Human Machine Interface (HMI): GT32-E

Model List

Found 4 matches. Display 1 - 4 matches.
Part No.sort descendingData SheetCE marking directive compliancePower supplyOperating voltage rangePower consumptionPower supply unit isolation methodAmbient temperatureAmbient humidityStorage temperatureStorage humidityVibration resistanceParts Inventory
   Column active Filter
Close

Filter by CE marking directive compliance

Column active Filter
Close

Filter by Power supply

Column active Filter
Close

Filter by Operating voltage range

Column active Filter
Close

Filter by Power consumption

Column active Filter
Close

Filter by Power supply unit isolation method

Column active Filter
Close

Filter by Ambient temperature

Column active Filter
Close

Filter by Ambient humidity

Column active Filter
Close

Filter by Storage temperature

Column active Filter
Close

Filter by Storage humidity

Column active Filter
Close

Filter by Vibration resistance

 
design engineersPanasonicAIG32TQ05DE
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC7.2 W or lessTransformer isolation-20 to +60 ℃ -4 to +140 ℉
Note: Please use within a temperature range of −20 to +55 ℃ −4 to +131 ℉ when horizontally installed and vertically installed in a portrait orientation and when using battery.
10 to 90 %RH (at 25 degrees 77 degrees Fahrenheit), (No dew condensation allowed)-20 to +60 degrees -4 to +140 degrees Fahrenheit10 to 90 %RH (at 25 degrees 77 degrees Fahrenheit), (No dew condensation allowed)5 to 8.4 Hz, amplitude: 3.5 mm 0.14 in, 8.4 to 150 Hz, acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave / min.)
design engineersPanasonicAIG32MQ05DE
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC4.8 W or lessTransformer isolation-20 to +60 ℃ -4 to +140 ℉
Note: Please use within a temperature range of −20 to +55 ℃ −4 to +131 ℉ when horizontally installed and vertically installed in a portrait orientation and when using battery.
10 to 90 %RH (at 25 degrees 77 degrees Fahrenheit), (No dew condensation allowed)-20 to +60 degrees -4 to +140 degrees Fahrenheit10 to 90 %RH (at 25 degrees 77 degrees Fahrenheit), (No dew condensation allowed)5 to 8.4 Hz, amplitude: 3.5 mm 0.14 in, 8.4 to 150 Hz, acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave / min.)
design engineersPanasonicAIG32MQ03DE
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC4.8 W or lessTransformer isolation-20 to +60 ℃ -4 to +140 ℉
Note: Please use within a temperature range of −20 to +55 ℃ −4 to +131 ℉ when horizontally installed and vertically installed in a portrait orientation and when using battery.
10 to 90 %RH (at 25 degrees 77 degrees Fahrenheit), (No dew condensation allowed)-20 to +60 degrees -4 to +140 degrees Fahrenheit10 to 90 %RH (at 25 degrees 77 degrees Fahrenheit), (No dew condensation allowed)5 to 8.4 Hz, amplitude: 3.5 mm 0.14 in, 8.4 to 150 Hz, acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave / min.)
design engineersPanasonicAIG32TQ03DE
EMC Directive, RoHS Directive24 V DC21.6 to 26.4 V DC7.2 W or lessTransformer isolation-20 to +60 ℃ -4 to +140 ℉
Note: Please use within a temperature range of −20 to +55 ℃ −4 to +131 ℉ when horizontally installed and vertically installed in a portrait orientation and when using battery.
10 to 90 %RH (at 25 degrees 77 degrees Fahrenheit), (No dew condensation allowed)-20 to +60 degrees -4 to +140 degrees Fahrenheit10 to 90 %RH (at 25 degrees 77 degrees Fahrenheit), (No dew condensation allowed)5 to 8.4 Hz, amplitude: 3.5 mm 0.14 in, 8.4 to 150 Hz, acceleration 9.8 m/s2, 10 sweeps each in X, Y and Z directions (1 octave / min.)