Slim Body Automatic Sensitivity Setting Photoelectric Sensor SU-7/SH

Simple automatic sensitivity setting, compact design and quick wire connection makes the NX5 an optimal sensor for most applications.

Part Number List

Results 18
Models table for series Slim Body Automatic Sensitivity Setting Photoelectric Sensor SU-7/SH
Part No.DatasheetApplicable AmplifiersSensing Range Sensing Object HysteresisRepeatability (Perpendicular to Sensing Axis) Applicable Sensor HeadSupply Voltage Current ConsumptionSensing Output Sensing Output: Output OperationSensing Output: Short-Circuit ProtectionSelf-Diagnosis OutputSelf-Diagnosis Output: Output OperationSelf-Diagnosis Output: Short-Circuit ProtectionResponse TimeOperation Indicator Stability IndicatorTest Input (Emission Halt) FunctionExternal Synchronization FunctionRemote Sensitivity Setting Function Remote Sensitivity Selection FunctionSensitivity Shift & Limit Sensitivity Setting FunctionsAutomatic Interference Prevention FunctionTimer Function ProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementEmitting Element: Peak Emission WavelengthMaterialCableCable ExtensionWeight (Typ.)AccessoryRemark
SU-7 series
100 mm 3.937 in
Min. ø1 mm ø0.039 in opaque object (with 100 mm 3.937 in setting distance and at the optimum sensitivity)
Note : The optimum sensitivity stands for the sensitivity level when the operation indicator just lights up in the light received condition.
-
0.1 mm 0.004 in or less
Red LED(lights up when the sensing output of the amplifier is ON, incorporated on the emitter of the thru-beam type sensor head)
IP66 (IEC)
-25 to +60 ℃ -13 to +140 ℉ (No dew condensation or icing allowed)
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Green LED(modulated)
570 nm 0.022 mil
Enclosure: ABS, Lens: Polycarbonate
0.089 mm2 single core shielded cable, 3 m 9.843 ft long
Extension up to total 10 m 32.808 ft is possible with an equivalent cable (thru-beam type: both emitter and receiver).
Emitter: 10 g approx.
Receiver: 10 g approx.
-
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
SU-7 series
300 mm 11.811 in
Min. ø0.3 mm ø0.012 in opaque object (under the optimum condition)
Note : The optimum condition is the condition when the sensitivity is adjusted so that the operation indicator just lights up at the given distance in the light received condition.
-
0.03 mm 0.001 in or less
-
IP62 (IEC)
-10 to +60 ℃ +14 to 140 ℉ (No dew condensation or icing allowed)
Storage : -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate (glass fiber reinforced)
0.057 mm2 single core shielded cable, 3 m 9.843 ft long
Extension up to total 5 m 16.404 ft is possible with an equivalent cable (thru-beam type: both emitter and receiver).
Emitter: 12 g approx.
Receiver: 12 g approx.
Sensor head mounting screw: 2 sets
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
SU-7 series
10 to 14 mm 0.394 to 0.551 in (Convergent point: 12 mm 0.472 in) (Spot diameter: ø1 mm ø0.039 in)
Note : The sensing range and the hysteresis of the mark sensor are specified for white non-glossy paper (50 x 50 mm 1.969 x 1.969 in separatedin) as the object.
Min. 0.2 mm 0.008 in width black line on white paper (with 12 mm 0.472 in setting distance and at the optimum sensitivity)
Note : The optimum sensitivity stands for the sensitivity level when the operation indicator just lights up in the light received condition.
10 % or less of operation distance
Note 2 : The sensing range and the hysteresis of the mark sensor are specified for white non-glossy paper (50 x 50 mm 1.969 x 1.969 in separatedin) as the object.
0.03 mm 0.001 in or less
Red LED (lights up when the sensing output of the amplifier is ON)
-
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
10 to 55 Hz frequency, 3 mm 0.118 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Green LED(modulated)
570 nm 0.022 mil
Enclosure: Polycarbonate, Lens: Acrylic
0.089 mm2 single core, two parallel shielded cables, 2 m 6.562 ft long
Extension up to total 5 m 16.404 ft is possible with an equivalent cable.
20 g approx.
-
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
SU-7 series
10 to 14 mm 0.394 to 0.551 in (Convergent point: 12 mm 0.472 in) (Spot diameter: ø0.7 mm ø0.028 in)
Note : The sensing range and the hysteresis of the mark sensor are specified for white non-glossy paper (50 x 50 mm 1.969 x 1.969 in separatedin) as the object.
Min. 0.07 mm 0.003 in width black line on white paper (with 12 mm 0.472 in setting distance and at the optimum sensitivity)
Note : The optimum sensitivity stands for the sensitivity level when the operation indicator just lights up in the light received condition.
10 % or less of operation distance
Note 2 : The sensing range and the hysteresis of the mark sensor are specified for white non-glossy paper (50 x 50 mm 1.969 x 1.969 in separatedin) as the object.
0.02 mm 0.0008 in or less
Red LED (lights up when the sensing output of the amplifier is ON)
-
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
10 to 55 Hz frequency, 3 mm 0.118 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED (modulated)
680 nm 0.027 mil
Enclosure: Polycarbonate, Lens: Acrylic
0.089 mm2 single core, two parallel shielded cables, 2 m 6.562 ft long
Extension up to total 5 m 16.404 ft is possible with an equivalent cable.
20 g approx.
-
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
SH series
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
35 mA or less

NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between sensing output and 0 V)
・Residual voltage: 1.0 V or less (at 100 mA sink current)
        0.4 V or less (at 16 mA sink current)
Selectable either Light-ON or Dark-ON with the ON and OFF buttons (Selectable with the external inputs for SU-77)
Incorporated

NPN open-collector transistor
・Maximum sink current: 50 mA
・Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
・Residual voltage: 1.0 V or less (at 50 mA sink current)
        0.4 V or less (at 16 mA sink current)
ON under unstable sensing condition (restored automatically after 40 ms approx.), or if the sensing output is short-circuited (restored when short-circuit is rectified).
(For the remote sensitivity adjustment type, it turns ON for 40 ms approx. Also after the remote sensitivity input is received.)
-
0.6 ms or less (0.8 ms or less when the interference prevention function is used)
Red LED (lights up when the sensing output is ON)
Green LED
("RUN" mode: Lights up under stable light received condition or stable dark condition
"SET" mode: At the time of sensitivity setting, blinks twice when the difference between ON and OFF levels is greater than the hysteresis, but blinks 15 times when it is equal to or less than the hysteresis. Also blinks twice after the interference prevention is set
"SET" mode → When "SIF" or "RUN" mode is selected: Blinks from 0 to 5 times according to the sensitivity margin)
-
-
Incorporated
-
Shifts the set sensitivity level
Incorporated
ON-delay / OFF-delay timer (variable 0 to 5 sec.)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Cable lock lever: PPS
0.15 mm2 6-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 65 g approx.
MS-DIN-2 (Amplifier mounting bracket): 1 pc., SU-CT1 (Stripper): 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
SU-7 series
2.5 m 8.202 ft [5 to 80 mm 0.197 to 3.150 in when mounted on optional mounting bracket (MS-SH6-2) and used as convergent reflective type (Conv. point: 25 mm 0.984 in) (Note)]
Note : The sensing range and the hysteresis for the chemical resistant type sensor used in the convergent reflective mode is specified for white non-glossy paper (150 x 150 mm 5.906 x 5.906 in) as the object.
Min. ø5 mm ø0.197 in opaque object
[Min. ø1 mm ø0.039 in steel wire when mounted on optional mounting bracket (MS-SH6-2) and used as convergent reflective type (with 25 mm 0.984 in setting distance and at the max. sensitivity)]
-
[15 % or less of operation distance when mounted on optional mounting bracket (MS-SH6-2) and used as convergent reflective type.(Note)]
Note : The sensing range and the hysteresis for the chemical resistant type sensor used in the convergent reflective mode is specified for white non-glossy paper (150 x 150 mm 5.906 x 5.906 in) as the object.
0.1 mm 0.004 in or less
[0.1 mm 0.004 in or less of operation distance when mounted on optional mounting bracket (MS-SH6-2) and used as convergent reflective type. (with 25 mm 0.984 in setting distance and at the optimum sensitivity(Note))]
Note : The optimum sensitivity stands for the sensitivity level when the operation indicator just lights up in the light received condition.
Orange LED [lights up when the sensing output of the amplifier is ON, incorporated on the emitter]
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 2,000 lx or less at the light-receiving face
10 to 55 Hz frequency, 3 mm 0.118 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED (modulated)
644 nm 0.025 mil
Enclosure: Fluorine resin
Cable sheath: Fluorine resin
0.089 mm2 single core shielded cables, 2 m 6.562 ft long
Extension up to total 5 m 16.404 ft is possible with an equivalent cable (SH-61R: both emitter and receiver).
Emitter: 15 g approx.
Receiver: 15 g approx.
MS-SH6-1 (Sensor head mounting bracket): 2 pcs.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
SU-7 series
0.5 to 7.5 mm 0.020 to 0.295 in (with transparent glass plate)
□24 mm □0.945 in or more transparent glass, aluminum-evaporated mirror, etc.
Note : Make sure to confirm detection with an actual sensor before use.
5 % or less of operation distance
0.03 mm 0.001 in or less (along sensing axis)
-
-
-10 to +60 ℃ +14 to +140 ℉(No dew condensation or icing allowed)
Storage: -10 to +60 ℃ +14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 lx or less at the light-receiving face
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED (modulated)
880 nm 0.035 mil
Enclosure: Polycarbonate
0.089 mm2 single core, two parallel shielded cables, 3 m 9.843 ft long
Extension up to total 5 m 16.404 ft is possible with an equivalent cable.
25 g approx.
-
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
SH series
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
35 mA or less

NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between sensing output and 0 V)
・Residual voltage: 1.0 V or less (at 100 mA sink current)
        0.4 V or less (at 16 mA sink current)
Selectable either Light-ON or Dark-ON with the ON and OFF buttons
Incorporated

NPN open-collector transistor
・Maximum sink current: 50 mA
・Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
・Residual voltage: 1.0 V or less (at 50 mA sink current)
        0.4 V or less (at 16 mA sink current)
ON under unstable sensing condition (restored automatically after 40 ms approx.), or if the sensing output is short-circuited (restored when short-circuit is rectified).
(For the remote sensitivity adjustment type, it turns ON for 40 ms approx. Also after the remote sensitivity input is received.)
-
0.6 ms or less (0.8 ms or less when the interference prevention function is used)
Red LED (lights up when the sensing output is ON)
Green LED
("RUN" mode: Lights up under stable light received condition or stable dark condition
"SET" mode: At the time of sensitivity setting, blinks twice when the difference between ON and OFF levels is greater than the hysteresis, but blinks 15 times when it is equal to or less than the hysteresis. Also blinks twice after the interference prevention is set
"SET" mode → When "SIF" or "RUN" mode is selected: Blinks from 0 to 5 times according to the sensitivity margin)
-
-
-
-
Shifts the set sensitivity level
Incorporated
ON-delay / OFF-delay timer (variable 0 to 5 sec.)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Cable lock lever: PPS
0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 65 g approx.
MS-DIN-2 (Amplifier mounting bracket): 1 pc., SU-CT1 (Stripper): 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
SH series
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
35 mA or less

NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between sensing output and 0 V)
・Residual voltage: 1.0 V or less (at 100 mA sink current)
        0.4 V or less (at 16 mA sink current)
Selectable either Light-ON or Dark-ON with the ON and OFF buttons
Incorporated

NPN open-collector transistor
・Maximum sink current: 50 mA
・Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
・Residual voltage: 1.0 V or less (at 50 mA sink current)
        0.4 V or less (at 16 mA sink current)
ON under unstable sensing condition (restored automatically after 40 ms approx.), or if the sensing output is short-circuited (restored when short-circuit is rectified).
(For the remote sensitivity adjustment type, it turns ON for 40 ms approx. Also after the remote sensitivity input is received.)
-
0.6 ms or less (0.8 ms or less when the interference prevention function is used)
Red LED (lights up when the sensing output is ON)
Green LED
("RUN" mode: Lights up under stable light received condition or stable dark condition
"SET" mode: At the time of sensitivity setting, blinks twice when the difference between ON and OFF levels is greater than the hysteresis, but blinks 15 times when it is equal to or less than the hysteresis. Also blinks twice after the interference prevention is set
"SET" mode → When "SIF" or "RUN" mode is selected: Blinks from 0 to 5 times according to the sensitivity margin)
Incorporated
Incorporated (Either gate or edge trigger is selectable)
-
-
Shifts the set sensitivity level
Incorporated
-
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +70 ℃ -4 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Cable lock lever: PPS
0.15 mm2 6-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 65 g approx.
MS-DIN-2 (Amplifier mounting bracket): 1 pc., SU-CT1 (Stripper): 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.