Photoelectric Sensors / Laser Sensors: Compact Multi-voltage Photoelectric Sensor NX5

Model List

Found 20 matches. Display 1 - 15 matches.
Part No.sort descendingData SheetCE marking directive complianceSensing rangeSensing objectHysteresisRepeatability(perpendicular to sensing axis)Supply voltagePower consumptionOutputOutput:Output operationResponse timeParts Inventory
   Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Sensing range

Column active Filter
Close

Filter by Sensing object

Column active Filter
Close

Filter by Hysteresis

Column active Filter
Close

Filter by Repeatability(perpendicular to sensing axis)

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Power consumption

Column active Filter
Close

Filter by Output

Column active Filter
Close

Filter by Output:Output operation

Column active Filter
Close

Filter by Response time

 
design engineersPanasonicNX5-D700A
Low Voltage Directive, EMC Directive, RoHS Directive700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less2 VA or lessRelay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON10 ms or less
design engineersPanasonicNX5-D700B
Low Voltage Directive, EMC Directive, RoHS Directive700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less2 VA or lessRelay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less
design engineersPanasonicNX5-M10RB
Low Voltage Directive, EMC Directive, RoHS Directive10 m 32.808 ftdia. 20 mm dia. 0.787 in or more opaque object
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
n/a0.1 mm 0.004 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or lessEmitter: 1 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less
design engineersPanasonicNX5-M10RB-C5
Low Voltage Directive, EMC Directive, RoHS Directive10 m 32.808 ftdia. 20 mm dia. 0.787 in or more opaque object
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
n/a0.1 mm 0.004 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or lessEmitter: 1 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less
design engineersPanasonicNX5-M30A
Low Voltage Directive, EMC Directive, RoHS Directive30 m 98.425 ftdia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or lessEmitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON10 ms or less
design engineersPanasonicNX5-M30B
Low Voltage Directive, EMC Directive, RoHS Directive30 m 98.425 ftdia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or lessEmitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less
design engineersPanasonicNX5-D700A-C5
Low Voltage Directive, EMC Directive, RoHS Directive700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.3 mm 0.012 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less2 VA or lessRelay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON10 ms or less
design engineersPanasonicNX5-M10RA-C5
Low Voltage Directive, EMC Directive, RoHS Directive10 m 32.808 ftdia. 20 mm dia. 0.787 in or more opaque object
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
n/a0.1 mm 0.004 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or lessEmitter: 1 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON10 ms or less
design engineersPanasonicNX5-M30A-C5
Low Voltage Directive, EMC Directive, RoHS Directive30 m 98.425 ftdia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or lessEmitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON10 ms or less
design engineersPanasonicNX5-M30B-C5
Low Voltage Directive, EMC Directive, RoHS Directive30 m 98.425 ftdia. 20 mm dia. 0.787 in or more opaque object (Completely beam interrupted object)
(Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or lessEmitter: 1.5 VA or less
Receiver: 2 VA or less
Relay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less
design engineersPanasonicNX5-PRVM5B
Low Voltage Directive, EMC Directive, RoHS Directive0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less2 VA or lessRelay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less
design engineersPanasonicNX5-PRVM5B-C5
Low Voltage Directive, EMC Directive, RoHS Directive0.1 to 5 m 0.328 to 16.404 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less2 VA or lessRelay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less
design engineersPanasonicNX5-RM7A-C5
Low Voltage Directive, EMC Directive, RoHS Directive0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque or translucent object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less2 VA or lessRelay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Light-ON10 ms or less
design engineersPanasonicNX5-RM7B
Low Voltage Directive, EMC Directive, RoHS Directive0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque or translucent object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less2 VA or lessRelay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less
design engineersPanasonicNX5-RM7B-C5
Low Voltage Directive, EMC Directive, RoHS Directive0.1 to 7 m 0.328 to 22.966 ft
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque or translucent object
(Note) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
n/a0.2 mm 0.008 in or less24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less2 VA or lessRelay contact 1 c
- Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load)
- Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour)
- Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour)
Dark-ON10 ms or less