Photoelectric Sensors / Laser Sensors: Leak Detection Sensor EX-F70/EX-F60

Model List

Found 22 matches. Display 1 - 15 matches.
Part No.sort descendingData SheetSensing objectApplicable connectorSupply voltageCurrent consumptionOutputOutput:Output operationOutput:Short-circuit protectionResponse timeInput No.Parts Inventory
   Column active Filter
Close

Filter by Sensing object

Column active Filter
Close

Filter by Applicable connector

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Output

Column active Filter
Close

Filter by Output:Output operation

Column active Filter
Close

Filter by Output:Short-circuit protection

Column active Filter
Close

Filter by Response time

Column active Filter
Close

Filter by Input No.

 
design engineersPanasonicEX-F61-C5
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less15 mA or lessNPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F61-PN
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less15 mA or lessPNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F62-C5
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less15 mA or lessNPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F62-PN
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less15 mA or lessPNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F62-PN-C5
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less15 mA or lessPNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F71
Water, Fluorinert™
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less10 mA or less(PNP output type: 15 mA or less)NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F71-C5
Water, Fluorinert™
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less10 mA or less(PNP output type: 15 mA or less)NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F72
Water, Fluorinert™
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less10 mA or less(PNP output type: 15 mA or less)NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F72-C5
Water, Fluorinert™
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less10 mA or less(PNP output type: 15 mA or less)NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-F72-PN-C5
Water, Fluorinert™
Note:Highly viscous liquid may not be detected stably.
Note:Fluorinert is the world wide trademark of 3M.
n/a12 to 24 V DC ± 10 % Ripple P-P 10 % or less10 mA or less(PNP output type: 15 mA or less)PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
In normal state: ON, When leak detected or the sensor is mounted improperly: OFFIncorporated50 ms or lessn/a
design engineersPanasonicEX-FC1
n/aSL-CP112 to 24 V DC ± 10 % Ripple P-P 10 % or less50 mA or less (for the unit itself), 135 mA or less (including the sensor input current when all outputs of sensors are ON)Relay contact 1a
- Switching capacity: 30 V 1 A DC (resistive load)
- Min. applied load: 10 mV 10 μA DC
- Electrical lifetime: 100,000 switching operations or more (rated load, switching frequency 20 operations/min.)
- Mechanical lifetime: 50 million switching operations or more (switching frequency 180 operations/min.)
The output relay is ON when the input signal from the sensor is ON
Note : Even with only one leak detection sensor connected, an OFF signal is output if the sensor detects liquid leakage, or if the unit has been installed incorrectly.
n/a5 ms or less (excluding the response time of the sensor)8 Nos.
design engineersPanasonicMS-EX-F6-1
n/an/an/an/an/an/an/an/an/a
design engineersPanasonicMS-EX-F6-2
n/an/an/an/an/an/an/an/an/a
design engineersPanasonicMS-EX-F7-1
n/an/an/an/an/an/an/an/an/a
design engineersPanasonicMS-EX-F7-2
n/an/an/an/an/an/an/an/an/a

Pages