| | EMC Directive, RoHS Directive | 1 m 3.281 ft | Approx. 6 × 4 mm 0.236 × 0.157 in (vertical × horizontal) (at a sensing distance of 1 m) | Opaque object of ø2 mm ø0.079 in or more | Opaque object of ø0.3 mm ø0.012 in (Note)Typical values when the sensitivity adjuster is optimally adjusted. | | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | 0.01 mm 0.0004 in or less (all area) (Note)Typical values when the sensitivity adjuster is optimally adjusted. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 10 mA or less Receiver: 10 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 26.4 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) | Green LED (lights up when the power is ON) (incorporated on the emitter) | | Continuously variable adjuster (incorporated on the receiver) | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | 0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable (thru-beam type: Total 100 m 328.084 ft both emitter and receiver). | Net weight: Emitter: 40 g approx., Receiver: 40 g approx., Gross weight: 90 g approx. | MS-EXL2-2 (Mounting plate): 2 pcs. |
| | EMC Directive, RoHS Directive | 1 m 3.281 ft | Approx. 6 × 4 mm 0.236 × 0.157 in (vertical × horizontal) (at a sensing distance of 1 m) | Opaque object of ø2 mm ø0.079 in or more | Opaque object of ø0.3 mm ø0.012 in (Note)Typical values when the sensitivity adjuster is optimally adjusted. | | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | 0.01 mm 0.0004 in or less (all area) (Note)Typical values when the sensitivity adjuster is optimally adjusted. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 10 mA or less Receiver: 10 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 26.4 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) | Green LED (lights up when the power is ON) (incorporated on the emitter) | | Continuously variable adjuster (incorporated on the receiver) | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | 0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable (thru-beam type: Total 100 m 328.084 ft both emitter and receiver). | Net weight: Emitter: 40 g approx., Receiver: 40 g approx., Gross weight: 90 g approx. | MS-EXL2-2 (Mounting plate): 2 pcs. |
| | EMC Directive, RoHS Directive | 1 m 3.281 ft | Approx. 6 × 4 mm 0.236 × 0.157 in (vertical × horizontal) (at a sensing distance of 1 m) | Opaque object of ø2 mm ø0.079 in or more | Opaque object of ø0.3 mm ø0.012 in (Note)Typical values when the sensitivity adjuster is optimally adjusted. | | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | 0.01 mm 0.0004 in or less (all area) (Note)Typical values when the sensitivity adjuster is optimally adjusted. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 10 mA or less Receiver: 10 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 26.4 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) | Green LED (lights up when the power is ON) (incorporated on the emitter) | | Continuously variable adjuster (incorporated on the receiver) | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | | | | MS-EXL2-2 (Mounting plate): 2 pcs. |
| | EMC Directive, RoHS Directive | 3 m 9.843 ft | Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal) (at a sensing distance of 1 m) (Note) In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value). | Opaque object of ø3 mm ø0.118 in or more | - | | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | - | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 10 mA or less Receiver: 10 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 26.4 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) | - | | - | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | 0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long | | Net weight: Emitter: 40 g approx., Receiver: 40 g approx., Gross weight: 90 g approx. | MS-EXL2-2 (Mounting plate): 2 pcs. |
| | EMC Directive, RoHS Directive | 45 to 300 mm 1.772 to 11.811 in (Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object. | ø1 mm ø0.039 in or less (at a sensing distance of 300 mm) | ø1 mm ø0.039 in or less (at a sensing distance of 300 mm) | Gold wire of ø0.01 mm ø0.0004 in (Note)Typical values when the sensitivity adjuster is optimally adjusted. | 20 % or less of operation distance | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | 0.02 mm 0.0008 in or less (at 100 to 200 mm sensing distance) (Note)Typical values when the sensitivity adjuster is optimally adjusted. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 26.4 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | | | | Incorporated (Two sensors can be mounted close together.) | Continuously variable adjuster | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 2 mW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | 0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 45 g approx Gross weight: 60 g approx | MS-EXL2-3 (Mounting plate): 1 pc. |
| | EMC Directive, RoHS Directive | 3 m 9.843 ft | Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal) (at a sensing distance of 1 m) (Note) In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value). | Opaque object of ø3 mm ø0.118 in or more | - | | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | - | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 10 mA or less Receiver: 10 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 26.4 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) | - | | - | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | 0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long | | Net weight: Emitter: 40 g approx., Receiver: 40 g approx., Gross weight: 90 g approx. | MS-EXL2-2 (Mounting plate): 2 pcs. |
| | EMC Directive, RoHS Directive | 3 m 9.843 ft | Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal) (at a sensing distance of 1 m) (Note) In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value). | Opaque object of ø3 mm ø0.118 in or more | - | | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | - | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 10 mA or less Receiver: 10 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 26.4 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) | - | | - | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | | | | MS-EXL2-2 (Mounting plate): 2 pcs. |
| | EMC Directive, RoHS Directive | 3 m 9.843 ft | Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal) (at a sensing distance of 1 m) (Note) In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value). | Opaque object of ø3 mm ø0.118 in or more | - | | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | - | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 10 mA or less Receiver: 10 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 26.4 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type) | Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type) | - | | - | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | | | | MS-EXL2-2 (Mounting plate): 2 pcs. |
| | EMC Directive, RoHS Directive | 45 to 300 mm 1.772 to 11.811 in (Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object. | ø1 mm ø0.039 in or less (at a sensing distance of 300 mm) | ø1 mm ø0.039 in or less (at a sensing distance of 300 mm) | Gold wire of ø0.01 mm ø0.0004 in (Note)Typical values when the sensitivity adjuster is optimally adjusted. | 20 % or less of operation distance | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less | 0.02 mm 0.0008 in or less (at 100 to 200 mm sensing distance) (Note)Typical values when the sensitivity adjuster is optimally adjusted. | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 26.4 V DC or less (between output and +V) - Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | | | | Incorporated (Two sensors can be mounted close together.) | Continuously variable adjuster | IP67 (IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 2 mW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | | | | MS-EXL2-3 (Mounting plate): 1 pc. |
| | EMC Directive, RoHS Directive | 20 to 50 mm 0.787 to 1.969 in
(Convergent point: 22 mm 0.866 in) (Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object. | ø1mm 0.039 in or less (at a sensing distance of 50 mm) | Opaque, translucent or transparent object (Note)Make sure to confirm detection with an actual sensor before use. | Gold wire of ø0.01 mm ø0.0004 in (Note) Typical values when the sensitivity adjuster is optimally adjusted. | 20 % or less of operation distance | Perpendicular to sensing axis: 0.2 mm 0.0080 in or less | | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 50 mA | Light-ON / Dark-ON selectable by the output operation switching input | Incorporated (short-circuit protection / inverse polarity protection) | 0.5 ms or less | | | | | Continuously variable adjuster | IP67(IEC) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉ | 35 to 85%RH , Storage: 35 to 85%RH | | | | | | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).) (Maximum output: 1 mW, Peak emission wavelength: 655 nm 0.026 mil) | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate | 0.15 mm2 4-core cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable | | MS-EXL2-3 (Mounting plate): 1 pc. |