WH Series Built-In Web Server Programmable Displays

The WH Series of web-enabled panels provide users with advanced control and remote monitoring capabilities from any browser and device (smartphone, tablet, or computer), making them a perfect choice for demanding IIoT applications.  

FEATURES & BENEFITS:

  • Large, High-Resolution Screens With A Wide Color Range 
  • Connect To Various Networks And Protocols 
  • Remote Visualization And User Access 
  • Standard Model WHS – The Economical Screen 
  • Advanced Model WHA - The High-End Screen 

 

PLC & HMI Solution

FP0H Series AC Servo Motors

The Powerful And Compact FP0H Series PLC Caters To A Wide Variety Of Industrial Applications And Features Built-In Ethernet Ports To Enhance Networking And Connectivity

WH Series Content Band 1_628x354

Large, High-Resolution Screens With A Wide Color Range

The WH Series panels feature a clear, dynamic, high-resolution screen capable of displaying up to 16.7 million colors (advanced model only) with support for SVG vector graphics and object properties via Javascript.
 

WH-Series-content-band-2_628x354

Connect To Various Networks And Protocols

With support for over 50 common industrial protocols, the WH Series panels can be easily integrated into multi-vendor systems and can serve as a gateway to connect lower-level control systems to higher-level information systems without programming.
 

WH-Series-content-band-3_628x354

Remote Visualization And User Access

The WH Series' built-in HTML5 webserver and VNC support allow operators to remotely monitor their equipment in real-time from an office PC or smartphone/tablet.
 

WH Series Content Band 4_628x354

Standard Model WHS and Advanced Model WHA

The WHS standard models come with mid-sized, widescreen resistive touch panels and a simple interface for users with focused application requirements.  

The WHA advanced models come with large, glass capacitive touch panels that have excellent environmental resistances and support for gesture control.  Features an enhanced interface with multiple Ethernet ports, USB ports, and an SD card port.
 

