Part No.sort descendingData SheetCE marking directive complianceSensing rangeEmission spot size (Typical)Sensing objectMinimum sensing object (Typical)HysteresisRepeatabilityRepeatability (Typical)(perpendicular to sensing axis)Supply voltageCurrent consumptionParts Inventory
   Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Sensing range

Column active Filter
Close

Filter by Emission spot size (Typical)

Column active Filter
Close

Filter by Sensing object

Column active Filter
Close

Filter by Minimum sensing object (Typical)

Column active Filter
Close

Filter by Hysteresis

Column active Filter
Close

Filter by Repeatability

Column active Filter
Close

Filter by Repeatability (Typical)(perpendicular to sensing axis)

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

 
design engineersPanasonicEX-L221-P
EMC Directive, RoHS Directive45 to 300 mm 1.772 to 11.811 in
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
Gold wire of ø0.01 mm ø0.0004 in
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.05 mm 0.0020 in or less0.02 mm 0.0008 in or less
(at 100 to 200 mm sensing distance)
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L221-P-C5
EMC Directive, RoHS Directive45 to 300 mm 1.772 to 11.811 in
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
Gold wire of ø0.01 mm ø0.0004 in
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.05 mm 0.0020 in or less0.02 mm 0.0008 in or less
(at 100 to 200 mm sensing distance)
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L221-P-J
EMC Directive, RoHS Directive45 to 300 mm 1.772 to 11.811 in
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
Gold wire of ø0.01 mm ø0.0004 in
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.05 mm 0.0020 in or less0.02 mm 0.0008 in or less
(at 100 to 200 mm sensing distance)
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L261
EMC Directive, RoHS Directive20 to 50 mm 0.787 to 1.969 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1mm 0.039 in
or less (at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
Gold wire of ø0.01 mm ø0.0004 in
(Note) Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L261-C5
EMC Directive, RoHS Directive20 to 50 mm 0.787 to 1.969 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1mm 0.039 in
or less (at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
Gold wire of ø0.01 mm ø0.0004 in
(Note) Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L261-J
EMC Directive, RoHS Directive20 to 50 mm 0.787 to 1.969 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1mm 0.039 in
or less (at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
Gold wire of ø0.01 mm ø0.0004 in
(Note) Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L261-P
EMC Directive, RoHS Directive20 to 50 mm 0.787 to 1.969 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1mm 0.039 in
or less (at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
Gold wire of ø0.01 mm ø0.0004 in
(Note) Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L261-P-C5
EMC Directive, RoHS Directive20 to 50 mm 0.787 to 1.969 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1mm 0.039 in
or less (at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
Gold wire of ø0.01 mm ø0.0004 in
(Note) Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L261-P-J
EMC Directive, RoHS Directive20 to 50 mm 0.787 to 1.969 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
dia. 1mm 0.039 in
(at a sensing distance of 50 mm 1.969 in)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
Gold wire of ø0.01 mm ø0.0004 in
(Note) Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L262
EMC Directive, RoHS Directive20 to 70 mm 0.787 to 2.756 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
Approx. 5 × 1 mm 0.197 × 0.039 in (vertical x horizontal)
(at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
n/a20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L262-C5
EMC Directive, RoHS Directive20 to 70 mm 0.787 to 2.756 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
Approx. 5 × 1 mm 0.197 × 0.039 in (vertical x horizontal)
(at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
n/a20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L262-J
EMC Directive, RoHS Directive20 to 70 mm 0.787 to 2.756 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
Approx. 5 × 1 mm 0.197 × 0.039 in (vertical x horizontal)
(at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
n/a20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L262-P
EMC Directive, RoHS Directive20 to 70 mm 0.787 to 2.756 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
Approx. 5 × 1 mm 0.197 × 0.039 in (vertical x horizontal)
(at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
n/a20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L262-P-C5
EMC Directive, RoHS Directive20 to 70 mm 0.787 to 2.756 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
Approx. 5 × 1 mm 0.197 × 0.039 in (vertical x horizontal)
(at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
n/a20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less
design engineersPanasonicEX-L262-P-J
EMC Directive, RoHS Directive20 to 70 mm 0.787 to 2.756 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
Approx. 5 × 1 mm 0.197 × 0.039 in (vertical x horizontal)
(at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
n/a20 % or less of operation distancePerpendicular to sensing axis: 0.2 mm 0.0080 in or lessn/a12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less15 mA or less