Photoelectric Sensors / Laser Sensors: Pipe-mountable Liquid Level Detection Sensor EX-F1

Model List

Found 2 matches. Display 1 - 2 matches.
Part No.sort descendingData SheetCE marking directive complianceSensing objectApplicable pipe diameterSupply voltageCurrent consumptionOutputOutput:Output operationOutput:Short-circuit protectionResponse timeOperation indicatorParts Inventory
   Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Sensing object

Column active Filter
Close

Filter by Applicable pipe diameter

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Output

Column active Filter
Close

Filter by Output:Output operation

Column active Filter
Close

Filter by Output:Short-circuit protection

Column active Filter
Close

Filter by Response time

Column active Filter
Close

Filter by Operation indicator

 
design engineersPanasonicEX-F1-C5
EMC Directive, RoHS DirectiveLiquid
(Note):Unclear or highly viscous liquid may not be detected stably.
Outer dia. ø6 to ø13 mm ø0.236 to ø0.512 in transparent resin pipe
[PFA (Fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in ]
(Note:Do not use the sensor with pipes other than the above specified.)
12 to 24 V DC ± 10 % Ripple P-P 10 % or less30 mA or less
(Note:Unclear or highly viscous liquid may not be detected stably.)
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Switchable either Light-ON (Liquid-absent-ON) or Dark-ON (Liquid-present-ON)Incorporated2 ms or lessRed LED (lights up when the output is ON)
design engineersPanasonicEX-F1
EMC Directive, RoHS DirectiveLiquid
(Note):Unclear or highly viscous liquid may not be detected stably.
Outer dia. ø6 to ø13 mm ø0.236 to ø0.512 in transparent resin pipe
[PFA (Fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in ]
(Note:Do not use the sensor with pipes other than the above specified.)
12 to 24 V DC ± 10 % Ripple P-P 10 % or less30 mA or less
(Note:Unclear or highly viscous liquid may not be detected stably.)
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Switchable either Light-ON (Liquid-absent-ON) or Dark-ON (Liquid-present-ON)Incorporated2 ms or lessRed LED (lights up when the output is ON)