Part Number List

Results 8
Models table for series WH Series Built-In Web Server Programmable Displays
Part No.DatasheetCE Marking Directive ComplianceRated VoltageOperating Voltage Range Current consumption (at 24 V DC)Ambient TemperatureAmbient Humidity Vibration ResistanceShock ResistanceProtectionPollution Degree Net Weight Displayable fontsNumber of registerable screens (pages)Registerable screen numberTypes of widgetMain FunctionsThrough functionDisplay : Display unitDisplay : ResolutionDisplay : ColorsDisplay : BacklightDisplay : Backlight brightness (Initial)Display : DimmingDisplay : Backlight life timeTouch switch : Touch switchTouch switch : Touch switch operatingTouch switch : Life timeMemory space : RAMMemory space : Flash memoryMemory space : Project memoryMemory space : User memoryRTC/Backup : Clock functionRTC/Backup : Accuracy RTCRTC/Backup : Backup rangeRTC/Backup : Backup function / periodOtherNumber of Communication PortsBaud RateConnecter shapeCable total lengthCommunication CableBer Of Simultaneous ConnectionsdlDNSDHCPFTP server/ClientHTTP server / clientSNTPCommunication standardConditions for communication with external devices : Baud rateConditions for communication with external devices : Data bitsConditions for communication with external devices : ParityConditions for communication with external devices : Stop bitTransmission distance (Total length)Terminal resistanceConnectorNumber of portsElectrical specificationsConnector shapeTransmission Speed Maximum currentSupport Mediaupported format standardDummy
EMC Directive, RoHS Directive, UL/c-UL Listing certification, Korea Radio Wave Regulations (Radio Wave Act KC)
24V DC
10 to 32 V DC
Note : The voltage tolerance range for maintaining a 10 ms voltage dips is limited to 20.4 to 32 V DC. * Does not include connection of external devices.
1.2 A or less
-20 to +50 ℃ -4 to +122 ℉ (Note),
Storage -20 to +70 ℃ -4 to +158 ℉
Note : In vertical installation conditions
5 to 85% RH (at +25 ℃ +77 ℉, No condensation or icing allowed, Same when storing)
5 to 9 Hz, 3.5 mm 0.138 in single amplitude, 9 to 150 Hz, Acceleration 9.8 m/s2 (1 G)
490 m/s2 (50 G), 11 ms, 3 times in the X, Y, Z directions
Front panel: IP66 (Initial value) (Note), Rear: IP20
Note : The IP66 is guaranteed only if:
・Max deviation from the plane surface to the cut-out: ≤ 0.5 mm 0.020 in
・Thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm 0.059 in to 0.236 in
・Max surface roughness where the gasket is applied: ≤ 120 μm
Also, tightening torque: 0.75 N•m (for advanced type: 1.3 N•m) or screw each fixing screw until the bezel corner gets in contact with the panel.
2
4.1 kg approx.
Fixed font, True Type font, Fonts installed in Windows®
Note : Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Note : A license (permission to use) is required to add the font.
Max. 1,000
Note : Maximum allowable number varies depending on registered contents.
Pages: 1,000
Dialog: 50
Template: 50
Basic (text, numerics), Button, Meter, Switch, Light, Media, Icon, Custom, etc.
Trends, Reports, Alarms, Scheduler, Database, Data transfers, Recipe, Keypads, Web Server, etc.
If a PC is connected to the LAN port of a WH series and a PLC is connected into the serial port, the PLC program can be debugged without a direct connection between the computer and the PLC.
Note : The only supported PLC is our FP series.
15.6 inch wide TFT
Note : On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions.
Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.
1,366×768, HD
16,770,000 colors
White LED
400 cd/m2(typ.)
Yes (Can be adjusted on the menu screen, xAscender Studio settings.
*There are some minor variations in the backlight brightness.
40,000 hours or more
Note : Time of continuous operation until the brightness of the backlight reaches 50% of the rated value when the surrounding air temperature is +25 ℃ +77 ℉
Capacitive type
-
-
2 GB
8 GB
240 MB
512 MB
Yes
±100 ppm or less (at +25 ℃ +77 ℉)
Note : At +25 ℃ +77 ℉: less than 260 seconds per month. On systems prone to clock error, set the correct time on a regular basis.
Clock back up
3 months with lithium batteries (secondary batteries)
(at +25 ℃ +77 ℉)
Note : Must be charged for 48 hours. When the battery is fully charged, it ensures a period of 48 hours of data backup.
Buzzer
1 port *Can be switched with xAscender Studio
100 Mbps / 10 Mbps, Auto negotiation
Note : Switching between different speeds is done automatically by auto negotiation function.
RJ-45
Note : Be careful not to apply excessive static electricity to the metal parts of the connector.
100 m 328.084 ft (500 m 1,640.42 ft when using a repeater)
Note : The maximum length of the cable is 100 m 328.084 ft in accordance with the standards, but depending on the operating environment, a ferrite core may be installed to reduce noise. May be required. It is also recommended that the hub be installed near the control panel and that it be used at 10 m 32.808 ft or less.
UTP cable (Category 5 or higher)
Max. 4
Full-duplex / Half-duplex
TCP/IP, UDP/IP
Name server support
Correspondence of automatic IP address acquisition
Server function: Transfer file / Client function: Transfer data and file
Server function: Customer web / Client function: Web browser
Correspondence of time setting function
Conforms to RS-232C (Non insulation type)
Conforms to RS-422 / RS-485 (Non insulation type)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s
Note : Communication conditions depend on the communications state of PLCs or other slave devices. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
7 bits / 8 bits
none / even / odd
1 bit / 2 bit
RS-232C : Max. 15 m 49.213 ft(Baud rate: 19,200 bps)
RS-422 / RS-485 : Max. 500 m 1,640.42 ft (Baud rate: 115.2 kbps)
RS-232C : -
RS-422 / RS-485 : No termination
