut: 2 pcs., Toothed lock washer: 1 pc.
3 mm 0.118 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2.4 mm 0 to 0.094 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
1.2 kHz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated)
Sensing part: Nylon
Indicator part: Nylon
0.3 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 55 g approx.
Nut: 2 pcs., Toothed lock washer: 1 pc.
8 mm 0.315 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
650 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated)
Sensing part: Nylon
Indicator part: Nylon
Nut: 2 pcs., Toothed lock washer: 1 pc.
15 mm 0.591 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
350 Hz
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated)
Sensing part: Nylon
Indicator part: Nylon
Nut: 2 pcs., Toothed lock washer: 1 pc.
Lights up in green under stable sensing condition
lights up in orange under unstable sensing condition
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
500 Hz
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated)
Sensing part: Nylon
Indicator part: Nylon
Nut: 2 pcs., Toothed lock washer: 1 pc.
Lights up in green under stable sensing condition
lights up in orange under unstable sensing condition
4 mm 0.157 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 3.2 mm 0 to 0.126 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
1 kHz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Stainless steel (SUS303)
Sensing part: Nylon
Indicator part: Nylon
Nut: 2 pcs., Toothed lock washer: 1 pc.
2 mm 0.079 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.6 mm 0 to 0.063 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA(Note 1)
- Residual voltage: 3 V or less(Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
1.2 kHz
Normally closed type: Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Stainless steel (SUS303)
Sensing part: Nylon
Indicator part: Nylon
0.15 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 30 g approx.
Nut: 2 pcs., Toothed lock washer: 1 pc.
Lights up in green under stable sensing condition
lights up in orange under unstable sensing condition
2 mm 0.079 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.6 mm 0 to 0.063 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 8 × 8 × t 1 mm 0.315 × 0.315 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA(Note 1)
- Residual voltage: 3 V or less(Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
1.2 kHz
Normally closed type: Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Stainless steel (SUS303)
Sensing part: Nylon
Indicator part: Nylon
Nut: 2 pcs., Toothed lock washer: 1 pc.
Lights up in green under stable sensing condition
lights up in orange under unstable sensing condition
10 mm 0.394 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 8 mm 0 to 0.315 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
350 Hz
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Fluorine resin coated),
Sensing part: Polyarylate (Fluorine resin coated),
Indicator part: Polyarylate
0.3 mm2 2-core spatter-resistant cable, 0.3 m 0.984 ft long with round type connector
Nut: 2 pcs. (Fluorine resin coated),
Toothed lock washer: 1 pc. (Fluorine resin coated)
Lights up in green under stable sensing condition
lights up in orange under unstable sensing condition
Normally open
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
10 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated
300 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉,
Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min.
between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger
between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉
: within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
Enclosure: Brass (Nickel plated)
Sensing part: Nylon
Indicator part: Nylon
Nut: 2 pcs., Toothed lock washer: 1 pc.
Normally closed