Photoelectric Sensors / Laser Sensors: CMOS type Micro Laser Distance Sensor HG-C

Model List

Found 10 matches. Display 1 - 10 matches.
Part No.sort ascendingData SheetApplicable standardMeasurement center distanceMeasuring rangeRepeatabilityLinearityTemprerature characteristicsLight sourceBeam diameterSupply voltageCurrent consumptionParts Inventory
   Column active Filter
Close

Filter by Applicable standard

Column active Filter
Close

Filter by Measurement center distance

Column active Filter
Close

Filter by Measuring range

Column active Filter
Close

Filter by Repeatability

Column active Filter
Close

Filter by Linearity

Column active Filter
Close

Filter by Temprerature characteristics

Column active Filter
Close

Filter by Light source

Column active Filter
Close

Filter by Beam diameter

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

 
design engineersPanasonicHG-C1400-P
EMC Directive Compliance, FDA Standard400 mm 15.748 in±200 mm 7.874 in300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in)
800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in)
±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
0.03% F.S./℃Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ]
Max. output: 1 mW
emission peak wavelength: 655 nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø500 μm 19.6851 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1400
EMC Directive Compliance, FDA Standard400 mm 15.748 in±200 mm 7.874 in300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in)
800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in)
±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
0.03% F.S./℃Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ]
Max. output: 1 mW
emission peak wavelength: 655 nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø500 μm 19.6851 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1200-P
EMC Directive Compliance, FDA Standard200 mm 7.874 in±80 mm 3.150 in200 μm 7.874 mil±0.2%F.S.0.03% F.S./℃Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ]
Max. output: 1 mW
emission peak wavelength: 655 nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø300 μm 11.8111 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1200
EMC Directive Compliance, FDA Standard200 mm 7.874 in±80 mm 3.150 in200 μm 7.874 mil±0.2%F.S.0.03% F.S./℃Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ]
Max. output: 1 mW
emission peak wavelength: 655 nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø300 μm 11.8111 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24 V DC ±10 %, Ripple P-P 10 % or less40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1100-P
EMC Directive Compliance, FDA Standard100mm 3.937 in±35mm 1.328 in70 μm 2.756 mil±0.1%F.S.0.03% F.S. /℃Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note)
Max. output: 1mW
emission peak wavelength: 655nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø120 μm 4.7241 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1100
EMC Directive Compliance, FDA Standard100mm 3.937 in±35mm 1.328 in70 μm 2.756 mil±0.1%F.S.0.03% F.S. /℃Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note)
Max. output: 1mW
emission peak wavelength: 655nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø120 μm 4.7241 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1050-P
EMC Directive Compliance, FDA Standard50mm 1.969 in±15mm 0.591 in30 μm 1.181 mil±0.1%F.S.0.03% F.S. /℃Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note)
Max. output: 1mW
emission peak wavelength: 655nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø70 μm 1.1811 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1050
EMC Directive Compliance, FDA Standard50mm 1.969 in±15mm 0.591 in30 μm 1.181 mil±0.1%F.S.0.03% F.S. /℃Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note)
Max. output: 1mW
emission peak wavelength: 655nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø70 μm 1.1811 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1030-P
EMC Directive Compliance, FDA Standard30mm 1.181 in±5mm 0.197 in10 μm 0.394 mil±0.1%F.S.0.03% F.S. /℃Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note)
Max. output: 1mW
emission peak wavelength: 655nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø50 μm 1.969 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
design engineersPanasonicHG-C1030
EMC Directive Compliance, FDA Standard30mm 1.181 in±5mm 0.197 in10 μm 0.394 mil±0.1%F.S.0.03% F.S. /℃Red semiconductor laser Class 2 (JIS / IEC / GB) / Class II (FDA)(Note)
Max. output: 1mW
emission peak wavelength: 655nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
ø50 μm 1.969 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
12 to 24V DCplus or minus 10% Ripple P-P 10%40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)