Specification

Specifications table for model SF4B-A28-01(V2)
ItemPerformance characteristics
CE Marking Directive ComplianceMachinery Directive, EMC Directive, RoHS Directive
No. of Beam Channels28
Protective Height 1,110 mm 43.701 in(Note:In the case of "When used as safety device for presses in China", the distance between the center of the first beam axis and the center of the last beam axis of the device becomes the protective height. For details, refer to "Definition of sensing heights".)
Protective Height: China Press Compliant (GB/T 4584)1,080mm 42.520 in
Current ConsumptionEmitter: 80 mA or less
Receiver: 120 mA or less
PFH<sub>D</sub>2.6 × 10-9
MTTF<sub>D</sub>100 years or more
Weight (Total Of Emitter And Receiver)2,170 g approx.
Applicable Standards: International StandardIEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
Applicable Standards: JapanJIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
(Note) PLe SIL3 compliant from production in August 2009.
Applicable Standards: Europe (EU)EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2
(Note) PLe SIL3 compliant from production in August 2009.
Applicable Standards: North AmericaANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06
(Note) PLe SIL3 compliant from production in August 2009.
Applicable Standards: China (GB)GB/T 4584
(Note) PLe SIL3 compliant from production in August 2009.
Operating Range0.3 to 9 m 0.984 to 29.528 ft
(Note) The operating range is the possible setting distance between the emitter and the receiver.
Min. Sensing Objectø45 mm ø1.772 in opaque object
(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
Effective Aperture Angleplus or minus 2.5°or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)]
Power Voltage 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Control Outputs (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 200 mA, When selecting NPN output: Max. sink current 200 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the control output and +V, When selecting NPN output: between the control output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 200 mA, when selecting NPN output: sink current 200 mA) (when using 20 m 65.617 ft length cable)
Control Outputs (OSSD 1, OSSD 2): Operation ModeON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.
(Note) In case the blanking function is valid, the operation mode is changed.
Control Outputs (OSSD1, OSSD2): Protection CircuitIncorporated
Response TimeOFF response: 14 ms or less, ON response: 80 to 90 ms
Auxiliary Output (Non-Safety Output)PNP open-collector transistor / NPN open-collector transistor (switching method)
- When selecting PNP output: Max. source current 60 mA, When selecting NPN output: Max. sink current 60 mA
- Applied voltage: same as supply voltage (When selecting PNP output: between the auxiliary output and +V, When selecting NPN output: between the auxiliary output and 0 V)
- Residual voltage: 2.5V or less (When selecting PNP output: source current 60 mA, when selecting NPN output: sink current 60 mA) (when using 20 m 65.617 ft length cable)
Auxiliary Output (Non-Safety Output): Operation ModeOFF when control outputs are ON, ON when control outputs are OFF (Factory setting; operating mode can be changed using the SFB-HC handy-controller(optional)).
Auxiliary Output (Non-Safety Output): Protection CircuitIncorporated
Interference Prevention FunctionIncorporated
(Note) Please use 12-core cable.
Auxiliary Output (Non-Safety Output): Response TimeOFF replay: 34 ms or less, ON replay 110 ms or less
Emission Halt FunctionIncorporated
Interlock FunctionIncorporated [Manual reset / Auto reset (Note)]
(Note) The manual reset and auto reset are possible to be switched depending on the wiring status.
External Device Monitoring FunctionIncorporated
Override FunctionIncorporated
(Note) Please use 12-core cable.
Muting Function Incorporated
(Note) Please use 12-core cable.
Environmental Resistance: Degree of ProtectionIP67 / IP65 (IEC)
Ambient Temperature-10 to +55 °+14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 °-13 to +158 ℉
Environmental Resistance: Dielectric Strength Voltage1,000 V AC for one min. between all supply terminals connected together and enclosure
Ambient Humidity30 to 85 % RH, Storage: 30 to 95 % RH
Ambient IlluminanceIncandescent light: 3,500 lx or less at the light-receiving face
Vibration Resistance10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Insulation Resistance20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Shock Resistance300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Emitting ElementInfrared LED (Peak emission wavelength: 870 nm 0.034 mil)
MaterialEnclosure: Aluminium
Upper and lower edges: Iron
Sensing surface: Polycarbonate / Polyester resin
Cap: PBT
Connecting MethodConnector
Cable LengthTotal length up to 50 m 164.042 ft is possible for both emitter and receiver, with optional mating cables
(Note) The cable can be extended within 30 m 98.425 ft (for emitter / receiver) when two light curtains are connected in series, within 20 m 65.617 ft when three light curtains are connected in series. Furthermore, when the muting lamp is used, the cable can be extended within 40 m 131.234 ft (for emitter / receiver).
AccessoriesMS-SFB-2 (Intermediate supporting bracket): 1 set
Applicable Standards: ChinaGB/T 4584
(Note) PLe SIL3 compliant from production in August 2009.