Note : When connected to the termination, it is recommended that a 120Ω, 1/2W or better termination resistor be connected between the communication lines.
Connector supplied with advanced model
2 ports
Complies with USB 2.0
USB Type A
Note : Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector.
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
480 Mbps (High speed mode)
Max. 500 mA
SD memory card, SDHC memory card
Note : Industrial or business use SD memory cards (SLC type) are recommended. Check the operating temperature range of the SD memory card before use.
Conforms to SD standard (Note)
(Please format with a format software for SD memory cards.)
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
345.5 × 195 mm
13.602 × 7.677 in
EMC Directive, RoHS Directive, UL/c-UL Listing certification, Korea Radio Wave Regulations (Radio Wave Act KC)
24V DC
10 to 32 V DC
Note : The voltage tolerance range for maintaining a 10 ms voltage dips is limited to 20.4 to 32 V DC. * Does not include connection of external devices.
0.7 A or less
-20 to +50 ℃ -4 to +122 ℉ (Note),
Storage -20 to +70 ℃ -4 to +158 ℉
Note : In vertical installation conditions
5 to 85% RH (at +25 ℃ +77 ℉, No condensation or icing allowed, Same when storing)
5 to 9 Hz, 3.5 mm 0.138 in single amplitude, 9 to 150 Hz, Acceleration 9.8 m/s2 (1 G)
490 m/s2 (50 G), 11 ms, 3 times in the X, Y, Z directions
Front panel: IP66 (Initial value) (Note), Rear: IP20
Note : The IP66 is guaranteed only if:
・Max deviation from the plane surface to the cut-out: ≤ 0.5 mm 0.020 in
・Thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm 0.059 in to 0.236 in
・Max surface roughness where the gasket is applied: ≤ 120 μm
Also, tightening torque: 0.75 N•m (for advanced type: 1.3 N•m) or screw each fixing screw until the bezel corner gets in contact with the panel.
2
1.3 kg approx.
Fixed font, True Type font, Fonts installed in Windows®
Note : Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Note : A license (permission to use) is required to add the font.
Max. 1,000
Note : Maximum allowable number varies depending on registered contents.
Pages: 1,000
Dialog: 50
Template: 50
Basic (text, numerics), Button, Meter, Switch, Light, Media, Icon, Custom, etc.
Trends, Reports, Alarms, Scheduler, Database, Data transfers, Recipe, Keypads, Web Server, etc.
If a PC is connected to the LAN port of a WH series and a PLC is connected into the serial port, the PLC program can be debugged without a direct connection between the computer and the PLC.
Note : The only supported PLC is our FP series.
7 inch wide TFT
Note : On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions.
Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.
800×480, WVGA
16,770,000 colors
White LED
500 cd/m2(typ.)
Yes (Can be adjusted on the menu screen, xAscender Studio settings.
*There are some minor variations in the backlight brightness.
40,000 hours or more
Note : Time of continuous operation until the brightness of the backlight reaches 50% of the rated value when the surrounding air temperature is +25 ℃ +77 ℉
Capacitive type
-
-
1 GB
4 GB
240 MB
512 MB
Yes
±100 ppm or less (at +25 ℃ +77 ℉)
Note : At +25 ℃ +77 ℉: less than 260 seconds per month. On systems prone to clock error, set the correct time on a regular basis.
Clock back up
3 months with lithium batteries (secondary batteries)
(at +25 ℃ +77 ℉)
Note : Must be charged for 48 hours. When the battery is fully charged, it ensures a period of 48 hours of data backup.
Buzzer
1 port *Can be switched with xAscender Studio
100 Mbps / 10 Mbps, Auto negotiation
Note : Switching between different speeds is done automatically by auto negotiation function.
RJ-45
Note : Be careful not to apply excessive static electricity to the metal parts of the connector.
100 m 328.084 ft (500 m 1,640.42 ft when using a repeater)
Note : The maximum length of the cable is 100 m 328.084 ft in accordance with the standards, but depending on the operating environment, a ferrite core may be installed to reduce noise. May be required. It is also recommended that the hub be installed near the control panel and that it be used at 10 m 32.808 ft or less.
UTP cable (Category 5 or higher)
Max. 4
Full-duplex / Half-duplex
TCP/IP, UDP/IP
Name server support
Correspondence of automatic IP address acquisition
Server function: Transfer file / Client function: Transfer data and file
Server function: Customer web / Client function: Web browser
Correspondence of time setting function
Conforms to RS-232C (Non insulation type)
Conforms to RS-422 / RS-485 (Non insulation type)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s
Note : Communication conditions depend on the communications state of PLCs or other slave devices. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
7 bits / 8 bits
none / even / odd
1 bit / 2 bit
RS-232C : Max. 15 m 49.213 ft(Baud rate: 19,200 bps)
RS-422 / RS-485 : Max. 500 m 1,640.42 ft (Baud rate: 115.2 kbps)
RS-232C : -
RS-422 / RS-485 : No termination
Note : When connected to the termination, it is recommended that a 120Ω, 1/2W or better termination resistor be connected between the communication lines.
Connector supplied with advanced model
2 ports
Complies with USB 2.0
USB Type A
Note : Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector.
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
480 Mbps (High speed mode)
Max. 500 mA
SD memory card, SDHC memory card
Note : Industrial or business use SD memory cards (SLC type) are recommended. Check the operating temperature range of the SD memory card before use.
Conforms to SD standard (Note)
(Please format with a format software for SD memory cards.)
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
152.6 × 91.6 mm
6.008 × 3.606 in
EMC Directive, RoHS Directive, UL/c-UL Listing certification, Korea Radio Wave Regulations (Radio Wave Act KC)
24V DC
10 to 32 V DC
0.3 A or less
0 to +50 ℃ +32 to +122 ℉ (Note),
