Integrated Display Type Digital Flow Sensor FM-200

Panasonic offers a Digital Flow Sensor with integrated display for a wide range of applications. The FM-200 Series can control and effectively manage flows using a variety of output modes.

The setting conditions appear on the sub-display making it much easier to keep track of operations. In addition, the 2-color digital display shows the Sensor’s operation status at a glance.

A new rectification mechanism and Micro Electro-Mechanical System (MEMS) technology allows Panasonic's Digital Flow Sensor to be mounted on a silicon Sensor chip resulting in extremely small heat capacity, high precision of ±3% F.S. and high-speed response. Two temperature Sensors, one on either side of the heater, detect heat distribution and make bidirectional detection possible.

Characteristics

  • Easy-To-Read 2-Color Display With Sub Display
  • High Precision Of ±3 % F.S.
  • One Sensor For Both Intake And Exhaust
  • High Flow-Rate Type For Up To 1000 l/min
  • Integrated Value Reset Function
  • Analog Voltage And Digital Outputs
  • Key Lock Function
  • Rattle Prevention Function (Response Time Setting)
  • Display Rate Setting
  • ECO Mode

Part Number List

Results 18
Models table for series Integrated Display Type Digital Flow Sensor FM-200
Part No.DatasheetCE Marking Directive ComplianceFull Scale Flow RateInstant Flow Rate: Display RangeInstant Flow Rate: Setting and Display ResolutionIntegrated Flow Rate: Display RangeIntegrated Flow Rate: Setting and Display ResolutionSpecified Integrated ValuePort SizeRated Pressure Range Weight (Typ.)Pressure WithstandabilityApplicable FluidSupply Voltage Current ConsumptionComparative OutputComparative Output: Output ModesComparative Output: Short-Circuit ProtectionComparative Output: HysteresisComparative Output: Response TimeAnalog Voltage OutputRepeatabilityAccuracy Assurance RangeExternal InputLinearityDisplayProtectionAmbient TemperatureAmbient HumidityVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceTemperature Characteristics Pressure CharacteristicsEnclosure EarthingMaterialConnecting MethodCable LengthAccessories
EMC Directive, RoHS Directive
10 ℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-11 to +11 ℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.01 ℓ/min.
±99999.99 ℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.01 ℓ
0.1 ℓ
ø4 ø0.157 push-in
-0.09 to +0.7 MPa
Net weight: 50 g approx., Gross weight: 115 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
NPN open-collector transistor
・Maximum sink current: 50 mA or less
・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)
・Residual voltage: 2.4 V or less (at 50 mA sink current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: 0 to +0.4 V
OFF voltage: +5 V to +V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
100 ℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-110 to +110 ℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.1 ℓ/min.
±999999.9 ℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.1 ℓ
1 ℓ
ø8 ø0.315 push-in
-0.09 to +0.7 MPa
Net weight: 70 g approx., Gross weight: 135 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
NPN open-collector transistor
・Maximum sink current: 50 mA or less
・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)
・Residual voltage: 2.4 V or less (at 50 mA sink current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: 0 to +0.4 V
OFF voltage: +5 V to +V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
500 ℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-550 to +550 ℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 ℓ/min.
±9999999 ℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 ℓ
5 ℓ
Rc1/2 female thread
-0.09 to +0.7 MPa
Net weight: 155 g approx., Gross weight: 220 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
PNP open-collector transistor
・Maximum source current: 50 m A or less
・Applied voltage: 26.4 V DC or less(between comparative output and +V)
・Residual voltage: 2.4 V or less (at 50 mA source current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: +5 V to +V
OFF voltage: 0 to +0.6 V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
500 ℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-550 to +550 ℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 ℓ/min.
±9999999 ℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 ℓ
5 ℓ
Rc1/2 female thread
-0.09 to +0.7 MPa
Net weight: 155 g approx., Gross weight: 220 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
NPN open-collector transistor
・Maximum sink current: 50 mA or less
・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)
・Residual voltage: 2.4 V or less (at 50 mA sink current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: 0 to +0.4 V
OFF voltage: +5 V to +V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
50 ℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-55 to +55 ℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.1 ℓ/min.
