Specification

Specifications table for model GXL-8HUI-C5
ItemPerformance characteristics
CE Marking Directive ComplianceEMC Directive, RoHS Directive
Max. Operation Distance2.5 mm 0.098 in plus or minus 20%
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
Stable Sensing Range0 to 1.8 mm 0 to 0.071 in
(Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Standard Sensing Object Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in
Hysteresis20 % or less of operation distance(with standard sensing object)
RepeatabilityAlong sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
Supply Voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Current Consumption0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
OutputNon-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies with the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable. The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
Output: Utilization Category DC-12 or DC-13
Output: Short-Circuit ProtectionIncorporated
Max. Response Frequency1 kHz
Environmental Resistance: Pollution Degree3 (Industrial environment)
2-Color IndicatorLights up in green under stable sensing condition
Lights up in red under unstable sensing condition
ProtectionIP67 (IEC), IP67 g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
Ambient Temperature-25 to +70 ℃ -13 to +158 ℉ , Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient Humidity45 to 85 % RH, Storage: 35 to 95 % RH
Voltage Withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation Resistance50 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration Resistance10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock Resistance1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Sensing Range Variation: Temperature Characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within+15-10 % of sensing range at +20 ℃ +68 ℉
Sensing Range Variation: Voltage Characteristics Within plus or minus 2 % for plus or minus 10 % fluctuation of the supply voltage
MaterialEnclosure: PBT
Indicator part: Polyarylate
Net Weight Net weight: 12 g approx.
AccessoriesMS-GXL8-4(Sensor mounting bracket): 1 set

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.

Panasonic assumes no responsibility for any dealings you may have with distributors.