Storage -20 to +70 ℃ -4 to +158 ℉
Note : In vertical installation conditions
5 to 85% RH (at +25 ℃ +77 ℉, No condensation or icing allowed, Same when storing)
5 to 9 Hz, 3.5 mm 0.138 in single amplitude, 9 to 150 Hz, Acceleration 9.8 m/s2 (1 G)
490 m/s2 (50 G), 11 ms, 3 times in the X, Y, Z directions
Front panel: IP66 (Initial value) (Note), Rear: IP20
Note : The IP66 is guaranteed only if:
・Max deviation from the plane surface to the cut-out: ≤ 0.5 mm 0.020 in
・Thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm 0.059 in to 0.236 in
・Max surface roughness where the gasket is applied: ≤ 120 μm
Also, tightening torque: 0.75 N•m (for advanced type: 1.3 N•m) or screw each fixing screw until the bezel corner gets in contact with the panel.
2
0.6 kg approx.
Fixed font, True Type font, Fonts installed in Windows®
Note : Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Note : A license (permission to use) is required to add the font.
Max. 1,000
Note : Maximum allowable number varies depending on registered contents.
Pages: 1,000
Dialog: 50
Template: 50
Basic (text, numerics), Button, Meter, Switch, Light, Media, Icon, Custom, etc.
Trends, Reports, Alarms, Scheduler, Database, Data transfers, Recipe, Keypads, Web Server, etc.
If a PC is connected to the LAN port of a WH series and a PLC is connected into the serial port, the PLC program can be debugged without a direct connection between the computer and the PLC.
Note : The only supported PLC is our FP series.
7 inch wide TFT
Note : On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions.
Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.
800×480, WVGA
65,536 colors
White LED
200 cd/m2(typ.)
Yes (Can be adjusted on the menu screen, xAscender Studio settings.
*There are some minor variations in the backlight brightness.
20,000 hours or more
Note : Time of continuous operation until the brightness of the backlight reaches 50% of the rated value when the surrounding air temperature is +25 ℃ +77 ℉
Analog resistive film type
1.5 N or less
1 million times or more
Note : The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.
512 MB
4 GB
240 MB
512 MB
Yes
±100 ppm or less (at +25 ℃ +77 ℉)
Note : At +25 ℃ +77 ℉: less than 260 seconds per month. On systems prone to clock error, set the correct time on a regular basis.
Clock back up
48h with super capacitor backup
(at +25 ℃ +77 ℉)
Note : Must be charged for 48 hours. When the battery is fully charged, it ensures a period of 48 hours of data backup.
Buzzer
1 port *Can be switched with xAscender Studio
100 Mbps / 10 Mbps, Auto negotiation
Note : Switching between different speeds is done automatically by auto negotiation function.
RJ-45
Note : Be careful not to apply excessive static electricity to the metal parts of the connector.
100 m 328.084 ft (500 m 1,640.42 ft when using a repeater)
Note : The maximum length of the cable is 100 m 328.084 ft in accordance with the standards, but depending on the operating environment, a ferrite core may be installed to reduce noise. May be required. It is also recommended that the hub be installed near the control panel and that it be used at 10 m 32.808 ft or less.
UTP cable (Category 5 or higher)
Max. 4
Full-duplex / Half-duplex
TCP/IP, UDP/IP
Name server support
Correspondence of automatic IP address acquisition
Server function: Transfer file / Client function: Transfer data and file
Server function: Customer web / Client function: Web browser
Correspondence of time setting function
Conforms to RS-232C (Non insulation type)
Conforms to RS-422 / RS-485 (Non insulation type)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s
Note : Communication conditions depend on the communications state of PLCs or other slave devices. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
7 bits / 8 bits
none / even / odd
1 bit / 2 bit
RS-232C : Max. 15 m 49.213 ft(Baud rate: 19,200 bps)
RS-422 / RS-485 : Max. 500 m 1,640.42 ft (Baud rate: 115.2 kbps)
RS-232C : -
RS-422 / RS-485 : No termination
Note : When connected to the termination, it is recommended that a 120Ω, 1/2W or better termination resistor be connected between the communication lines.
D-Sub 9 pins
Note : Use standard commercially available 9-pin D-sub male connector.
1 port
Complies with USB 2.0
USB Type A
Note : Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector.
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
480 Mbps (High speed mode)
Max. 500 mA
155.5 × 88 mm
6.122× 3.465 in
EMC Directive, RoHS Directive, UL/c-UL Listing certification, Korea Radio Wave Regulations (Radio Wave Act KC)
24V DC
10 to 32 V DC
0.25 A or less
0 to +50 ℃ +32 to +122 ℉ (Note),
Storage -20 to +70 ℃ -4 to +158 ℉
Note : In vertical installation conditions
5 to 85% RH (at +25 ℃ +77 ℉, No condensation or icing allowed, Same when storing)
5 to 9 Hz, 3.5 mm 0.138 in single amplitude, 9 to 150 Hz, Acceleration 9.8 m/s2 (1 G)
490 m/s2 (50 G), 11 ms, 3 times in the X, Y, Z directions
Front panel: IP66 (Initial value) (Note), Rear: IP20
Note : The IP66 is guaranteed only if:
・Max deviation from the plane surface to the cut-out: ≤ 0.5 mm 0.020 in
・Thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm 0.059 in to 0.236 in
・Max surface roughness where the gasket is applied: ≤ 120 μm
Also, tightening torque: 0.75 N•m (for advanced type: 1.3 N•m) or screw each fixing screw until the bezel corner gets in contact with the panel.
2
0.4 kg approx.
Fixed font, True Type font, Fonts installed in Windows®
Note : Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Note : A license (permission to use) is required to add the font.
Max. 1,000
Note : Maximum allowable number varies depending on registered contents.
Pages: 1,000
Dialog: 50
Template: 50
Basic (text, numerics), Button, Meter, Switch, Light, Media, Icon, Custom, etc.
Trends, Reports, Alarms, Scheduler, Database, Data transfers, Recipe, Keypads, Web Server, etc.
