Part No.sort descendingData SheetCE marking directive compliancePower supplyOperating voltage rangePower consumptionPower supply unit isolation methodAmbient temperatureAmbient humidityStorage temperatureStorage humidityVibration resistanceParts Inventory
   Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Power supply

Column active Filter
Close

Filter by Operating voltage range

Column active Filter
Close

Filter by Power consumption

Column active Filter
Close

Filter by Power supply unit isolation method

Column active Filter
Close

Filter by Ambient temperature

Column active Filter
Close

Filter by Ambient humidity

Column active Filter
Close

Filter by Storage temperature

Column active Filter
Close

Filter by Storage humidity

Column active Filter
Close

Filter by Vibration resistance

 
design engineersPanasonicAIG02GQ15D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02GQ04D
EMC Directive, RoHS Directive5 V DC4.5 to 5.5 V DC1 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02GQ05D
EMC Directive, RoHS Directive5 V DC4.5 to 5.5 V DC1 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02GQ24D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02MQ05D
EMC Directive, RoHS Directive5 V DC4.5 to 5.5 V DC1 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02MQ12D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02MQ13D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02MQ14D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02MQ22D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02MQ24D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02MQ25D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02GQ12D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02GQ14D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02GQ23D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)
design engineersPanasonicAIG02GQ25D
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC1.9 W or less0 to +50 ℃ +32 to +122℉20 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)–20 to +60 ℃ –4 to +140℉10 to 85% RH (at +25 ℃ +77 ℉), (No dew condensation allowed)5 to 8.4 Hz amplitude: 3.5 mm 0.138 in, 8.4 to 150 Hz acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave/min.)