Specification

Specifications table for model GX-F12BI-P-C5
ItemPerformance characteristics
Max. Operation Distance4.0 mm 0.158 in plus or minus 8 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
Stable Sensing Range0 to 3.3 mm 0 to 0.130 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Standard Sensing Object Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in
Hysteresis20 % or less of operation distance(with standard sensing object)
RepeatabilityAlong sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
Supply Voltage 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less
Current Consumption15 mA or less
OutputPNP open-collector transistor
- Maximum source current: 100 mA
- Applied voltage: 30 V DC or less(between output and +V)
- Residual voltage: 2 V or less (at 100 mA source current)
Output: Output Operation Normally closed
Output: Utilization Category DC-12 or DC-13
Max. Response Frequency500 Hz
Operation Indicator Orange LED(lights up when the output is ON)
Ambient Temperature-25 to +70 ℃ -13 to +158 ℉ , Storage: - 40 to +85 ℃ - 40 to +185 ※
ProtectionIP68 (IEC), IP68g (JEM)
(Note) Panasonic Electric Works SUNX's IP68 test method
1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min.
2. Regard the heat shock test in 1 as one cycle and perform 20 cycles.
3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.
4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values.
(Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Ambient Humidity45 to 85 % RH, Storage: 35 to 95 % RH
Voltage Withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation Resistance50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration Resistance10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each
Shock Resistance10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each
Sensing Range Variation: Temperature Characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158degrees Fahrenheit: Within plus or minus 8 % of sensing range at +23 ℃ +73 ℉
Sensing Range Variation: Voltage Characteristics Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage
MaterialEnclosure: PBT
Indicator part: Polyester
Cable ExtensionExtension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net Weight 20 g approx.
CE Marking Directive ComplianceEMC Directive, RoHS Directive