If a PC is connected to the LAN port of a WH series and a PLC is connected into the serial port, the PLC program can be debugged without a direct connection between the computer and the PLC.
Note : The only supported PLC is our FP series.
4.3 inch wide TFT
Note : On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions.
Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.
480×272, WQVGA
65,536 colors
White LED
200 cd/m2(typ.)
Yes (Can be adjusted on the menu screen, xAscender Studio settings.
*There are some minor variations in the backlight brightness.
20,000 hours or more
Note : Time of continuous operation until the brightness of the backlight reaches 50% of the rated value when the surrounding air temperature is +25 ℃ +77 ℉
Analog resistive film type
1.5 N or less
1 million times or more
Note : The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.
512 MB
4 GB
240 MB
512 MB
Yes
±100 ppm or less (at +25 ℃ +77 ℉)
Note : At +25 ℃ +77 ℉: less than 260 seconds per month. On systems prone to clock error, set the correct time on a regular basis.
Clock back up
48h with super capacitor backup
(at +25 ℃ +77 ℉)
Note : Must be charged for 48 hours. When the battery is fully charged, it ensures a period of 48 hours of data backup.
Buzzer
1 port *Can be switched with xAscender Studio
100 Mbps / 10 Mbps, Auto negotiation
Note : Switching between different speeds is done automatically by auto negotiation function.
RJ-45
Note : Be careful not to apply excessive static electricity to the metal parts of the connector.
100 m 328.084 ft (500 m 1,640.42 ft when using a repeater)
Note : The maximum length of the cable is 100 m 328.084 ft in accordance with the standards, but depending on the operating environment, a ferrite core may be installed to reduce noise. May be required. It is also recommended that the hub be installed near the control panel and that it be used at 10 m 32.808 ft or less.
UTP cable (Category 5 or higher)
Max. 4
Full-duplex / Half-duplex
TCP/IP, UDP/IP
Name server support
Correspondence of automatic IP address acquisition
Server function: Transfer file / Client function: Transfer data and file
Server function: Customer web / Client function: Web browser
Correspondence of time setting function
Conforms to RS-232C (Non insulation type)
Conforms to RS-422 / RS-485 (Non insulation type)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s
Note : Communication conditions depend on the communications state of PLCs or other slave devices. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
7 bits / 8 bits
none / even / odd
1 bit / 2 bit
RS-232C : Max. 15 m 49.213 ft(Baud rate: 19,200 bps)
RS-422 / RS-485 : Max. 500 m 1,640.42 ft (Baud rate: 115.2 kbps)
RS-232C : -
RS-422 / RS-485 : No termination
Note : When connected to the termination, it is recommended that a 120Ω, 1/2W or better termination resistor be connected between the communication lines.
D-Sub 9 pins
Note : Use standard commercially available 9-pin D-sub male connector.
1 port
Complies with USB 2.0
USB Type A
Note : Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector.
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
480 Mbps (High speed mode)
Max. 500 mA
96.4 × 55.2 mm
3.795 × 2.173 in
EMC Directive, RoHS Directive, UL/c-UL Listing certification, Korea Radio Wave Regulations (Radio Wave Act KC)
24V DC
10 to 32 V DC
Note : The voltage tolerance range for maintaining a 10 ms voltage dips is limited to 20.4 to 32 V DC. * Does not include connection of external devices.
0.6 A or less
-20 to +50 ℃ -4 to +122 ℉ (Note),
Storage -20 to +70 ℃ -4 to +158 ℉
Note : In vertical installation conditions
5 to 85% RH (at +25 ℃ +77 ℉, No condensation or icing allowed, Same when storing)
5 to 9 Hz, 3.5 mm 0.138 in single amplitude, 9 to 150 Hz, Acceleration 9.8 m/s2 (1 G)
490 m/s2 (50 G), 11 ms, 3 times in the X, Y, Z directions
Front panel: IP66 (Initial value) (Note), Rear: IP20
Note : The IP66 is guaranteed only if:
・Max deviation from the plane surface to the cut-out: ≤ 0.5 mm 0.020 in
・Thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm 0.059 in to 0.236 in
・Max surface roughness where the gasket is applied: ≤ 120 μm
Also, tightening torque: 0.75 N•m (for advanced type: 1.3 N•m) or screw each fixing screw until the bezel corner gets in contact with the panel.
2
1 kg approx.
Fixed font, True Type font, Fonts installed in Windows®
Note : Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Note : A license (permission to use) is required to add the font.
Max. 1,000
Note : Maximum allowable number varies depending on registered contents.
Pages: 1,000
Dialog: 50
Template: 50
Basic (text, numerics), Button, Meter, Switch, Light, Media, Icon, Custom, etc.
Trends, Reports, Alarms, Scheduler, Database, Data transfers, Recipe, Keypads, Web Server, etc.
If a PC is connected to the LAN port of a WH series and a PLC is connected into the serial port, the PLC program can be debugged without a direct connection between the computer and the PLC.
Note : The only supported PLC is our FP series.
5 inch wide TFT
Note : On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions.
Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.
800×480, WVGA
65,536 colors
White LED
300 cd/m2(typ.)
Yes (Can be adjusted on the menu screen, xAscender Studio settings.
*There are some minor variations in the backlight brightness.
40,000 hours or more
Note : Time of continuous operation until the brightness of the backlight reaches 50% of the rated value when the surrounding air temperature is +25 ℃ +77 ℉
Capacitive type
-
-
512 MB
4 GB
240 MB
512 MB
Yes
±100 ppm or less (at +25 ℃ +77 ℉)
Note : At +25 ℃ +77 ℉: less than 260 seconds per month. On systems prone to clock error, set the correct time on a regular basis.
Clock back up
3 months with lithium batteries (secondary batteries)
(at +25 ℃ +77 ℉)