±999999.9 ℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.1 ℓ
0.5 ℓ
ø8 ø0.315 push-in
-0.09 to +0.7 MPa
Net weight:70 g approx., Gross weight: 135 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
PNP open-collector transistor
・Maximum source current: 50 m A or less
・Applied voltage: 26.4 V DC or less(between comparative output and +V)
・Residual voltage: 2.4 V or less (at 50 mA source current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: +5 V to +V
OFF voltage: 0 to +0.6 V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
5 ℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-5.5 to +5.5 ℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.01 ℓ/min.
±99999.99 ℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.01 ℓ
0.05 ℓ
ø4 ø0.157 push-in
-0.09 to +0.7 MPa
Net weight: 50 g approx., Gross weight: 115 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
PNP open-collector transistor
・Maximum source current: 50 m A or less
・Applied voltage: 26.4 V DC or less(between comparative output and +V)
・Residual voltage: 2.4 V or less (at 50 mA source current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: +5 V to +V
OFF voltage: 0 to +0.6 V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
500 mℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-550 to +550 mℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 mℓ/min.
±9999999 mℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 mℓ
5 mℓ
ø4 ø0.157 push-in
-0.09 to +0.7 MPa
Net weight: 50 g approx., Gross weight: 115 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
NPN open-collector transistor
・Maximum sink current: 50 mA or less
・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)
・Residual voltage: 2.4 V or less (at 50 mA sink current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: 0 to +0.4 V
OFF voltage: +5 V to +V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
1,000 ℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-1,100 to +1,100 ℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 ℓ/min.
±9999999 ℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 ℓ
10ℓ
G1/2 female thread
-0.09 to +0.7 MPa
Net weight: 155 g approx., Gross weight: 220 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
PNP open-collector transistor
・Maximum source current: 50 m A or less
・Applied voltage: 26.4 V DC or less(between comparative output and +V)
・Residual voltage: 2.4 V or less (at 50 mA source current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: +5 V to +V
OFF voltage: 0 to +0.6 V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
100 ℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-110 to +110 ℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.1 ℓ/min.
±999999.9 ℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
0.1 ℓ
1 ℓ
ø8 ø0.315 push-in
-0.09 to +0.7 MPa
Net weight: 70 g approx., Gross weight: 135 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
PNP open-collector transistor
・Maximum source current: 50 m A or less
・Applied voltage: 26.4 V DC or less(between comparative output and +V)
・Residual voltage: 2.4 V or less (at 50 mA source current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: +5 V to +V
OFF voltage: 0 to +0.6 V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
EMC Directive, RoHS Directive
1,000 mℓ/min.
(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
-1,100 to +1,100 mℓ/min.
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 mℓ/min.
±9999999 mℓ
(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
1 mℓ
10 mℓ
ø4 ø0.157 push-in
-0.09 to +0.7 MPa
Net weight: 50 g approx., Gross weight: 115 g approx.
1 MPa
Clean air, compressed air, nitrogen gas
(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
12 to 24 V DC ± 10 % Ripple P-P10 % or less
Normal mode: 60 mA or less, ECO mode: 40 mA or less
PNP open-collector transistor
・Maximum source current: 50 m A or less
・Applied voltage: 26.4 V DC or less(between comparative output and +V)
・Residual voltage: 2.4 V or less (at 50 mA source current)
Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Incorporated
Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.
[Refer to "Analog voltage output" for more details.]
Within ±1 % F.S.
Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.
One-side direction : +3 to +100 % F.S.
(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
ON voltage: +5 V to +V
OFF voltage: 0 to +0.6 V, or open
Input time: 80 ms or more
Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
IP40 (IEC)
0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 90 % RH, Storage: 35 to 90 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or 49 m/s2 max. acceleration, in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Floating
(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Connector
Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.