Specification

Specifications table for model SH-33R
ItemPerformance characteristics
Applicable AmplifiersSU-7 series
Sensing Range 2 m 6.562 ft
Sensing Object Min. ø1 mm ø0.039 in opaque object (with 2 m 6.562 ft setting distance and at the optimum sensitivity)
Note : The optimum sensitivity stands for the sensitivity level when the operation indicator just lights up in the light received condition.
Hysteresis-
Repeatability (Perpendicular to Sensing Axis) 0.1 mm 0.004 in or less
Operation Indicator Red LED(lights up when the sensing output of the amplifier is ON, incorporated on the emitter of the thru-beam type sensor head)
ProtectionIP66 (IEC)
Ambient Temperature-25 to +60 ℃ -13 to +140 ℉ (No dew condensation or icing allowed)
Storage: -30 to +70 ℃ -22 to +158 ℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient IlluminanceIncandescent light: 3,500 lx or less at the light-receiving face
Vibration Resistance10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock Resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Emitting ElementRed LED (modulated)
Emitting Element: Peak Emission Wavelength680 nm 0.027 mil
MaterialEnclosure: ABS, Lens: Polycarbonate
Cable0.089 mm2 single core shielded cable, 3 m 9.843 ft long
Cable ExtensionExtension up to total 10 m 32.808 ft is possible with an equivalent cable (thru-beam type: both emitter and receiver).
Weight (Typ.)Emitter: 10 g approx.
Receiver: 10 g approx.
Accessory-
RemarkWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.

Stock Check

Important

The service is owned, operated, controlled and managed by Panasonic's distributors.

For pricing, delivery and technical questions related to this service, please direct to them.