Note : Must be charged for 48 hours. When the battery is fully charged, it ensures a period of 48 hours of data backup.
Buzzer
1 port *Can be switched with xAscender Studio
100 Mbps / 10 Mbps, Auto negotiation
Note : Switching between different speeds is done automatically by auto negotiation function.
RJ-45
Note : Be careful not to apply excessive static electricity to the metal parts of the connector.
100 m 328.084 ft (500 m 1,640.42 ft when using a repeater)
Note : The maximum length of the cable is 100 m 328.084 ft in accordance with the standards, but depending on the operating environment, a ferrite core may be installed to reduce noise. May be required. It is also recommended that the hub be installed near the control panel and that it be used at 10 m 32.808 ft or less.
UTP cable (Category 5 or higher)
Max. 4
Full-duplex / Half-duplex
TCP/IP, UDP/IP
Name server support
Correspondence of automatic IP address acquisition
Server function: Transfer file / Client function: Transfer data and file
Server function: Customer web / Client function: Web browser
Correspondence of time setting function
Conforms to RS-232C (Non insulation type)
Conforms to RS-422 / RS-485 (Non insulation type)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s
Note : Communication conditions depend on the communications state of PLCs or other slave devices. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
7 bits / 8 bits
none / even / odd
1 bit / 2 bit
RS-232C : Max. 15 m 49.213 ft(Baud rate: 19,200 bps)
RS-422 / RS-485 : Max. 500 m 1,640.42 ft (Baud rate: 115.2 kbps)
RS-232C : -
RS-422 / RS-485 : No termination
Note : When connected to the termination, it is recommended that a 120Ω, 1/2W or better termination resistor be connected between the communication lines.
Connector supplied with advanced model
1 port
Complies with USB 2.0
USB Type A
Note : Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector.
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
480 Mbps (High speed mode)
Max. 500 mA
SD memory card, SDHC memory card
Note : Industrial or business use SD memory cards (SLC type) are recommended. Check the operating temperature range of the SD memory card before use.
Conforms to SD standard (Note)
(Please format with a format software for SD memory cards.)
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
109 × 65.8 mm
4.291 × 2.591 in
EMC Directive, RoHS Directive, UL/c-UL Listing certification, Korea Radio Wave Regulations (Radio Wave Act KC)
24V DC
10 to 32 V DC
Note : The voltage tolerance range for maintaining a 10 ms voltage dips is limited to 20.4 to 32 V DC. * Does not include connection of external devices.
1.7 A or less
-20 to +50 ℃ -4 to +122 ℉ (Note),
Storage -20 to +70 ℃ -4 to +158 ℉
Note : In vertical installation conditions
5 to 85% RH (at +25 ℃ +77 ℉, No condensation or icing allowed, Same when storing)
5 to 9 Hz, 3.5 mm 0.138 in single amplitude, 9 to 150 Hz, Acceleration 9.8 m/s2 (1 G)
490 m/s2 (50 G), 11 ms, 3 times in the X, Y, Z directions
Front panel: IP66 (Initial value) (Note), Rear: IP20
Note : The IP66 is guaranteed only if:
・Max deviation from the plane surface to the cut-out: ≤ 0.5 mm 0.020 in
・Thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm 0.059 in to 0.236 in
・Max surface roughness where the gasket is applied: ≤ 120 μm
Also, tightening torque: 0.75 N•m (for advanced type: 1.3 N•m) or screw each fixing screw until the bezel corner gets in contact with the panel.
2
6.1 kg approx.
Fixed font, True Type font, Fonts installed in Windows®
Note : Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Note : A license (permission to use) is required to add the font.
Max. 1,000
Note : Maximum allowable number varies depending on registered contents.
Pages: 1,000
Dialog: 50
Template: 50
Basic (text, numerics), Button, Meter, Switch, Light, Media, Icon, Custom, etc.
Trends, Reports, Alarms, Scheduler, Database, Data transfers, Recipe, Keypads, Web Server, etc.
If a PC is connected to the LAN port of a WH series and a PLC is connected into the serial port, the PLC program can be debugged without a direct connection between the computer and the PLC.
Note : The only supported PLC is our FP series.
21.5 inch wide TFT
Note : On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions.
Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.
1,920×1,080, Full HD
16,770,000 colors
White LED
300 cd/m2(typ.)
Yes (Can be adjusted on the menu screen, xAscender Studio settings.
*There are some minor variations in the backlight brightness.
40,000 hours or more
Note : Time of continuous operation until the brightness of the backlight reaches 50% of the rated value when the surrounding air temperature is +25 ℃ +77 ℉
Capacitive type
-
-
2 GB
8 GB
240 MB
512 MB
Yes
±100 ppm or less (at +25 ℃ +77 ℉)
Note : At +25 ℃ +77 ℉: less than 260 seconds per month. On systems prone to clock error, set the correct time on a regular basis.
Clock back up
3 months with lithium batteries (secondary batteries)
(at +25 ℃ +77 ℉)
Note : Must be charged for 48 hours. When the battery is fully charged, it ensures a period of 48 hours of data backup.
Buzzer
1 port *Can be switched with xAscender Studio
100 Mbps / 10 Mbps, Auto negotiation
Note : Switching between different speeds is done automatically by auto negotiation function.
RJ-45
Note : Be careful not to apply excessive static electricity to the metal parts of the connector.
100 m 328.084 ft (500 m 1,640.42 ft when using a repeater)
Note : The maximum length of the cable is 100 m 328.084 ft in accordance with the standards, but depending on the operating environment, a ferrite core may be installed to reduce noise. May be required. It is also recommended that the hub be installed near the control panel and that it be used at 10 m 32.808 ft or less.
UTP cable (Category 5 or higher)
Max. 4
Full-duplex / Half-duplex
TCP/IP, UDP/IP
Name server support
Correspondence of automatic IP address acquisition
Server function: Transfer file / Client function: Transfer data and file
Server function: Customer web / Client function: Web browser
Correspondence of time setting function
Conforms to RS-232C (Non insulation type)
Conforms to RS-422 / RS-485 (Non insulation type)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s
Note : Communication conditions depend on the communications state of PLCs or other slave devices. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
7 bits / 8 bits
none / even / odd
1 bit / 2 bit
RS-232C : Max. 15 m 49.213 ft(Baud rate: 19,200 bps)
RS-422 / RS-485 : Max. 500 m 1,640.42 ft (Baud rate: 115.2 kbps)
RS-232C : -
RS-422 / RS-485 : No termination
Note : When connected to the termination, it is recommended that a 120Ω, 1/2W or better termination resistor be connected between the communication lines.
Connector supplied with advanced model
2 ports
Complies with USB 2.0
USB Type A
Note : Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector.
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
480 Mbps (High speed mode)
Max. 500 mA
SD memory card, SDHC memory card
Note : Industrial or business use SD memory cards (SLC type) are recommended. Check the operating temperature range of the SD memory card before use.
Conforms to SD standard (Note)
(Please format with a format software for SD memory cards.)
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
478 × 269.5 mm
18.819 × 10.610 in
EMC Directive, RoHS Directive, UL/c-UL Listing certification, Korea Radio Wave Regulations (Radio Wave Act KC)
24V DC
10 to 32 V DC
Note : The voltage tolerance range for maintaining a 10 ms voltage dips is limited to 20.4 to 32 V DC. * Does not include connection of external devices.
1 A or less
-20 to +50 ℃ -4 to +122 ℉ (Note),
Storage -20 to +70 ℃ -4 to +158 ℉
Note : In vertical installation conditions
5 to 85% RH (at +25 ℃ +77 ℉, No condensation or icing allowed, Same when storing)
5 to 9 Hz, 3.5 mm 0.138 in single amplitude, 9 to 150 Hz, Acceleration 9.8 m/s2 (1 G)
490 m/s2 (50 G), 11 ms, 3 times in the X, Y, Z directions
Front panel: IP66 (Initial value) (Note), Rear: IP20
Note : The IP66 is guaranteed only if:
・Max deviation from the plane surface to the cut-out: ≤ 0.5 mm 0.020 in
・Thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm 0.059 in to 0.236 in
・Max surface roughness where the gasket is applied: ≤ 120 μm
Also, tightening torque: 0.75 N•m (for advanced type: 1.3 N•m) or screw each fixing screw until the bezel corner gets in contact with the panel.
2
2.5 kg approx.
Fixed font, True Type font, Fonts installed in Windows®
Note : Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Note : A license (permission to use) is required to add the font.
Max. 1,000
Note : Maximum allowable number varies depending on registered contents.
Pages: 1,000
Dialog: 50
Template: 50
Basic (text, numerics), Button, Meter, Switch, Light, Media, Icon, Custom, etc.
Trends, Reports, Alarms, Scheduler, Database, Data transfers, Recipe, Keypads, Web Server, etc.
If a PC is connected to the LAN port of a WH series and a PLC is connected into the serial port, the PLC program can be debugged without a direct connection between the computer and the PLC.
Note : The only supported PLC is our FP series.
10.1 inch wide TFT
Note : On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions.
Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.
1,280×800, WXGA
16,770,000 colors
White LED
500 cd/m2(typ.)
Yes (Can be adjusted on the menu screen, xAscender Studio settings.
*There are some minor variations in the backlight brightness.
40,000 hours or more
Note : Time of continuous operation until the brightness of the backlight reaches 50% of the rated value when the surrounding air temperature is +25 ℃ +77 ℉
Capacitive type
-
-
1 GB
4 GB
240 MB
512 MB
Yes
±100 ppm or less (at +25 ℃ +77 ℉)
Note : At +25 ℃ +77 ℉: less than 260 seconds per month. On systems prone to clock error, set the correct time on a regular basis.
Clock back up
3 months with lithium batteries (secondary batteries)
(at +25 ℃ +77 ℉)
Note : Must be charged for 48 hours. When the battery is fully charged, it ensures a period of 48 hours of data backup.
Buzzer
1 port *Can be switched with xAscender Studio
100 Mbps / 10 Mbps, Auto negotiation
Note : Switching between different speeds is done automatically by auto negotiation function.
RJ-45
Note : Be careful not to apply excessive static electricity to the metal parts of the connector.
100 m 328.084 ft (500 m 1,640.42 ft when using a repeater)
Note : The maximum length of the cable is 100 m 328.084 ft in accordance with the standards, but depending on the operating environment, a ferrite core may be installed to reduce noise. May be required. It is also recommended that the hub be installed near the control panel and that it be used at 10 m 32.808 ft or less.
UTP cable (Category 5 or higher)
Max. 4
Full-duplex / Half-duplex
TCP/IP, UDP/IP
Name server support
Correspondence of automatic IP address acquisition
Server function: Transfer file / Client function: Transfer data and file
Server function: Customer web / Client function: Web browser
Correspondence of time setting function
Conforms to RS-232C (Non insulation type)
Conforms to RS-422 / RS-485 (Non insulation type)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s
Note : Communication conditions depend on the communications state of PLCs or other slave devices. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
7 bits / 8 bits
none / even / odd
1 bit / 2 bit
RS-232C : Max. 15 m 49.213 ft(Baud rate: 19,200 bps)
RS-422 / RS-485 : Max. 500 m 1,640.42 ft (Baud rate: 115.2 kbps)
RS-232C : -
RS-422 / RS-485 : No termination
Note : When connected to the termination, it is recommended that a 120Ω, 1/2W or better termination resistor be connected between the communication lines.
Connector supplied with advanced model
2 ports
Complies with USB 2.0
USB Type A
Note : Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector.
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
480 Mbps (High speed mode)
Max. 500 mA
SD memory card, SDHC memory card
Note : Industrial or business use SD memory cards (SLC type) are recommended. Check the operating temperature range of the SD memory card before use.
Conforms to SD standard (Note)
(Please format with a format software for SD memory cards.)
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
217.9 × 136.6 mm
8.579 × 5.378 in
EMC Directive, RoHS Directive, UL/c-UL Listing certification, Korea Radio Wave Regulations (Radio Wave Act KC)
24V DC
10 to 32 V DC
0.38 A or less
0 to +50 ℃ +32 to +122 ℉ (Note),
Storage -20 to +70 ℃ -4 to +158 ℉
Note : In vertical installation conditions
5 to 85% RH (at +25 ℃ +77 ℉, No condensation or icing allowed, Same when storing)
5 to 9 Hz, 3.5 mm 0.138 in single amplitude, 9 to 150 Hz, Acceleration 9.8 m/s2 (1 G)
490 m/s2 (50 G), 11 ms, 3 times in the X, Y, Z directions
Front panel: IP66 (Initial value) (Note), Rear: IP20
Note : The IP66 is guaranteed only if:
・Max deviation from the plane surface to the cut-out: ≤ 0.5 mm 0.020 in
・Thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm 0.059 in to 0.236 in
・Max surface roughness where the gasket is applied: ≤ 120 μm
Also, tightening torque: 0.75 N•m (for advanced type: 1.3 N•m) or screw each fixing screw until the bezel corner gets in contact with the panel.
2
1 kg approx.
Fixed font, True Type font, Fonts installed in Windows®
Note : Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
Note : A license (permission to use) is required to add the font.
Max. 1,000
Note : Maximum allowable number varies depending on registered contents.
Pages: 1,000
Dialog: 50
Template: 50
Basic (text, numerics), Button, Meter, Switch, Light, Media, Icon, Custom, etc.
Trends, Reports, Alarms, Scheduler, Database, Data transfers, Recipe, Keypads, Web Server, etc.
If a PC is connected to the LAN port of a WH series and a PLC is connected into the serial port, the PLC program can be debugged without a direct connection between the computer and the PLC.
Note : The only supported PLC is our FP series.
10.1 inch wide TFT
Note : On the LCD panel, bright spots (points always lit) or black spots (points always unlit) may appear, or the uneven brightness, flickers or crosstalk (appearance of unintended shades in the area no graphic or part is arranged) may occur depending on the operating conditions.
Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product.
1,024×600 WSVGA
65,536 colors
White LED
200 cd/m2(typ.)
Yes (Can be adjusted on the menu screen, xAscender Studio settings.
*There are some minor variations in the backlight brightness.
20,000 hours or more
Note : Time of continuous operation until the brightness of the backlight reaches 50% of the rated value when the surrounding air temperature is +25 ℃ +77 ℉
Analog resistive film type
1.5 N or less
1 million times or more
Note : The touch position may shift due to aging variation. If the touch position has shifted greatly, please adjust it.
512 MB
4 GB
240 MB
512 MB
Yes
±100 ppm or less (at +25 ℃ +77 ℉)
Note : At +25 ℃ +77 ℉: less than 260 seconds per month. On systems prone to clock error, set the correct time on a regular basis.
Clock back up
48h with super capacitor backup
(at +25 ℃ +77 ℉)
Note : Must be charged for 48 hours. When the battery is fully charged, it ensures a period of 48 hours of data backup.
Buzzer
1 port *Can be switched with xAscender Studio
100 Mbps / 10 Mbps, Auto negotiation
Note : Switching between different speeds is done automatically by auto negotiation function.
RJ-45
Note : Be careful not to apply excessive static electricity to the metal parts of the connector.
100 m 328.084 ft (500 m 1,640.42 ft when using a repeater)
Note : The maximum length of the cable is 100 m 328.084 ft in accordance with the standards, but depending on the operating environment, a ferrite core may be installed to reduce noise. May be required. It is also recommended that the hub be installed near the control panel and that it be used at 10 m 32.808 ft or less.
UTP cable (Category 5 or higher)
Max. 4
Full-duplex / Half-duplex
TCP/IP, UDP/IP
Name server support
Correspondence of automatic IP address acquisition
Server function: Transfer file / Client function: Transfer data and file
Server function: Customer web / Client function: Web browser
Correspondence of time setting function
Conforms to RS-232C (Non insulation type)
Conforms to RS-422 / RS-485 (Non insulation type)
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bit/s
Note : Communication conditions depend on the communications state of PLCs or other slave devices. Please check with the actual devices when some commercial devices with RS485 interface are connected. The number of connected devices, transmission distance, and transmission speed may be different according to using transmission line.
7 bits / 8 bits
none / even / odd
1 bit / 2 bit
RS-232C : Max. 15 m 49.213 ft(Baud rate: 19,200 bps)
RS-422 / RS-485 : Max. 500 m 1,640.42 ft (Baud rate: 115.2 kbps)
RS-232C : -
RS-422 / RS-485 : No termination
Note : When connected to the termination, it is recommended that a 120Ω, 1/2W or better termination resistor be connected between the communication lines.
D-Sub 9 pins
Note : Use standard commercially available 9-pin D-sub male connector.
1 port
Complies with USB 2.0
USB Type A
Note : Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector.
Note : The format of the external memory should be in FAT32 or FAT. The max number of files inside external memory depends on the type of formatting.
• FAT32: Max. 65,535 files • FAT: Max. 512 files
480 Mbps (High speed mode)
Max. 500 mA
224.3 × 126.8 mm
8.831 × 4.992 in

What's New

Stay up to date